Literature DB >> 19949261

The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system.

T Takakura1, T Mizowaki, M Nakata, S Yano, T Fujimoto, Y Miyabe, M Nakamura, M Hiraoka.   

Abstract

The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 +/- 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 +/- 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 +/- 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

Entities:  

Mesh:

Year:  2010        PMID: 19949261     DOI: 10.1088/0031-9155/55/1/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Accuracy of positional correction for the floor-mounted kV X-ray IGRT system in angled couch positions.

Authors:  Satoshi Koubuchi; Toru Takakura; Mitsuhiro Nakamura; Takashi Mizowaki; Manabu Nakata; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2014-06-13

2.  A Systematic Analysis of Errors in Target Localization and Treatment Delivery for Stereotactic Radiosurgery Using 2D/3D Image Registration.

Authors:  Hao Xu; Stephen Brown; Indrin J Chetty; Ning Wen
Journal:  Technol Cancer Res Treat       Date:  2016-08-31

3.  Five-year outcomes following hypofractionated stereotactic radiotherapy delivered in five fractions for acoustic neuromas: the mean cochlear dose may impact hearing preservation.

Authors:  Zhiping Chen; Keiichi Takehana; Takashi Mizowaki; Megumi Uto; Kengo Ogura; Katsuyuki Sakanaka; Yoshiki Arakawa; Yohei Mineharu; Yuki Miyabe; Nobutaka Mukumoto; Susumu Miyamoto; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2018-03-19       Impact factor: 3.402

4.  Quality and safety in stereotactic radiosurgery and stereotactic body radiation therapy: can more be done?

Authors:  Timothy D Solberg; Paul M Medin
Journal:  J Radiosurg SBRT       Date:  2011

5.  Outcomes of hypofractionated stereotactic radiotherapy for metastatic brain tumors with high risk factors.

Authors:  Kengo Ogura; Takashi Mizowaki; Masakazu Ogura; Katsuyuki Sakanaka; Yoshiki Arakawa; Susumu Miyamoto; Masahiro Hiraoka
Journal:  J Neurooncol       Date:  2012-06-20       Impact factor: 4.130

6.  Intra-fraction motion gating during frameless Gamma Knife® Icon™ therapy: The relationship between cone beam CT assessed intracranial anatomy displacement and infrared-tracked nose marker displacement.

Authors:  Gavin Wright; Jannie Schasfoort; Natalie Harrold; Paul Hatfield; Peter Bownes
Journal:  J Radiosurg SBRT       Date:  2019

7.  Frame and frameless linear accelerator-based radiosurgery for idiopathic trigeminal neuralgia.

Authors:  Allan Y Chen; Yen Hsieh; Steffanie McNair; Qijuan Li; Kevin Y Xu; Conrad Pappas
Journal:  J Radiosurg SBRT       Date:  2015

8.  Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery.

Authors:  Matthias Guckenberger; Johannes Roesch; Kurt Baier; Reinhart A Sweeney; Michael Flentje
Journal:  Radiat Oncol       Date:  2012-04-24       Impact factor: 3.481

9.  Accuracy of image guidance using free-breathing cone-beam computed tomography for stereotactic lung radiotherapy.

Authors:  Takeshi Kamomae; Hajime Monzen; Shinichi Nakayama; Rika Mizote; Yuuichi Oonishi; Soichiro Kaneshige; Takashi Sakamoto
Journal:  PLoS One       Date:  2015-05-08       Impact factor: 3.240

10.  Analysis of translational errors in frame-based and frameless cranial radiosurgery using an anthropomorphic phantom.

Authors:  Taynná Vernalha Rocha Almeida; Arno Lotar Cordova Junior; Pedro Argolo Piedade; Cintia Mara da Silva; Priscila Marins; Cristiane Maria Almeida; Gabriela R Baseggio Brincas; Danyel Scheidegger Soboll
Journal:  Radiol Bras       Date:  2016 Mar-Apr
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.