Literature DB >> 19996761

Quantitative pulmonary perfusion magnetic resonance imaging: influence of temporal resolution and signal-to-noise ratio.

Michael Ingrisch1, Olaf Dietrich, Ulrike I Attenberger, Konstantin Nikolaou, Steven Sourbron, Maximilian F Reiser, Christian Fink.   

Abstract

PURPOSE: To investigate the influence of the contrast-to-noise ratio (CNR) and temporal resolution of 3D dynamic contrast-enhanced magnetic resonance imaging on the quantification of pulmonary perfusion parameters by means of Monte-Carlo simulations and a volunteer study.
METHODS: Quantification of perfusion parameters such as pulmonary blood flow (PBF) and pulmonary blood volume (PBV) was simulated using synthetic data with varying CNR (noise standard deviations ranging from 0% to 25% of the parenchymal signal maximum) and different temporal resolutions from 1 to 5 seconds. Simulation results were compared with perfusion measurements in 9 healthy volunteers (age: 18-31) using dynamic 3D gradient-echo sequences with different k-space acquisition schemes, resulting in different temporal resolutions of 1.1, 1.3, and 2.0 seconds per volume and varying CNR. Lung parenchyma was segmented using a semiautomatic technique, and PBF, PBV, as well as MTT were determined pixelwise using Tikhonov-regularized deconvolution with an optimized L-curve criterion.
RESULTS: The simulations showed a breakdown of the deconvolution algorithm for temporal resolutions lower than 3 s. PBF was increasingly underestimated with decreasing CNR; the temporal resolution had little influence on PBF estimates in the investigated range. PBV, on the other hand, was more dependent on the temporal resolution and showed less, but noticeable influence of the CNR. For low temporal resolutions, PBV was overestimated.In the volunteer study, no significant differences of PBF between the different sequences were found; however, PBV was underestimated by the slowest sequence, in contrast to the simulation results.
CONCLUSION: Both the mathematical simulations and volunteer measurements showed that the temporal resolution has less influence than the CNR on the quantification of PBF. On the other hand, PBV is more influenced by temporal resolution than by CNR. This indicates that the gain in measurement speed that can be obtained by modern acceleration schemes need not be invested in ultra-high temporal resolution. Instead, sequence optimization should aim for a suitable balance of sufficient CNR on the one hand, and sufficient temporal resolution on the other hand, whereas maintaining a high spatial resolution.

Entities:  

Mesh:

Year:  2010        PMID: 19996761     DOI: 10.1097/RLI.0b013e3181bc2d0c

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  15 in total

1.  Prognosis prediction of non-enhancing T2 high signal intensity lesions in glioblastoma patients after standard treatment: application of dynamic contrast-enhanced MR imaging.

Authors:  Rihyeon Kim; Seung Hong Choi; Tae Jin Yun; Soon-Tae Lee; Chul-Kee Park; Tae Min Kim; Ji-Hoon Kim; Sun-Won Park; Chul-Ho Sohn; Sung-Hye Park; Il Han Kim
Journal:  Eur Radiol       Date:  2016-06-29       Impact factor: 5.315

Review 2.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

3.  Correlation analysis of dual-energy CT iodine maps with quantitative pulmonary perfusion MRI.

Authors:  Jan Hansmann; Paul Apfaltrer; Frank G Zoellner; Thomas Henzler; Mathias Meyer; Gerald Weisser; Stefan O Schoenberg; Ulrike I Attenberger
Journal:  World J Radiol       Date:  2013-05-28

4.  Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair.

Authors:  M Weis; V Sommer; F G Zöllner; C Hagelstein; K Zahn; T Schaible; S O Schoenberg; K W Neff
Journal:  Eur Radiol       Date:  2016-04-06       Impact factor: 5.315

5.  Cardio-pulmonary MRI for detection of treatment response after a single BPA treatment session in CTEPH patients.

Authors:  Christian Schoenfeld; Jan B Hinrichs; Karen M Olsson; Martin-Alexander Kuettner; Julius Renne; Till Kaireit; Christoph Czerner; Frank Wacker; Marius M Hoeper; Bernhard C Meyer; Jens Vogel-Claussen
Journal:  Eur Radiol       Date:  2018-10-11       Impact factor: 5.315

6.  Pulmonary perfusion imaging using MRI: clinical application.

Authors:  Sebastian Ley; Julia Ley-Zaporozhan
Journal:  Insights Imaging       Date:  2011-12-29

7.  Quantitative pulmonary perfusion imaging at 3.0 T of 2-year-old children after congenital diaphragmatic hernia repair: initial results.

Authors:  F G Zöllner; K Zahn; T Schaible; S O Schoenberg; L R Schad; K W Neff
Journal:  Eur Radiol       Date:  2012-06-13       Impact factor: 5.315

8.  High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair.

Authors:  M Weidner; F G Zöllner; C Hagelstein; K Zahn; T Schaible; S O Schoenberg; L R Schad; K W Neff
Journal:  Eur Radiol       Date:  2014-07-20       Impact factor: 5.315

9.  The Added Prognostic Value of Preoperative Dynamic Contrast-Enhanced MRI Histogram Analysis in Patients with Glioblastoma: Analysis of Overall and Progression-Free Survival.

Authors:  Y S Choi; D W Kim; S-K Lee; J H Chang; S-G Kang; E H Kim; S H Kim; T H Rim; S S Ahn
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-03       Impact factor: 3.825

Review 10.  DCE-MRI in hepatocellular carcinoma-clinical and therapeutic image biomarker.

Authors:  Bang-Bin Chen; Tiffany Ting-Fang Shih
Journal:  World J Gastroenterol       Date:  2014-03-28       Impact factor: 5.742

View more