Literature DB >> 19994523

Treatment planning for volumetric modulated arc therapy.

James L Bedford1.   

Abstract

PURPOSE: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented.
METHODS: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality.
RESULTS: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case.
CONCLUSIONS: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

Mesh:

Year:  2009        PMID: 19994523     DOI: 10.1118/1.3240488

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  Inverse planning for four-dimensional (4D) volumetric modulated arc therapy.

Authors:  Yunzhi Ma; Daniel Chang; Paul Keall; Yiaoqin Xie; Jae-yoon Park; Tae-suk Suh; Lei Xing
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; Henry C Mandeville; A Rollo Moore; Liam C Welsh; Frank H Saran; James L Bedford
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

3.  Improving IMRT-plan quality with MLC leaf position refinement post plan optimization.

Authors:  Ying Niu; Guowei Zhang; Barry L Berman; William C Parke; Byongyong Yi; Cedric X Yu
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

4.  Optimization approaches to volumetric modulated arc therapy planning.

Authors:  Jan Unkelbach; Thomas Bortfeld; David Craft; Markus Alber; Mark Bangert; Rasmus Bokrantz; Danny Chen; Ruijiang Li; Lei Xing; Chunhua Men; Simeon Nill; Dávid Papp; Edwin Romeijn; Ehsan Salari
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

5.  IMRT and IGRT in head and neck cancer: Have we delivered what we promised?

Authors:  Gupta Tejpal; Agarwal Jaiprakash; Bannerjee Susovan; Sarbani Ghosh-Laskar; Vedang Murthy; Ashwini Budrukkar
Journal:  Indian J Surg Oncol       Date:  2010-11-21

6.  Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy.

Authors:  S Clemente; M Cozzolino; C Oliviero; A Fiorentino; C Chiumento; V Fusco
Journal:  Clin Transl Oncol       Date:  2013-05-04       Impact factor: 3.405

7.  A dosimetric analysis of volumetric-modulated arc radiotherapy with jaw width restriction vs 7 field intensity-modulated radiotherapy for definitive treatment of cervical cancer.

Authors:  B Huang; Z Fang; Y Huang; P Lin; Z Chen
Journal:  Br J Radiol       Date:  2014-05-16       Impact factor: 3.039

8.  Volumetric Modulated Arc Therapy (VMAT) make a difference in retro-orbital irradiation treatment of patients with bilateral Graves' ophthalmopathy. Comparative analysis of dosimetric parameters from different radiation techniques.

Authors:  Iñigo San-Miguel; Ruth Carmona; Luis Luque; Raquel Cabrera; Marta Lloret; Francisco Rutllan; Pedro Carlos Lara
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-07

9.  A comprehensive comparison of IMRT and VMAT plan quality for prostate cancer treatment.

Authors:  Enzhuo M Quan; Xiaoqiang Li; Yupeng Li; Xiaochun Wang; Rajat J Kudchadker; Jennifer L Johnson; Deborah A Kuban; Andrew K Lee; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-07-15       Impact factor: 7.038

10.  Volumetric modulated arc therapy planning for distal oesophageal malignancies.

Authors:  M A Hawkins; J L Bedford; A P Warrington; D M Tait
Journal:  Br J Radiol       Date:  2011-03-22       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.