A prospective multicenter audit of labor-room episiotomy and anal sphincter injury assessment in the Netherlands.

Jeroen van Dillen1, Maaike Spaans, Wilma van Keijsteren, Marieke van Dillen, Corla Vredevoogd, Marloes van Huizen, Annemieke Middeldorp.   

Abstract

OBJECTIVE: To assess the length and angle of mediolateral episiotomies performed by midwives and resident gynecologists at 3 teaching hospitals in the Netherlands, and determine the incidence of obstetric anal sphincter injury.
METHODS: In this prospective audit conducted between February and September 2008, all women delivered at the 3 hospitals were examined in the labor room for perineal injury. When an injury was assessed as being grade 2 or higher, it was re-evaluated. The incidence of anal sphincter injury was then compared with that reported in the preceding year.
RESULTS: Of 1979 women delivered, 420 (21.2%) were given an episiotomy and 58 (2.9%) sustained anal sphincter injury. The episiotomies formed a mean angle of 40 degrees with the perineal midline. There was no difference in length or angle between the episiotomies performed by resident gynecologists and those performed by midwives, and the angle of most episiotomies was sufficiently wide. Compared with the preceding year, the rate of anal sphincter injury was significantly higher.
CONCLUSION: The quality of episiotomies did not differ when performed by midwives or resident gynecologists. To improve the recognition and classification of obstetric anal sphincter injuries, audits based on an internationally accredited classification could easily become a part of routine hospital practice. Copyright 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19922933     DOI: 10.1016/j.ijgo.2009.08.021

Source DB:  PubMed          Journal:  Int J Gynaecol Obstet        ISSN: 0020-7292            Impact factor:   3.561


  8 in total

1.  Hands on or hands off the perineum: a survey of care of the perineum in labour (HOOPS).

Authors:  Ruben Trochez; Malcolm Waterfield; Robert M Freeman
Journal:  Int Urogynecol J       Date:  2011-05-25       Impact factor: 2.894

Review 2.  The correct episiotomy: does it exist? A cross-sectional survey of four public Israeli hospitals and review of the literature.

Authors:  Lena Sagi-Dain; Shlomi Sagi
Journal:  Int Urogynecol J       Date:  2015-04-02       Impact factor: 2.894

3.  The optimal angle of the mediolateral episiotomy at crowning of the head during labor.

Authors:  Shimon Ginath; Osnat Elyashiv; Eran Weiner; Ron Sagiv; Jacob Bar; Joseph Menczer; Michal Kovo; Alexander Condrea
Journal:  Int Urogynecol J       Date:  2017-05-05       Impact factor: 2.894

4.  Risk factors for obstetric anal sphincter injuries and postpartum anal and urinary incontinence: a case-control trial.

Authors:  Madeline Burrell; Sapna Dilgir; Vicki Patton; Katrina Parkin; Emmanuel Karantanis
Journal:  Int Urogynecol J       Date:  2014-07-31       Impact factor: 2.894

5.  Trigonometric characteristics of episiotomy and risks for obstetric anal sphincter injuries in operative vaginal delivery.

Authors:  E Gonzalez-Díaz; L Moreno Cea; A Fernández Corona
Journal:  Int Urogynecol J       Date:  2014-09-17       Impact factor: 2.894

6.  Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case-control study.

Authors:  M Stedenfeldt; J Pirhonen; E Blix; T Wilsgaard; B Vonen; P Øian
Journal:  BJOG       Date:  2012-03-06       Impact factor: 6.531

7.  The effect of perineal control with hands-on and hand-poised methods on perineal trauma and delivery outcome.

Authors:  Azam Foroughipour; Farah Firuzeh; Ataolah Ghahiri; Vajihe Norbakhsh; Tayebeh Heidari
Journal:  J Res Med Sci       Date:  2011-08       Impact factor: 1.852

8.  Randomized trial comparing episiotomies with Braun-Stadler episiotomy scissors and EPISCISSORS-60(®).

Authors:  Ganpat Sawant; Divya Kumar
Journal:  Med Devices (Auckl)       Date:  2015-06-01