Revision total knee arthroplasty for failed unicompartmental replacement.

D E Padgett1, S H Stern, J N Insall.   

Abstract

The results in nineteen patients (twenty-one knees) who had a failed unicompartmental knee replacement followed by a revision total knee arthroplasty were evaluated. There were twelve excellent, four good, one fair, and two poor results. The interval between the unicompartmental replacement and the revision total knee arthroplasty ranged from eight months to eight years. At the time of the revision, a major osseous defect was found in sixteen knees (76 per cent). The duration of follow-up after the revision ranged from two to ten years. At the most recent follow-up examination, radiographs revealed at least one radiolucent line in thirteen knees (62 per cent). The technical difficulties associated with the revision operation are evidence that unicondylar arthroplasty is not a conservative procedure that allows a total knee arthroplasty to be done easily later. The results also do not support the argument that a revision performed after failure of a unicondylar arthroplasty is less technically demanding than one performed after a failed primary total knee arthroplasty.

Entities:  

Mesh:

Year:  1991        PMID: 1993713

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  30 in total

Review 1.  [Revision of unicompartmental knee arthroplasty].

Authors:  S Kirschner; J Lützner; S Fickert; K-P Günther
Journal:  Orthopade       Date:  2006-02       Impact factor: 1.087

2.  Early failure of a mobile-bearing unicompartmental knee replacement.

Authors:  Mateen H Arastu; J Vijayaraghavan; H Chissell; J B Hull; J H Newman; J R Robinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-31       Impact factor: 4.342

3.  Revision technique for failed unicompartmental knee arthroplasty.

Authors:  L Barba
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12

4.  Lateral tibial plateau autograft in revision surgery for failed medial unicompartmental knee arthroplasty.

Authors:  Simone Cerciello; Brent Joseph Morris; Sebastien Lustig; Enrico Visonà; Giuliano Cerciello; Katia Corona; Philippe Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-04-24       Impact factor: 4.342

5.  Onlay tibial implants appear to provide superior clinical results in robotic unicompartmental knee arthroplasty.

Authors:  Brian P Gladnick; Denis Nam; Saker Khamaisy; Sophia Paul; Andrew D Pearle
Journal:  HSS J       Date:  2014-11-15

6.  Total versus partial knee replacement in patients with medial compartment knee osteoarthritis: the TOPKAT RCT.

Authors:  David J Beard; Loretta J Davies; Jonathan A Cook; Graeme MacLennan; Andrew Price; Seamus Kent; Jemma Hudson; Andrew Carr; Jose Leal; Helen Campbell; Ray Fitzpatrick; Nigel Arden; David Murray; Marion K Campbell
Journal:  Health Technol Assess       Date:  2020-04       Impact factor: 4.014

7.  Revision of 33 unicompartmental knee prostheses using total knee arthroplasty: strategy and results.

Authors:  Dominique Saragaglia; Gilles Estour; Charbel Nemer; Pierre-Emmanuel Colle
Journal:  Int Orthop       Date:  2008-06-18       Impact factor: 3.075

8.  Analysis of revision procedures for failed unicondylar knee replacement.

Authors:  K O Oduwole; M K Sayana; F Onayemi; T McCarthy; J O'Byrne
Journal:  Ir J Med Sci       Date:  2009-12-02       Impact factor: 1.568

9.  Outcome of revision of unicompartmental knee replacement.

Authors:  Jacqueline R Hang; Tyman E Stanford; Stephen E Graves; David C Davidson; Richard N de Steiger; Lisa N Miller
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

10.  Results of a French multicentre retrospective experience with four hundred and eighteen failed unicondylar knee arthroplasties.

Authors:  Dominique Saragaglia; Michel Bonnin; David Dejour; Gérard Deschamps; Christophe Chol; Benoit Chabert; Ramsay Refaie
Journal:  Int Orthop       Date:  2013-05-29       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.