Literature DB >> 1994410

Interstitial lung disease: impact of postprocessing in digital storage phosphor imaging.

C M Schaefer1, R Greene, H J Llewellyn, H E Mrose, E A Pile-Spellman, J R Rubens, S R Lindemann.   

Abstract

The ability to resolve the fine linear structures of interstitial lung disease is one measure of the limiting performance characteristics of an imaging system. Conventional screen-film radiography was compared with six algorithms of isodose storage phosphor digital radiography (0.2-mm x 10-bit pixel matrix) in the detection of interstitial lung abnormality documented by means of computed tomography in 40 patients with abnormalities and 25 healthy control subjects. Performance was evaluated with an analysis of variance (the Fisher paired comparison test; P less than .05) of the average receiver operating characteristic area of 2,730 observations by six readers. The moderately and the more markedly high-frequency edge-enhanced algorithms of storage phosphor digital radiographs were equivalent in performance to screen-film radiography. The default mode, low- and medium-frequency edge-enhanced algorithms, and gray scale reversed mode of storage phosphor digital radiography were inferior to screen-film radiography. The authors conclude that high-frequency edge-enhanced algorithms can perform as well as screen-film radiography in the detection of interstitial disease.

Entities:  

Mesh:

Year:  1991        PMID: 1994410     DOI: 10.1148/radiology.178.3.1994410

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Enhancement of chest images by automatic adaptive spatial filtering.

Authors:  M Souto; J Correa; P G Tahoces; D Tucker; K S Malagari; J J Vidal; R G Fraser
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 2.  Chest imaging within the radiology department by means of photostimulable phosphor computed radiography: a review.

Authors:  H Blume; R G Jost
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

3.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

4.  Radiology services for remote communities: cost minimisation study of telemedicine.

Authors:  P A Halvorsen; I S Kristiansen
Journal:  BMJ       Date:  1996-05-25

5.  Unsharp masking of low-dosed digital luminescence radiographs: results of a receiver operating characteristics analysis.

Authors:  R D Müller; M Voss; H Hirche; B Buddenbrock; V John; E Bosch
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

6.  Detection of interstitial lung abnormalities on picture archive and communication system video monitors.

Authors:  T L Washowich; S C Williams; L A Richardson; G E Simmons; N V Dao; T W Allen; G C Hammet; M J Morris
Journal:  J Digit Imaging       Date:  1997-02       Impact factor: 4.056

7.  Digital chest radiography: clinical aspects.

Authors:  U Tylén
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

8.  Diagnostic usefulness of chest computed radiography--film versus cathode-ray tube images.

Authors:  T Ishigaki; S Sakuma; T Endo; M Ikeda
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

9.  Interpretation of subtle interstitial chest abnormalities: conventional radiography versus high-resolution storage-phosphor radiography--a preliminary study.

Authors:  J Ikezoe; N Kohno; S Kido; N Takeuchi; T Johkoh; J Arisawa; T Kozuka
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.