Literature DB >> 17697222

Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.

Y Koyama1, G Inagawa, T Miyashita, T Kikuchi, N Miura, T Miki, R Kurihara, Y Kamiya, T Goto.   

Abstract

We compared the Airway Scope with a gum elastic bougie and fibreoptic bronchoscope in a manikin with a simulated Cormack and Lehane Grade 3 laryngoscopic view. Twenty-seven anaesthetists intubated the trachea of the manikin with these devices and the time required for intubation was measured. They were then asked to rate the subjective difficulty of intubation (1 = very easy; 5 = very difficult). Mean (SD) intubation times were 16.6 (11.2) s with the Airway Scope, 29.4 (10.9) s with the gum elastic bougie (p < 0.0001), and 30.6 (20.0) s with the fibreoptic bronchoscope (p < 0.0001). The median (range) difficulty was 2 (1-4) with the Airway Scope, 3 (2-4) with the gum elastic bougie (p < 0.001), and 2 (1-5) with the fibreoptic bronchoscope (p = 0.014). In Cormack and Lehane grade 3 laryngoscopic views, the Airway Scope may enable faster and easier tracheal intubation than does a Macintosh laryngoscope with a gum elastic bougie or a fibreoptic bronchoscope.

Entities:  

Mesh:

Year:  2007        PMID: 17697222     DOI: 10.1111/j.1365-2044.2007.05152.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  Comparison of intubation performance between the King Vision and Macintosh laryngoscopes in novice personnel: a randomized, crossover manikin study.

Authors:  Yuki Akihisa; Koichi Maruyama; Yukihide Koyama; Rieko Yamada; Akira Ogura; Tomio Andoh
Journal:  J Anesth       Date:  2013-06-30       Impact factor: 2.078

2.  Comparison of Parker-tipped and Murphy-tipped tracheal tubes in Airway Scope-assisted intubation in a manikin.

Authors:  Takuro Sanuki; Shingo Sugioka; Motoko Hirokane; Naotaka Kishimoto; Yoshiko Matsuda; Junichiro Kotani
Journal:  J Anesth       Date:  2009-11-18       Impact factor: 2.078

3.  Simulation and anaesthesia.

Authors:  Milind Bhagwat
Journal:  Indian J Anaesth       Date:  2012-01

4.  Supraglottic airway device versus a channeled or non-channeled blade-type videolaryngoscope for accidental extubation in the prone position: A randomized crossover manikin study.

Authors:  Hiroyuki Oshika; Yukihide Koyama; Masataka Taguri; Koichi Maruyama; Go Hirabayashi; Shoko Merrit Yamada; Masashi Kohno; Tomio Andoh
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

5.  Comparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation.

Authors:  Sajid Nasim; Chrisen H Maharaj; Muhammad A Malik; John O' Donnell; Brendan D Higgins; John G Laffey
Journal:  BMC Emerg Med       Date:  2009-05-17

6.  Usefulness of video-laryngoscopy with the Airway Scope for intubation performance and learning: an experimental manikin controlled study.

Authors:  Pierre-Louis Declercq; Michael Bubenheim; Stéphanie Gelinotte; Kévin Guernon; Jean-Baptiste Michot; Vincent Royon; Dorothée Carpentier; Gaëtan Béduneau; Fabienne Tamion; Christophe Girault
Journal:  Ann Intensive Care       Date:  2016-08-26       Impact factor: 6.925

7.  Comparison of intubation times using a manikin with an immobilized cervical spine: Macintosh laryngoscope vs. GlideScope vs. fiberoptic bronchoscope.

Authors:  Jung-In Ko; Sang Ook Ha; Min Seok Koo; Miyoung Kwon; Jieun Kim; Jin Jeon; So Hee Park; Sangwoo Shim; Youjin Chang; Taejin Park
Journal:  Clin Exp Emerg Med       Date:  2015-12-28
  7 in total