Literature DB >> 19953515

Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection.

Rafael L O'Halloran1, James H Holmes, Yu-Chien Wu, Andrew Alexander, Sean B Fain.   

Abstract

An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19953515      PMCID: PMC2859717          DOI: 10.1002/mrm.22158

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient.

Authors:  X J Chen; H E Möller; M S Chawla; G P Cofer; B Driehuys; L W Hedlund; G A Johnson
Journal:  Magn Reson Med       Date:  1999-10       Impact factor: 4.668

2.  Lung air spaces: MR imaging evaluation with hyperpolarized 3He gas.

Authors:  E E de Lange; J P Mugler; J R Brookeman; J Knight-Scott; J D Truwit; C D Teates; T M Daniel; P L Bogorad; G D Cates
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

3.  Relationships between diffusion tensor and q-space MRI.

Authors:  Peter J Basser
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

4.  The mechanism of lung volume change during mechanical ventilation.

Authors:  D E Carney; C E Bredenberg; H J Schiller; A L Picone; U G McCann; L A Gatto; G Bailey; M Fillinger; G F Nieman
Journal:  Am J Respir Crit Care Med       Date:  1999-11       Impact factor: 21.405

5.  Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion.

Authors:  X J Chen; L W Hedlund; H E Möller; M S Chawla; R R Maronpot; G A Johnson
Journal:  Proc Natl Acad Sci U S A       Date:  2000-10-10       Impact factor: 11.205

6.  Definition of displacement probability and diffusion time in q-space magnetic resonance measurements that use finite-duration diffusion-encoding gradients.

Authors:  Nicolas F Lori; Thomas E Conturo; Denis Le Bihan
Journal:  J Magn Reson       Date:  2003-12       Impact factor: 2.229

7.  Highly constrained backprojection for time-resolved MRI.

Authors:  C A Mistretta; O Wieben; J Velikina; W Block; J Perry; Y Wu; K Johnson; Y Wu
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

8.  Hyperpolarized 3He apparent diffusion coefficient MRI of the lung: reproducibility and volume dependency in healthy volunteers and patients with emphysema.

Authors:  Sandra Diaz; Ingrid Casselbrant; Eeva Piitulainen; Goran Pettersson; Peter Magnusson; Barry Peterson; Per Wollmer; Peter Leander; Olle Ekberg; Per Akeson
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

9.  Structure of the human respiratory acinus.

Authors:  J P Schreider; O G Raabe
Journal:  Am J Anat       Date:  1981-11

10.  Early emphysematous changes in asymptomatic smokers: detection with 3He MR imaging.

Authors:  Sean B Fain; Shilpa R Panth; Michael D Evans; Andrew L Wentland; James H Holmes; Frank R Korosec; Matthew J O'Brien; Harvey Fountaine; Thomas M Grist
Journal:  Radiology       Date:  2006-06       Impact factor: 11.105

View more
  6 in total

1.  Multiple-exchange-time xenon polarization transfer contrast (MXTC) MRI: initial results in animals and healthy volunteers.

Authors:  Isabel Dregely; Iulian C Ruset; Jaime F Mata; Jeffrey Ketel; Steve Ketel; Jan Distelbrink; Talissa A Altes; John P Mugler; G Wilson Miller; F William Hersman; Kai Ruppert
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

2.  Measurement of lung airways in three dimensions using hyperpolarized helium-3 MRI.

Authors:  Eric T Peterson; Jionghan Dai; James H Holmes; Sean B Fain
Journal:  Phys Med Biol       Date:  2011-04-27       Impact factor: 3.609

3.  Pulmonary 3He magnetic resonance imaging of childhood asthma.

Authors:  Robert V Cadman; Robert F Lemanske; Michael D Evans; Daniel J Jackson; James E Gern; Ronald L Sorkness; Sean B Fain
Journal:  J Allergy Clin Immunol       Date:  2012-12-11       Impact factor: 10.793

Review 4.  Hyperpolarized 129Xe MRI of the human lung.

Authors:  John P Mugler; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

Review 5.  Functional imaging of the lungs with gas agents.

Authors:  Stanley J Kruger; Scott K Nagle; Marcus J Couch; Yoshiharu Ohno; Mitchell Albert; Sean B Fain
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

Review 6.  In vivo methods and applications of xenon-129 magnetic resonance.

Authors:  Helen Marshall; Neil J Stewart; Ho-Fung Chan; Madhwesha Rao; Graham Norquay; Jim M Wild
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2020-12-09       Impact factor: 9.795

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.