Literature DB >> 19921363

Comparison of Parker-tipped and Murphy-tipped tracheal tubes in Airway Scope-assisted intubation in a manikin.

Takuro Sanuki1, Shingo Sugioka, Motoko Hirokane, Naotaka Kishimoto, Yoshiko Matsuda, Junichiro Kotani.   

Abstract

PURPOSE: We tested our hypothesis that a Parker-tipped tracheal tube could improve the reliability of tracheal tube passage as compared to a Murphy-tipped tracheal tube during Airway Scope-assisted intubation in a manikin.
METHODS: Twenty-seven resident doctors performed Airway Scope-assisted intubations using both tracheal tubes, and the number of times the tracheal tube tip touched the glottis or other laryngeal structures was counted on the Airway Scope monitor.
RESULTS: The incidence of the tracheal tube tip touching the glottis during Airway Scope-assisted intubation using the Parker-tipped tracheal tube (7.4%; 2 of 27 attempts) was significantly less than that obtained using the Murphy-tipped tracheal tube (33.3%; 9 of 27 attempts; P = 0.039).
CONCLUSION: When the advancement of a conventional tracheal tube during Airway Scope-assisted intubation is likely to result in collision with the glottis or other laryngeal structures, the selection of a Parker-tipped tracheal tube is a better option.

Entities:  

Mesh:

Year:  2009        PMID: 19921363     DOI: 10.1007/s00540-009-0812-x

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  11 in total

1.  Parker Flex-Tip tube for fibreoptic nasotracheal intubation in a case of lingual tonsil hypertrophy.

Authors:  José Higueras; Xavier Onrubia; Amparo Sánchez de Merás; Maria Estruch; Manuel Barberá
Journal:  Can J Anaesth       Date:  2005 Aug-Sep       Impact factor: 5.063

2.  Description and first clinical application of AirWay Scope for tracheal intubation.

Authors:  Jun-ichi Koyama; Tatsuro Aoyama; Yoshikazu Kusano; Tatsuya Seguchi; Kyutaro Kawagishi; Tomomi Iwashita; Kazufumi Okamoto; Hiroshi Okudera; Hiroshi Takasuna; Kazuhiro Hongo
Journal:  J Neurosurg Anesthesiol       Date:  2006-10       Impact factor: 3.956

3.  Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by naive operators: a manikin study.

Authors:  T Miki; G Inagawa; T Kikuchi; Y Koyama; T Goto
Journal:  Acta Anaesthesiol Scand       Date:  2007-11       Impact factor: 2.105

4.  The Parker Flex-Tip tracheal tube makes endotracheal intubation with the Bullard laryngoscope easier and faster.

Authors:  A Suzuki; A Tampo; N Abe; S Otomo; S Minami; J J Henderson; H Iwasaki
Journal:  Eur J Anaesthesiol       Date:  2007-08-01       Impact factor: 4.330

5.  Airway Scope: early clinical experience in 405 patients.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

6.  Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.

Authors:  Y Koyama; G Inagawa; T Miyashita; T Kikuchi; N Miura; T Miki; R Kurihara; Y Kamiya; T Goto
Journal:  Anaesthesia       Date:  2007-09       Impact factor: 6.955

7.  Use of a new videolaryngoscope (Airway Scope) in the management of difficult airway.

Authors:  Yoshihiro Hirabayashi; Norimasa Seo
Journal:  J Anesth       Date:  2007-08-01       Impact factor: 2.078

8.  Airway scope and StyletScope for tracheal intubation in a simulated difficult airway.

Authors:  Ryu Komatsu; Kotoe Kamata; Keiko Hamada; Daniel I Sessler; Makoto Ozaki
Journal:  Anesth Analg       Date:  2009-01       Impact factor: 5.108

9.  [Use of a gum elastic bougie for tracheal intubation with Pentax-AWS airway scope].

Authors:  Hironobu Ueshima; Takashi Asai; Koh Shingu; Hisashi Inoue; Yuichi Hashimoto; Yoshiro Enomoto; Yasuhisa Okuda
Journal:  Masui       Date:  2008-01

10.  The Parker Flex-Tip tube versus a standard tube for fiberoptic orotracheal intubation: a randomized double-blind study.

Authors:  Michael S Kristensen
Journal:  Anesthesiology       Date:  2003-02       Impact factor: 7.892

View more
  1 in total

1.  Performance of a Parker Flex-Tip tube(®) for intubation with the Pentax-AirwayScope(®).

Authors:  Xue Hua Chen; Di Wu; Fu Shan Xue
Journal:  J Anesth       Date:  2012-09-19       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.