Vimal K Narula1, Dean J Mikami, W Scott Melvin. 1. Division of General and Gastrointestinal Surgery, Department of Surgery, Center for Minimally Invasive Surgery, The Ohio State University Medical Center, Columbus, OH 43210-1228, USA. raaja.narula@osumc.edu
Abstract
OBJECTIVES: Minimally invasive surgery is beneficial for complex operations; robotics may improve performance in these procedures; however, robotic pancreaticoduodenectomy (PD) has been plagued by long operative times. We describe a small series (n = 5) of patients who underwent a hybrid PD for treatment of obstructive jaundice and pancreatic mass. METHODS: After diagnostic laparoscopy, the gallbladder was retracted cephalad and the porta hepatis was dissected. The lesser sac was opened to expose the superior mesenteric vein below the pancreas. Once the vein was cleared, the bile duct, stomach, pancreas, and jejunum were transected. After the uncinate process was cleared, the specimen was removed. The da Vinci S Surgical Robotic System was docked to perform a mucosa-to-mucosa pancreaticojejunostomy and an end-to-side choledochojejunostomy. A stapled gastrojejunostomy and drain placement completed the operation. RESULTS: Five patients underwent hybrid PD between May 2006 and June 2007. All patients had a history of pancreatitis and presented with obstructive jaundice and a pancreatic mass. The operations were completed with 5 ports. The mean operative time was 7 hours. The mean hospital stay was 9.6 days. At 6 months after the operation, all patients were disease-free. CONCLUSIONS: Complex procedures such as PD can be accomplished with minimally invasive surgical techniques using robotic instrumentation.
OBJECTIVES: Minimally invasive surgery is beneficial for complex operations; robotics may improve performance in these procedures; however, robotic pancreaticoduodenectomy (PD) has been plagued by long operative times. We describe a small series (n = 5) of patients who underwent a hybrid PD for treatment of obstructive jaundice and pancreatic mass. METHODS: After diagnostic laparoscopy, the gallbladder was retracted cephalad and the porta hepatis was dissected. The lesser sac was opened to expose the superior mesenteric vein below the pancreas. Once the vein was cleared, the bile duct, stomach, pancreas, and jejunum were transected. After the uncinate process was cleared, the specimen was removed. The da Vinci S Surgical Robotic System was docked to perform a mucosa-to-mucosa pancreaticojejunostomy and an end-to-side choledochojejunostomy. A stapled gastrojejunostomy and drain placement completed the operation. RESULTS: Five patients underwent hybrid PD between May 2006 and June 2007. All patients had a history of pancreatitis and presented with obstructive jaundice and a pancreatic mass. The operations were completed with 5 ports. The mean operative time was 7 hours. The mean hospital stay was 9.6 days. At 6 months after the operation, all patients were disease-free. CONCLUSIONS: Complex procedures such as PD can be accomplished with minimally invasive surgical techniques using robotic instrumentation.
Authors: Erin H Baker; Samuel W Ross; Ramanathan Seshadri; Ryan Z Swan; David A Iannitti; Dionisios Vrochides; John B Martinie Journal: J Gastrointest Oncol Date: 2015-08
Authors: Antonio Luiz de Vasconcellos Macedo; Vladimir Schraibman; Samuel Okazaki; Fernando Concilio Mauro; Marina Gabrielle Epstein; Suzan Menasce Goldman; Suzana A S Lustosa; Delcio Matos Journal: J Robot Surg Date: 2011-01-07
Authors: Josh Winer; Mehmet F Can; David L Bartlett; Herbert J Zeh; Amer H Zureikat Journal: Nat Rev Gastroenterol Hepatol Date: 2012-06-26 Impact factor: 46.802