Literature DB >> 19912269

In vivo and in vitro biofilm formation on two different titanium implant surfaces.

Ralf Bürgers1, Till Gerlach, Sebastian Hahnel, Frank Schwarz, Gerhard Handel, Martin Gosau.   

Abstract

OBJECTIVES: The aim of the present in vitro and human in vivo study was twofold: first, to evaluate the initial biofilm formation on different titanium implant surfaces by means of two highly sensitive fluorescent techniques and, second, to correlate these findings to different surface properties.
MATERIALS AND METHODS: In vivo biofilm formation was induced on purely machined (Pt) and on sand-blasted and acid-etched titanium (Prom) specimens, which were mounted buccally on individual splints and worn by six study participants for 12 h. In vitro bacterial adhesion was also investigated after incubation with Streptococcus sanguinis suspension (37 degrees C, 2 h). Adherent bacteria were quantified by the following fluorescence techniques: Resazurin staining in combination with an automated fluorescence reader or live/dead cell labeling and fluorescence microscopy. Surface roughness (R(a)) was determined with a perthometer, and surface free energy (SFE) was measured with a goniometer.
RESULTS: Prom showed a significantly higher median R(a) (0.95 microm) and a significantly lower median SFE (18.3 mJ/m(2)) than Pt (R(a)=0.15 microm; SFE=39.6 mJ/m(2)). The in vitro and in vivo tests showed a significantly higher bacterial adhesion to Prom than to Pt, and the initial biofilm formation on Pt corresponded to the circular surface modifications on the machined substratum. Both observations may be attributed to the predominant influence of surface roughness on bacterial adhesion. No significant differences in the percentage of dead cells among all adhering bacteria were found between Prom (23.7%) and Pt (29.1%). Ectopic solitary epithelial cells from the oral mucosa - strongly adhering to the substratum - were found on each Prom specimen, but not on any of the Pt surfaces.
CONCLUSIONS: Initial bacterial adhesion to differently textured titanium surfaces is primarily influenced by R(a), whereas the influence of SFE seems to be of only minor importance. Therefore, the micro-structured parts of an implant that are exposed to the oral cavity should be highly polished to prevent plaque accumulation. Both tested fluorometric techniques proved to be highly sensitive and reproducible in the quantification of biofilm formation on titanium implant surfaces.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19912269     DOI: 10.1111/j.1600-0501.2009.01815.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  46 in total

1.  In vitro evaluation of a multispecies oral biofilm over antibacterial coated titanium surfaces.

Authors:  Javi Vilarrasa; Luis M Delgado; Marta Galofré; Gerard Àlvarez; Deborah Violant; José María Manero; Vanessa Blanc; F Javier Gil; José Nart
Journal:  J Mater Sci Mater Med       Date:  2018-11-03       Impact factor: 3.896

2.  Efficacy of various side-to-side toothbrushes for noncontact biofilm removal.

Authors:  Julia C Schmidt; Monika Astasov-Frauenhoffer; Irmgard Hauser-Gerspach; Jan-Philipp Schmidt; Tuomas Waltimo; Roland Weiger; Clemens Walter
Journal:  Clin Oral Investig       Date:  2013-07-20       Impact factor: 3.573

3.  Oral Biofilm Formation on Different Materials for Dental Implants.

Authors:  Thalisson S O Silva; Alice R Freitas; Marília L L Pinheiro; Cássio do Nascimento; Evandro Watanabe; Rubens F Albuquerque
Journal:  J Vis Exp       Date:  2018-06-24       Impact factor: 1.355

4.  Efficacy of a new coating of implant-abutment connections in reducing bacterial loading: an in vitro study.

Authors:  D Lauritano; C A Bignozzi; D Pazzi; F Cura; F Carinci
Journal:  Oral Implantol (Rome)       Date:  2017-04-10

5.  Plaque accumulation on titanium disks with different surface treatments: an in vivo investigation.

Authors:  Enrico Conserva; Luigi Generali; Alberto Bandieri; Francesco Cavani; Francesco Borghi; Ugo Consolo
Journal:  Odontology       Date:  2017-08-22       Impact factor: 2.634

6.  Streptococcus sanguinis adhesion on titanium rough surfaces: effect of shot-blasting particles.

Authors:  Ana G Rodríguez-Hernández; A Juárez; E Engel; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2011-06-09       Impact factor: 3.896

7.  Biofilm rupture by laser-induced stress waves increases with loading amplitude, independent of location.

Authors:  Kaitlyn L Kearns; James D Boyd; Martha E Grady
Journal:  ACS Appl Bio Mater       Date:  2020-02-12

8.  Metagenomic analysis of the peri-implant and periodontal microflora in patients with clinical signs of gingivitis or mucositis.

Authors:  Wieland Heuer; Andreas Kettenring; Sascha Nico Stumpp; Jörg Eberhard; Eva Gellermann; Andreas Winkel; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2011-05-03       Impact factor: 3.573

9.  Bacteria and osteoblast adhesion to chitosan immobilized titanium surface: A race for the surface.

Authors:  Berit L Foss; Niranjan Ghimire; Ruogu Tang; Yuyu Sun; Ying Deng
Journal:  Colloids Surf B Biointerfaces       Date:  2015-07-17       Impact factor: 5.268

10.  Biofilms Developed on Dental Implant Titanium Surfaces with Different Roughness: Comparison Between In Vitro and In Vivo Studies.

Authors:  Lorenzo Bevilacqua; Annalisa Milan; Veronica Del Lupo; Michele Maglione; Lucilla Dolzani
Journal:  Curr Microbiol       Date:  2018-02-27       Impact factor: 2.188

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.