The validity of wireless iButtons and thermistors for human skin temperature measurement.

A D Harper Smith1, D R Crabtree, J L J Bilzon, N P Walsh.   

Abstract

Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons and thermistors monitored temperature in a controlled water bath (range: 10-40 degrees C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 degrees C, 20 degrees C and 30 degrees C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows. Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 degrees C for iButtons and +0.045 degrees C for thermistors. Upon calibration correction the mean bias for iButtons and thermistors was not significantly different from zero bias. Interestingly, a typical error of the estimate of iButtons (0.043 degrees C) was 1.5 times less than that of thermistors (0.062 degrees C), demonstrating iButtons' lower random error. Investigation 2: the offset between iButton and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons and thermistors during resting trials ranged from 0.261 degrees C to 1.356 degrees C. Mean temperature differences between iButtons and thermistors during exercise were 0.989 degrees C (ambient temperature = 10 degrees C), 0.415 degrees C (ambient temperature = 20 degrees C) and 0.318 degrees C (ambient temperature = 30 degrees C). Observed error estimates were within the acceptable limits for the skin temperature method comparison, with typical errors <0.3 degrees C, correlation coefficients >0.9 and CV <1% under all conditions. These findings indicate that wireless iButtons provide a valid alternative for human skin temperature measurement during laboratory and field investigations particularly when skin temperature measurement using other currently available methods may prove problematic.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19940348     DOI: 10.1088/0967-3334/31/1/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  31 in total

1.  Three nights of sleep deprivation does not alter thermal strain during exercise in the heat.

Authors:  Jonathan P Moore; Adam D Harper Smith; Umberto Di Felice; Neil P Walsh
Journal:  Eur J Appl Physiol       Date:  2013-06-13       Impact factor: 3.078

2.  Bioharness(™) multivariable monitoring device: part. I: validity.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

3.  Field based reliability and validity of the bioharness™ multivariable monitoring device.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew C S Mitchell; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

4.  Repeat work bouts increase thermal strain for Australian firefighters working in the heat.

Authors:  Anthony Walker; Christos Argus; Matthew Driller; Ben Rattray
Journal:  Int J Occup Environ Health       Date:  2015-04-07

Review 5.  Partitional calorimetry.

Authors:  Matthew N Cramer; Ollie Jay
Journal:  J Appl Physiol (1985)       Date:  2018-11-29

6.  Effect of ambient temperature and attachment method on surface temperature measurements.

Authors:  Agnes Psikuta; Reto Niedermann; René M Rossi
Journal:  Int J Biometeorol       Date:  2013-05-19       Impact factor: 3.787

7.  Fine-tuning of eTRPM8 expression and activity conditions keratinocyte fate.

Authors:  Gabriel Bidaux; Anne-Sophie Borowiec; Natalia Prevarskaya; Dmitri Gordienko
Journal:  Channels (Austin)       Date:  2016-03-25       Impact factor: 2.581

8.  Epidermal TRPM8 channel isoform controls the balance between keratinocyte proliferation and differentiation in a cold-dependent manner.

Authors:  Gabriel Bidaux; Anne-sophie Borowiec; Dmitri Gordienko; Benjamin Beck; George G Shapovalov; Loïc Lemonnier; Matthieu Flourakis; Matthieu Vandenberghe; Christian Slomianny; Etienne Dewailly; Philippe Delcourt; Emilie Desruelles; Abigaël Ritaine; Renata Polakowska; Jean Lesage; Mounia Chami; Roman Skryma; Natalia Prevarskaya
Journal:  Proc Natl Acad Sci U S A       Date:  2015-06-15       Impact factor: 11.205

9.  Improving the thermal, radial, and temporal accuracy of the analytical ultracentrifuge through external references.

Authors:  Rodolfo Ghirlando; Andrea Balbo; Grzegorz Piszczek; Patrick H Brown; Marc S Lewis; Chad A Brautigam; Peter Schuck; Huaying Zhao
Journal:  Anal Biochem       Date:  2013-05-24       Impact factor: 3.365

10.  Improved measurement of the rotor temperature in analytical ultracentrifugation.

Authors:  Huaying Zhao; Andrea Balbo; Howard Metger; Robert Clary; Rodolfo Ghirlando; Peter Schuck
Journal:  Anal Biochem       Date:  2014-02-14       Impact factor: 3.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.