Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers.

George H Crossley1, Jane Chen, Wassim Choucair, Todd J Cohen, Douglas C Gohn, W Ben Johnson, Eleanor E Kennedy, Luc R Mongeon, Gerald A Serwer, Hongyan Qiao, Bruce L Wilkoff.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate remote pacemaker interrogation for the earlier diagnosis of clinically actionable events compared with traditional transtelephonic monitoring and routine in-person evaluation.
BACKGROUND: Pacemaker patient follow-up procedures have evolved from evaluating devices with little programmability and diagnostic information solely in person to transtelephonic rhythm strip recordings that allow monitoring of basic device function. More recently developed remote monitoring technology leverages expanded device capabilities, augmenting traditional transtelephonic monitoring to evaluate patients via full device interrogation.
METHODS: The time to first diagnosis of a clinically actionable event was compared in patients who were followed by remote interrogation (Remote) and those who were followed per standard of care with office visits augmented by transtelephonic monitoring (Control). Patients were randomized 2:1. Remote arm patients transmitted pacemaker information at 3-month intervals. Control arm patients with a single-chamber pacemaker transmitted at 2-month intervals. Control arm patients with dual-chamber devices transmitted at 2-month intervals with an office visit at 6 months. All patients were seen in office at 12 months.
RESULTS: The mean time to first diagnosis of clinically actionable events was earlier in the Remote arm (5.7 months) than in the Control arm (7.7 months). Three (2%) of the 190 events in the Control arm and 446 (66%) of 676 events in the Remote arm were identified remotely.
CONCLUSIONS: The strategic use of remote pacemaker interrogation follow-up detects actionable events that are potentially important more quickly and more frequently than transtelephonic rhythm strip recordings. The use of transtelephonic rhythm strips for pacemaker follow-up is of little value except for battery status determinations. (PREFER [Pacemaker Remote Follow-up Evaluation and Review]; NCT00294645).

Entities:  

Mesh:

Year:  2009        PMID: 19926006     DOI: 10.1016/j.jacc.2009.10.001

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  40 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  Increasing knowledge and changing views in cardiac resynchronization therapy.

Authors:  Laszlo Buga; John G F Cleland
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

3.  Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.

Authors:  Paul Chun Yih Lim; Audry Shan Yin Lee; Kelvin Chi Ming Chua; Eric Tien Siang Lim; Daniel Thuan Tee Chong; Boon Yew Tan; Kah Leng Ho; Wee Siong Teo; Chi Keong Ching
Journal:  Singapore Med J       Date:  2016-07       Impact factor: 1.858

4.  Putting down the phone: the obsolescence of transtelephonic monitoring for pacemaker follow-up.

Authors:  Samuel A Shabtaie; Alan Sugrue; Nicholas Y Tan; Samuel Asirvatham; David L Hayes
Journal:  J Interv Card Electrophysiol       Date:  2018-10-23       Impact factor: 1.900

Review 5.  Internet-based device-assisted remote monitoring of cardiovascular implantable electronic devices: an evidence-based analysis.

Authors:  G Pron; L Ieraci; K Kaulback
Journal:  Ont Health Technol Assess Ser       Date:  2012-01-01

Review 6.  Technology-assisted congestive heart failure care.

Authors:  P Iyngkaran; S R Toukhsati; N Biddagardi; H Zimmet; J J Atherton; D L Hare
Journal:  Curr Heart Fail Rep       Date:  2015-04

Review 7.  How to improve outcomes: should we put more emphasis on programming and medical care and less on patient selection?

Authors:  Laszlo Buga
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

8.  Undetected supraventricular tachycardia causing congestive heart failure: a pitfall of remote monitoring system.

Authors:  Keisuke Nakabayashi; Ryo Sugiura; Toshiaki Oka
Journal:  BMJ Case Rep       Date:  2015-07-08

Review 9.  Remote monitoring of cardiac implantable electronic devices (CIED).

Authors:  Emily P Zeitler; Jonathan P Piccini
Journal:  Trends Cardiovasc Med       Date:  2016-03-31       Impact factor: 6.677

10.  Postmarket surveillance of medical devices: current capabilities and future opportunities.

Authors:  Kathleen Blake
Journal:  J Interv Card Electrophysiol       Date:  2013-03-12       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.