Literature DB >> 1991771

Micromotion of cemented and uncemented femoral components.

D W Burke1, D O O'Connor, E B Zalenski, M Jasty, W H Harris.   

Abstract

We evaluated the initial stability of cemented and uncemented femoral components within the femoral canals of cadaver femurs during simulated single limb stance and stair climbing. Both types were very stable in simulated single limb stance (maximum micromotion of 42 microns for cemented and 30 microns for uncemented components). However, in simulated stair climbing, the cemented components were much more stable than the uncemented components (76 microns as against 280 microns). There was also greater variation in the stability of uncemented components in simulated stair climbing, with two of the seven components moving 200 microns or more. Future implant designs should aim to improve the initial stability of cementless femoral components under torsional loads; this should improve the chances of bony ingrowth.

Mesh:

Substances:

Year:  1991        PMID: 1991771

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  15 in total

1.  Bilayered calcium phosphate coating to promote osseointegration of a femoral stem prosthesis.

Authors:  E Goyenvalle; N J M Guyen; E Aguado; N Passuti; G Daculsi
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

2.  Hip painful prosthesis: surgical view.

Authors:  Antonio Spinarelli; Vittorio Patella; Vito Conserva; Giovanni Vicenti; Vito Pesce; Silvio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2011-05

3.  Measuring stability of wire cerclage in femoral fractures when performing total hip replacement. In vitro study on a standardized bone model.

Authors:  M Wagner; F Knorr-Held; D Hohmann
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

4.  High throughput fluorometric technique for assessment of macrophage phagocytosis and actin polymerization.

Authors:  Jana Ninković; Sabita Roy
Journal:  J Vis Exp       Date:  2014-11-27       Impact factor: 1.355

5.  Interface micromotion of uncemented femoral components from postmortem retrieved total hip replacements.

Authors:  Kenneth A Mann; Mark A Miller; Peter A Costa; Amos Race; Timothy H Izant
Journal:  J Arthroplasty       Date:  2011-07-01       Impact factor: 4.757

6.  Revision arthroplasty with an isoelastic uncemented femoral stem.

Authors:  T J Niinimäki; J P Puranen; P K Jalovaara
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

7.  Uncemented total hip replacements and thigh pain.

Authors:  G Petrou; M Gavras; A Diamantopoulos; T Kapetsis; N Kremmydas; A Kouzoupis
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

8.  The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem.

Authors:  Youngbae Park; Carolyne Albert; Yong-San Yoon; Göran Fernlund; Hanspeter Frei; Thomas R Oxland
Journal:  J Orthop Surg Res       Date:  2010-06-24       Impact factor: 2.359

9.  [Total hip arthroplasty in Austria. Results of a nationwide survey based on a questionnaire].

Authors:  W Brodner; B Raffelsberger
Journal:  Orthopade       Date:  2004-04       Impact factor: 1.087

10.  Assessment of the primary rotational stability of uncemented hip stems using an analytical model: comparison with finite element analyses.

Authors:  Maria E Zeman; Nicolas Sauwen; Luc Labey; Michiel Mulier; Georges Van der Perre; Siegfried V N Jaecques
Journal:  J Orthop Surg Res       Date:  2008-09-25       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.