Literature DB >> 20010394

Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies.

Jin Luo1, Luke Daines, Alexander Charalambous, Michael A Adams, Deborah J Annesley-Williams, Patricia Dolan.   

Abstract

STUDY DESIGN.: Biomechanical study of vertebroplasty in cadaver motion segments. OBJECTIVES.: To determine how the volume of injected cement influences: (a) stress distributions on fractured and adjacent vertebral bodies, (b) load-sharing between the vertebral bodies and neural arch, and (c) cement leakage. SUMMARY OF BACKGROUND DATA.: Vertebroplasty is increasingly used to treat vertebral fractures, but there are problems concerning adjacent level fracture and cement leakage, both of which may depend on the volume of injected cement. METHODS.: Nineteen thoracolumbar motion segments from 13 cadavers (42-91 years) were loaded to induce fracture. Fractured vertebrae received 2 sequential injections (VP1 and VP2) of 3.5 cm of polymethylmethacrylate cement. Before and after each intervention, motion segment stiffness was measured in compression and in bending, and "stress profilometry" was used to quantify the distribution of compressive stress in the intervertebral disc (which presses equally on fractured and adjacent vertebrae). Stress profiles were obtained by pulling a pressure transducer through the disc while the motion segment was compressed in flexed and extended postures. Stress profiles yielded the intradiscal pressure (IDP), the magnitude of stress peaks in the anterior and posterior (SPP) anulus, and the percentage of the applied compressive force resisted by the neural arch (FN). Cement leakage and vertebral body volume were quantified using water-immersion, and the percentage cement fill was estimated. RESULTS.: Bending and compressive stiffness fell by 37% and 50% respectively following fracture, and were restored only after VP2. Depending on posture, IDP fell by 59-85% after fracture whereas SPP increased by 107- 362%. VP1 restored IDP and SPP to prefracture values, and VP2 produced no further changes. Fracture increased FN from 11% to 39% in flexion, and from 33% to 59% in extension. FN was restored towards prefracture values only after VP2. Cement leakage increased after VP2 and was negatively correlated to vertebral body volume. Following VP2, increases in IDP and compressive stiffness were proportional to percentage fill. CONCLUSION.: About 3.5 cm of PMMA largely restored normal stress distributions to fractured and adjacent vertebral bodies, but 7 cm were required to restore motion segment stiffness and load-sharing between the vertebral bodies and neural arch. Cement leakage, IDP and compressive stiffness all increased with percentage fill.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20010394     DOI: 10.1097/BRS.0b013e3181b4ea1e

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  24 in total

1.  Retrospective review of procedural parameters and outcomes of percutaneous vertebroplasty in 673 patients.

Authors:  Benny S Kim; Barbara Hum; Jung Cheol Park; In Sup Choi
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

2.  [Kyphoplasty and vertebroplasty. Indications, techniques, complications and results].

Authors:  B Schmidt-Rohlfing; H Reilmann; R Pfeifer; P Kobbe; H C Pape
Journal:  Unfallchirurg       Date:  2011-05       Impact factor: 1.000

Review 3.  Volume matters: a review of procedural details of two randomised controlled vertebroplasty trials of 2009.

Authors:  Bronek Boszczyk
Journal:  Eur Spine J       Date:  2010-08-05       Impact factor: 3.134

Review 4.  [Analgesic interventions for spinal diseases].

Authors:  W Reith; U Yilmaz
Journal:  Radiologe       Date:  2011-09       Impact factor: 0.635

5.  Biomechanical comparison of vertebral augmentation with silicone and PMMA cement and two filling grades.

Authors:  Tobias L Schulte; Alexander Keiler; Felix Riechelmann; Tobias Lange; Werner Schmoelz
Journal:  Eur Spine J       Date:  2013-07-24       Impact factor: 3.134

6.  Treatment of osteoporotic vertebral compression fractures with percutaneous vertebroplasty under local anesthesia: clinical and radiological results.

Authors:  Hüseyin Balkarli; Hakan Demirtas; Mesut Kilic; Ibrahim Ozturk
Journal:  Int J Clin Exp Med       Date:  2015-09-15

7.  Percutaneous pediculoplasty for traumatic pedicle fracture. A technical case report.

Authors:  J Singh; M D Baker; P P Morris; C T Whitlow
Journal:  Interv Neuroradiol       Date:  2012-06-04       Impact factor: 1.610

8.  Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.

Authors:  Jin Luo; Michael A Adams; Patricia Dolan
Journal:  J Osteoporos       Date:  2010-06-20

9.  Surgical procedure and initial radiographic results of a new augmentation technique for vertebral compression fractures.

Authors:  Martin Thaler; Ricarda Lechner; Michael Nogler; Michaela Gstöttner; Christian Bach
Journal:  Eur Spine J       Date:  2013-01-03       Impact factor: 3.134

10.  Cement volume is the most important modifiable predictor for pain relief in BKP: results from SWISSspine, a nationwide registry.

Authors:  Christoph Röder; Bronek Boszczyk; Gosia Perler; Emin Aghayev; Fabrice Külling; Gianluca Maestretti
Journal:  Eur Spine J       Date:  2013-06-18       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.