Literature DB >> 1991772

Immunopathological response to loose cementless acetabular components.

S Santavirta1, Y T Konttinen, V Hoikka, A Eskola.   

Abstract

The membranes surrounding seven loose cementless acetabular implants were shown to contain polyethylene particles, birefringent in polarised light. Three of these implants were made of titanium alloy and the membranes around these contained titanium particles as well. There was no metallosis around the four implants made of chromium-cobalt-steel alloy. Both titanium and polyethylene particles caused migration, adherence and phagocytosis of CD11b-positive, peroxidase-negative macrophages. There were no histological signs of activation of the specific immune response; neither interleukin-2 receptor-positive activated T cells nor PCA-1 plasmablasts/plasma cells were present in the tissues. In cases of simple loosening, resident mesenchymal fibroblast-like cells were active. In aggressive granulomatosis, there were many macrophages and multinucleated giant cells but little fibroblast reaction. The clinical relevance of the findings is that the use of cementless prostheses is not a guarantee against adverse tissue reactions.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1991772

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

1.  Expression of tenascin-C in aseptic loosening of total hip replacement.

Authors:  Y T Konttinen; T F Li; O Michelsson; J W Xu; T Sorsa; S Santavirta; S Imai; I Virtanen
Journal:  Ann Rheum Dis       Date:  1998-10       Impact factor: 19.103

2.  Neovascularisation and the induction of cell adhesion molecules in response to degradation products from orthopaedic implants.

Authors:  N al-Saffar; J T Mah; Y Kadoya; P A Revell
Journal:  Ann Rheum Dis       Date:  1995-03       Impact factor: 19.103

3.  Biocompatibility of hydroxyapatite-coated hip prostheses.

Authors:  S Santavirta; D Nordström; P Ylinen; Y T Konttinen; T Silvennoinen; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

4.  Macrophage-colony stimulating factor (M-CSF) is increased in the synovial-like membrane of the periprosthetic tissues in the aseptic loosening of total hip replacement (THR).

Authors:  J W Xu; Y T Konttinen; V Waris; H Pätiälä; T Sorsa; S Santavirta
Journal:  Clin Rheumatol       Date:  1997-05       Impact factor: 2.980

5.  [Metallurgical differentiation of cobalt-chromium alloys for implants].

Authors:  U Holzwarth; P Thomas; W Kachler; J Göske; A Schuh
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

6.  Local immune inflammatory response to infected total hip and knee replacements.

Authors:  D Nordström; S Santavirta; I Antti-Poika; Y T Konttinen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

7.  [Pathological findings in tissue surrounding revised metal/metal articulations].

Authors:  W Baur; W Hönle; H-G Willert; A Schuh
Journal:  Orthopade       Date:  2005-03       Impact factor: 1.087

8.  Fibroblasts from the inner granulation tissue of the pseudocapsule in hips at revision arthroplasty induce osteoclast differentiation, as do stromal cells.

Authors:  H Sakai; S Jingushi; T Shuto; K Urabe; T Ikenoue; K Okazaki; T Kukita; A Kukita; Y Iwamoto
Journal:  Ann Rheum Dis       Date:  2002-02       Impact factor: 19.103

9.  Serum levels of interleukin 6 (IL-6), granulocyte-macrophage colony-stimulating factor (GM-CSF) and elastase in aseptic prosthetic loosening.

Authors:  Nikolaus A Streich; Steffen J Breusch; Ulrich Schneider
Journal:  Int Orthop       Date:  2003-07-15       Impact factor: 3.075

10.  Proliferative cell response to loosening of total hip replacements: a cytofluorographic cell cycle analysis.

Authors:  S Santavirta; J Pajamäki; A Eskola; Y T Konttinen; T Lindholm
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

View more