Literature DB >> 16502662

Measurement of strain in the left ventricle during diastole with cine-MRI and deformable image registration.

Alexander I Veress1, Grant T Gullberg, Jeffrey A Weiss.   

Abstract

The assessment of regional heart wall motion (local strain) can localize ischemic myocardial disease, evaluate myocardial viability, and identify impaired cardiac function due to hypertrophic or dilated cardiomyopathies. The objectives of this research were to develop and validate a technique known as hyperelastic warping for the measurement of local strains in the left ventricle from clinical cine-magnetic resonance imaging (MRI) image datasets. The technique uses differences in image intensities between template (reference) and target (loaded) image datasets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target image. To validate the technique, MRI image datasets representing two deformation states of a left ventricle were created such that the deformation map between the states represented in the images was known. A beginning diastolic cine-MRI image dataset from a normal human subject was defined as the template. A second image dataset (target) was created by mapping the template image using the deformation results obtained from a forward FE model of diastolic filling. Fiber stretch and strain predictions from hyperelastic warping showed good agreement with those of the forward solution (R2=0.67 stretch, R2=0.76 circumferential strain, R2=0.75 radial strain, and R2=0.70 in-plane shear). The technique had low sensitivity to changes in material parameters (deltaR2= -0.023 fiber stretch, deltaR2=-0.020 circumferential strain, deltaR2=-0.005 radial strain, and deltaR2=0.0125 shear strain with little or no change in rms error), with the exception of changes in bulk modulus of the material. The use of an isotropic hyperelastic constitutive model in the warping analyses degraded the predictions of fiber stretch. Results were unaffected by simulated noise down to a signal-to-noise ratio (SNR) of 4.0 (deltaR2= -0.032 fiber stretch, deltaR2=-0.023 circumferential strain, deltaR2=-0.04 radial strain, and deltaAR2=0.0211 shear strain with little or no increase in rms error). This study demonstrates that warping in conjunction with cine-MRI imaging can be used to determine local ventricular strains during diastole.

Entities:  

Mesh:

Year:  2005        PMID: 16502662     DOI: 10.1115/1.2073677

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  29 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  Dictionary-Driven Ischemia Detection From Cardiac Phase-Resolved Myocardial BOLD MRI at Rest.

Authors:  Marco Bevilacqua; Rohan Dharmakumar; Sotirios A Tsaftaris
Journal:  IEEE Trans Med Imaging       Date:  2015-08-19       Impact factor: 10.048

Review 3.  Verification, validation and sensitivity studies in computational biomechanics.

Authors:  Andrew E Anderson; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-06       Impact factor: 1.763

Review 4.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

5.  Optimization of nonlinear hyperelastic coefficients for foot tissues using a magnetic resonance imaging deformation experiment.

Authors:  Marc Petre; Ahmet Erdemir; Vassilis P Panoskaltsis; Thomas A Spirka; Peter R Cavanagh
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

6.  Motion-compensated temporal summation of cardiac gated SPECT images using a deformable mesh model.

Authors:  Thibault Marin; Miles N Wernick; Yongyi Yang; Jovan G Brankov
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

7.  Intramyocardial strain estimation from cardiac cine MRI.

Authors:  Ahmed Elnakib; Garth M Beache; Georgy Gimel'farb; Ayman El-Baz
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-27       Impact factor: 2.924

8.  A Plugin Framework for Extending the Simulation Capabilities of FEBio.

Authors:  Steve A Maas; Steven A LaBelle; Gerard A Ateshian; Jeffrey A Weiss
Journal:  Biophys J       Date:  2018-09-26       Impact factor: 4.033

9.  Finite-Element Extrapolation of Myocardial Structure Alterations Across the Cardiac Cycle in Rats.

Authors:  Arnold David Gomez; David A Bull; Edward W Hsu
Journal:  J Biomech Eng       Date:  2015-10       Impact factor: 2.097

10.  Accurate high-resolution measurements of 3-D tissue dynamics with registration-enhanced displacement encoded MRI.

Authors:  Arnold D Gomez; Samer S Merchant; Edward W Hsu
Journal:  IEEE Trans Med Imaging       Date:  2014-03-14       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.