Reduction of dose delivered to organs at risk in prostate cancer patients via image-guided radiation therapy.

Jason M Pawlowski1, Eddy S Yang, Arnold W Malcolm, Charles W Coffey, George X Ding.   

Abstract

PURPOSE: To determine whether image guidance can improve the dose delivered to target organs and organs at risk (OARs) for prostate cancer patients treated with intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: Eight prostate cancer patients were treated with IMRT to 76 Gy at 2 Gy per fraction. Daily target localization was performed via alignment of three intraprostatic fiducials and weekly kV-cone beam computed tomography (CBCT) scans. The prostate and OARs were manually contoured on each CBCT by a single physician. Daily patient setup shifts were obtained by comparing alignment of skin tattoos with the treatment position based on fiducials. Treatment fields were retrospectively applied to CBCT scans. The dose distributions were calculated using actual treatment plans (an 8-mm PTV margin everywhere except for 6-mm posteriorly) with and without image guidance shifts. Furthermore, the feasibility of margin reduction was evaluated by reducing planning margins to 4 mm everywhere except for 3 mm posteriorly.
RESULTS: For the eight treatment plans on the 56 CBCT scans, the average doses to 98% of the prostate (D98) were 102% (range, 99-104%) and 99% (range, 45-104%) with and without image guidance, respectively. Using margin reduction, the average D98s were 100% (range, 84-104%) and 92% (range, 40-104%) with and without image guidance, respectively.
CONCLUSIONS: Currently, margins used in IMRT plans are adequate to deliver a dose to the prostate with conventional patient positioning using skin tattoos or bony anatomy. The use of image guidance may facilitate significant reduction of planning margins. Future studies to assess the efficacy of decreasing margins and improvement of treatment-related toxicities are warranted. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20004528     DOI: 10.1016/j.ijrobp.2009.06.068

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  18 in total

Review 1.  Technological advances in radiation therapy for prostate cancer.

Authors:  Mehee Choi; Arthur Y Hung
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

2.  Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

Authors:  Petr Paluska; Josef Hanus; Jana Sefrova; Lucie Rouskova; Jakub Grepl; Jan Jansa; Linda Kasaova; Miroslav Hodek; Milan Zouhar; Milan Vosmik; Jiri Petera
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-05

3.  Dosimetric and volumetric effects in clinical target volume and organs at risk during postprostatectomy radiotherapy.

Authors:  Ahmed Gawish; Ahmed Ali Chughtai; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2018-10-17       Impact factor: 3.621

4.  The contribution of the cone beam Kv CT (CBKvCT) to the reduction in toxicity of prostate cancer treatment with external 3D radiotherapy.

Authors:  Antonio José Conde-Moreno; Carlos Ferrer-Albiach; Mercedes Zabaleta-Meri; Xavi J Juan-Senabre; Agustín Santos-Serra
Journal:  Clin Transl Oncol       Date:  2012-10-02       Impact factor: 3.405

5.  Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--experiments, simulation, and dosimetry study.

Authors:  Wu Liu; Jianguo Qian; Steven L Hancock; Lei Xing; Gary Luxton
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

6.  Image-guided radiotherapy of the prostate using daily CBCT: the feasibility and likely benefit of implementing a margin reduction.

Authors:  I F Maund; R J Benson; J Fairfoul; J Cook; R Huddart; A Poynter
Journal:  Br J Radiol       Date:  2014-10-29       Impact factor: 3.039

Review 7.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

8.  Dosimetric impact of organ at risk daily variation during prostate stereotactic ablative radiotherapy.

Authors:  Lynsey Devlin; David Dodds; Azmat Sadozye; Philip McLoone; Nicholas MacLeod; Carolynn Lamb; Suzanne Currie; Stefanie Thomson; Aileen Duffton
Journal:  Br J Radiol       Date:  2020-01-30       Impact factor: 3.039

Review 9.  Ultrasound Imaging in Radiation Therapy: From Interfractional to Intrafractional Guidance.

Authors:  Craig Western; Dimitre Hristov; Jeffrey Schlosser
Journal:  Cureus       Date:  2015-06-20

Review 10.  Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review.

Authors:  Kavitha Srinivasan; Mohammad Mohammadi; Justin Shepherd
Journal:  Pol J Radiol       Date:  2014-07-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.