Literature DB >> 16714465

Early emphysematous changes in asymptomatic smokers: detection with 3He MR imaging.

Sean B Fain1, Shilpa R Panth, Michael D Evans, Andrew L Wentland, James H Holmes, Frank R Korosec, Matthew J O'Brien, Harvey Fountaine, Thomas M Grist.   

Abstract

PURPOSE: To prospectively compare apparent diffusion coefficient (ADC) measurements derived from diffusion-weighted hyperpolarized helium 3 (3He) magnetic resonance (MR) imaging with functional and structural findings using spirometric tests and thin-section computed tomography (CT) of the lungs in asymptomatic smokers and healthy nonsmokers of similar age.
MATERIALS AND METHODS: All studies were HIPAA compliant and were approved by the institutional review board. Informed consent was obtained. Ventilation and diffusion-weighted 3He MR images were obtained in healthy subjects: 11 smokers (five women, six men; mean age, 47 years+/-18 [standard deviation]; range, 23-73 years) and eight nonsmokers (<100 cigarettes in lifetime) (four women, four men; mean age, 46 years+/-16; range, 23-69 years). Mean ADC values for smokers and nonsmokers were compared with spirometric values, diffusing capacity of the lung for carbon monoxide (Dlco), age, and pack-years with Spearman rank correlation coefficient (rs) and multiple linear regression analysis. Mean ADC value and thin-section CT emphysema index of relative area less than -950 HU (RA950) were compared on a regional basis by using linear mixed-effect models.
RESULTS: Mean ADC values and number of pack-years were significantly correlated (rs=0.60; 95% confidence interval (CI): 0.21, 1.00; P=.007); relationship remained significant after adjustment for age (P=.003). Dlco was strongly correlated with pack-years (rs=-0.63; 95% CI: -0.97, -0.29; P=.004). Negative correlations between mean ADC values and percentage predicted Dlco (rs=-0.79; 95% CI: -0.93, -0.64; P<.001) and the ratio of forced expiratory volume in 1 second to forced vital capacity (rs=-0.72; 95% CI: -0.92, -0.52; P=.001) were statistically significant. Correlations between spirometric values or RA950 and number of pack-years were not significant (.05 level).
CONCLUSION: Correlations between mean ADC values and pulmonary function test measurements for diagnosing emphysema, especially Dlco, were statistically significant. Copyright (c) RSNA, 2006.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16714465     DOI: 10.1148/radiol.2393050111

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  65 in total

Review 1.  Lung imaging in asthmatic patients: the picture is clearer.

Authors:  Mario Castro; Sean B Fain; Eric A Hoffman; David S Gierada; Serpil C Erzurum; Sally Wenzel
Journal:  J Allergy Clin Immunol       Date:  2011-06-02       Impact factor: 10.793

2.  Measurement of hyperpolarized gas diffusion at very short time scales.

Authors:  Michael Carl; G Wilson Miller; John P Mugler; Scott Rohrbaugh; William A Tobias; Gordon D Cates
Journal:  J Magn Reson       Date:  2007-09-15       Impact factor: 2.229

Review 3.  Functional imaging: CT and MRI.

Authors:  Edwin J R van Beek; Eric A Hoffman
Journal:  Clin Chest Med       Date:  2008-03       Impact factor: 2.878

4.  Helium-3 diffusion MR imaging of the human lung over multiple time scales.

Authors:  John P Mugler; Chengbo Wang; G Wilson Miller; Gordon D Cates; Jaime F Mata; James R Brookeman; Eduard E de Lange; Talissa A Altes
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

5.  A robust method for estimating regional pulmonary parameters in presence of noise.

Authors:  Richard A Guyer; Michael D Hellman; Kiarash Emami; Stephen Kadlecek; Robert V Cadman; Jiangsheng Yu; Vahid Vadhat; Masaru Ishii; John MacDuffie Woodburn; Michelle Law; Rahim R Rizi
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

6.  Lung injury induced by secondhand smoke exposure detected with hyperpolarized helium-3 diffusion MR.

Authors:  Chengbo Wang; John P Mugler; Eduard E de Lange; James T Patrie; Jaime F Mata; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

7.  Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection.

Authors:  Rafael L O'Halloran; James H Holmes; Yu-Chien Wu; Andrew Alexander; Sean B Fain
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

8.  Pulmonary 3He magnetic resonance imaging of childhood asthma.

Authors:  Robert V Cadman; Robert F Lemanske; Michael D Evans; Daniel J Jackson; James E Gern; Ronald L Sorkness; Sean B Fain
Journal:  J Allergy Clin Immunol       Date:  2012-12-11       Impact factor: 10.793

9.  Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease.

Authors:  Rohan S Virgincar; Zackary I Cleveland; S Sivaram Kaushik; Matthew S Freeman; John Nouls; Gary P Cofer; Santiago Martinez-Jimenez; Mu He; Monica Kraft; Jan Wolber; H Page McAdams; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2012-10-13       Impact factor: 4.044

10.  Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Thorsten A Bley; Christopher J Francois; Julia V Velikina; Ronald L Sorkness; William W Busse; Sean B Fain
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.