Literature DB >> 1998283

Doppler echocardiographic comparison of the Carpentier and Duran anuloplasty rings versus no ring after mitral valve repair for mitral regurgitation.

B Unger-Graeber1, R T Lee, M S Sutton, M Plappert, J J Collins, L H Cohn.   

Abstract

To compare the hemodynamic results of different anuloplasty techniques of primary valve repair for mitral regurgitation, 122 patients were prospectively studied with Doppler echocardiograms 5 to 10 days after operation. Seventy-seven patients had mitral valve prolapse, 27 had coronary artery disease, 13 patients had rheumatic mitral valve lesions and 5 patients had infective endocarditis. Forty-eight patients received the flexible Duran ring, 46 received the more rigid Carpentier ring and 28 patients received no ring. Doppler echocardiography demonstrated a significant decrease in mitral valve area estimated by the pressure half-time method in patients who received either a Carpentier (2.6 +/- 0.8 cm2) or Duran ring (2.8 +/- 0.8 cm2) when compared with patients who received no ring (3.2 +/- 0.7 cm2) (p = 0.01). No significant differences were observed for peak transmitral diastolic velocity, peak transmitral diastolic gradient, or the grade of mitral regurgitation by color flow Doppler mapping between patients with and without rings. The etiology of mitral disease and concomitant surgical procedures accompanying mitral valve repair did not significantly influence mitral valve area, peak velocity or peak gradient. These data suggest that Carpentier and Duran rings decrease the hemodynamic mitral valve area; however, the decrease in valve area is small and not associated with a clinically important increase in transvalvular gradient.

Entities:  

Mesh:

Year:  1991        PMID: 1998283     DOI: 10.1016/0002-9149(91)90014-c

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Anterior mitral leaflet curvature during the cardiac cycle in the normal ovine heart.

Authors:  John-Peder Escobar Kvitting; Wolfgang Bothe; Serdar Göktepe; Manuel K Rausch; Julia C Swanson; Ellen Kuhl; Neil B Ingels; D Craig Miller
Journal:  Circulation       Date:  2010-10-11       Impact factor: 29.690

2.  The Carpentier-Edwards Classic and Physio Annuloplasty Rings in Repair of Degenerative Mitral Valve Disease: A Retrospective Study.

Authors:  Abubakari I Sidiki; Alexandr G Faybushevich; Alexandr N Lishchuk; Alexandr N Koltunov; Ekaterina A Roshchina
Journal:  J Saudi Heart Assoc       Date:  2020-05-20

3.  Echocardiographic evaluation of anuloplasty rings. Comparison of continuity equation and pressure half-time methods.

Authors:  S Wilansky; S L Martin; C M Gaos; B S Jin; R J Hall; D A Cooley
Journal:  Tex Heart Inst J       Date:  1994

4.  Mid-term results of mitral valve repair using flexible bands versus complete rings in patients with degenerative mitral valve disease: a prospective, randomized study.

Authors:  Alexandr V Bogachev-Prokophiev; Alexandr V Afanasyev; Sergei I Zheleznev; Vladimir M Nazarov; Ravil M Sharifulin; Alexandr M Karaskov
Journal:  J Cardiothorac Surg       Date:  2017-12-13       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.