Literature DB >> 19964313

Motion-compensated temporal summation of cardiac gated SPECT images using a deformable mesh model.

Thibault Marin1, Miles N Wernick, Yongyi Yang, Jovan G Brankov.   

Abstract

We propose a motion-compensated non-rigid summation method for noise reduction in cardiac gated SPECT. This approach generates a static SPECT image containing counts from all frames of the gated sequence while accounting for heart motion to avoid motion-blur artifact. Static cardiac images typically suffer from heart motion occurring during acquisition which introduces the so-called motion blur artifact. Gated acquisitions, on the other hand, are characterized by lower counts in each individual frame, thus resulting in noisy images. Methods have been proposed to sum the gated sequence along the time dimension while accounting for heart motion, but they do not account for partial volume effect, manifested by an intensity increase as the myocardium contracts. The partial volume effect, a useful diagnostic feature has to be accounted for during both motion estimation and temporal summation. The proposed method relies on a deformable mesh model to estimate heart motion while accounting for the partial volume effect. The estimated motion is further used to perform non-rigid summation along the time dimension. We show that the proposed method yields visual improvement on clinical data. In addition, quantitative evaluation from phantom studies proves that the proposed method achieves better noise reduction performance than available clinical techniques.

Entities:  

Mesh:

Year:  2009        PMID: 19964313      PMCID: PMC2810283          DOI: 10.1109/IEMBS.2009.5333693

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  14 in total

1.  "Motion-frozen" display and quantification of myocardial perfusion.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; Cigdem Akincioglu; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-07       Impact factor: 10.057

2.  Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling.

Authors:  Jovan G Brankov; Yongyi Yang; Miles N Wernick
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  Measurement of strain in the left ventricle during diastole with cine-MRI and deformable image registration.

Authors:  Alexander I Veress; Grant T Gullberg; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2005-12       Impact factor: 2.097

4.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

5.  Fully 4D motion-compensated reconstruction of cardiac SPECT images.

Authors:  Erwan Gravier; Yongyi Yang; Michael A King; Mingwu Jin
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

6.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  A Monte Carlo program for the simulation of scintillation camera characteristics.

Authors:  M Ljungberg; S E Strand
Journal:  Comput Methods Programs Biomed       Date:  1989-08       Impact factor: 5.428

8.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

9.  Myocardial perfusion SPECT reconstruction: receiver operating characteristic comparison of CAD detection accuracy of filtered backprojection reconstruction with all of the clinical imaging information available to readers and solely stress slices iteratively reconstructed with combined compensation.

Authors:  P Hendrik Pretorius; Michael A King; Howard C Gifford; Seth T Dahlberg; Frederick Spencer; Ellen Simon; Jason Rashkin; Naomi Botkin; William Berndt; Manoj V Narayanan; Jeffrey A Leppo
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

10.  Motion-frozen myocardial perfusion SPECT improves detection of coronary artery disease in obese patients.

Authors:  Yasuyuki Suzuki; Piotr J Slomka; Arik Wolak; Muneo Ohba; Shoji Suzuki; Ling De Yang; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.