Abstract

PURPOSE: The aim of this study was to identify specific complications of locking plate fixation of proximal humerus fractures. PATIENTS AND METHODS: Seventy-three adult patients with a displaced 3- (24%) or 4-part (76%) fracture of the proximal humerus were treated over a period of 2 years under the supervision of a trauma surgeon. Fourty-four patients came back for a clinical and radiographic examinations at least 18 months after the trauma; the others were evaluated at 6 weeks and 3 and 6 months.
RESULTS: Out of the 73 patients (64.4% females, mean age of 65), 11 patients needed a second surgery and 18 were lost for follow-up after 6 months. Mean final constant score was 62.3 points. The incidence of secondary displacement was 8.2%. Nonunion rate was 5.5%, affecting the constant score (P = .018). 16.4% of the patients developed a partial necrosis of the humeral head at the latest follow-up, which influenced on the constant score (P = .029). Quality of the reduction of the greater tuberosity influenced final results (P = .037). Screw cutout rate was 13.7%, with an influence to the constant score (P = .001). A too high plate positioning influenced the constant score (P = .002).
CONCLUSION: Locked screw-plates provide more secure fixation of fractures, especially in weak bone. Complications rate remains high. Two complications are to be distinguished: 1) technical complications in plate positioning, length of the screws or secondary screw cutout strongly influence the final clinical result; and 2) specific complications related to this technology such as pseudarthrosis or plate fracture. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19995683     DOI: 10.1016/j.jse.2009.09.005

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  56 in total

1.  Open reduction and internal fixation versus hemiarthroplasty in the management of proximal humerus fractures.

Authors:  Robert Thorsness; James Iannuzzi; Katia Noyes; Stephen Kates; Ilya Voloshin
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-06

2.  Arthroscopic fixation of displaced greater tuberosity fracture of the proximal humerus.

Authors:  Sang-Uk Lee; Changhoon Jeong; Il-Jung Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

Review 3.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 4.  Surgical versus conservative treatment for displaced proximal humeral fractures in elderly patients: a meta-analysis.

Authors:  Tao Fu; Chengyan Xia; Zonghuan Li; Hua Wu
Journal:  Int J Clin Exp Med       Date:  2014-12-15

5.  Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?

Authors:  Weixiong Liao; Hao Zhang; Zhongli Li; Ji Li
Journal:  Clin Orthop Relat Res       Date:  2016-01-04       Impact factor: 4.176

6.  Treatment of three- and four-part proximal humeral fractures with locking proximal humerus plate.

Authors:  Jing-Cheng Sun; Yu-Lin Li; Guang-Zhi Ning; Qiang Wu; Shi-Qing Feng
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-12

7.  Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Authors:  Ben Ockert; Vera Pedersen; Lucas Geyer; Stefan Wirth; Wolf Mutschler; Stefan Grote
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

8.  Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.

Authors:  Stefan Quadlbauer; Georg J Hofmann; Martin Leixnering; Rudolf Rosenauer; Thomas Hausner; Jürgen Reichetseder
Journal:  Int Orthop       Date:  2018-02-13       Impact factor: 3.075

9.  Treatment of proximal and middle one-third humeral fractures with lateral distal tibial helical plate.

Authors:  Liang Zhang; Lin-Wei Chen; Wen-Jie Zhang; Chun-Ming Zhao; Bo Huang; Qing Yu; Bin Ni
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-12-09

10.  Treatment for proximal humeral fractures with percutaneous plating: our first results.

Authors:  D Imarisio; A Trecci; L Sabatini; R Scagnelli
Journal:  Musculoskelet Surg       Date:  2013-04-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.