Literature DB >> 19904402

Rapid automated cell quantification on HIV microfluidic devices.

Mohamad A Alyassin1, SangJun Moon, Hasan O Keles, Fahim Manzur, Richard L Lin, Edward Hæggstrom, Daniel R Kuritzkes, Utkan Demirci.   

Abstract

Lab-chip device analysis often requires high throughput quantification of fluorescent cell images, obtained under different conditions of fluorescent intensity, illumination, focal depth, and optical magnification. Many laboratories still use manual counting--a tedious, expensive process prone to inter-observer variability. The manual counting process can be automated for fast and precise data gathering and reduced manual bias. We present a method to segment and count cells in microfluidic chips that are labeled with a single stain, or multiple stains, using image analysis techniques in Matlab and discuss its advantages over manual counting. Microfluidic based cell capturing devices for HIV monitoring were used to validate our method. Captured CD4(+) CD3(+) T lymphocytes were stained with DAPI, AF488-anti CD4, and AF647-anti CD3 for cell identification. Altogether 4788 (76 x 3 x 21) gray color images were obtained from devices using discarded 10 HIV infected patient whole blood samples (21 devices). We observed that the automatic method performs similarly to manual counting for a small number of cells. However, automated counting is more accurate and more than 100 times faster than manual counting for multiple-color stained cells, especially when large numbers of cells need to be quantified (>500 cells). The algorithm is fully automatic for subsequent microscope images that cover the full device area. It accounts for problems that generally occur in fluorescent lab-chip cell images such as: uneven background, overlapping cell images and cell detection with multiple stains. This method can be used in laboratories to save time and effort, and to increase cell counting accuracy of lab-chip devices for various applications, such as circulating tumor cell detection, cell detection in biosensors, and HIV monitoring devices, i.e. CD4 counts.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19904402      PMCID: PMC3839566          DOI: 10.1039/b911882a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  14 in total

1.  FISH and chips: automation of fluorescent dot counting in interphase cell nuclei.

Authors:  H Netten; I T Young; L J van Vliet; H J Tanke; H Vroljik; W C Sloos
Journal:  Cytometry       Date:  1997-05-01

2.  Rapid and simple quantification of bacterial cells by using a microfluidic device.

Authors:  Chieko Sakamoto; Nobuyasu Yamaguchi; Masao Nasu
Journal:  Appl Environ Microbiol       Date:  2005-02       Impact factor: 4.792

3.  Ultra wide-field lens-free monitoring of cells on-chip.

Authors:  Aydogan Ozcan; Utkan Demirci
Journal:  Lab Chip       Date:  2007-11-01       Impact factor: 6.799

4.  Real-time fluorescence detection of multiple microscale cell culture analog devices in situ.

Authors:  Taek-Il Oh; Jong Hwan Sung; Daniel A Tatosian; Michael L Shuler; Donghyun Kim
Journal:  Cytometry A       Date:  2007-10       Impact factor: 4.355

5.  A microchip approach for practical label-free CD4+ T-cell counting of HIV-infected subjects in resource-poor settings.

Authors:  Xuanhong Cheng; Daniel Irimia; Meredith Dixon; Joshua C Ziperstein; Utkan Demirci; Lee Zamir; Ronald G Tompkins; Mehmet Toner; William R Rodriguez
Journal:  J Acquir Immune Defic Syndr       Date:  2007-07-01       Impact factor: 3.731

6.  CD4+ T-lymphocyte capture using a disposable microfluidic chip for HIV.

Authors:  Sang Jun Moon; Richard Lin; Utkan Demirci
Journal:  J Vis Exp       Date:  2007-10-01       Impact factor: 1.355

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Isolation of rare circulating tumour cells in cancer patients by microchip technology.

Authors:  Sunitha Nagrath; Lecia V Sequist; Shyamala Maheswaran; Daphne W Bell; Daniel Irimia; Lindsey Ulkus; Matthew R Smith; Eunice L Kwak; Subba Digumarthy; Alona Muzikansky; Paula Ryan; Ulysses J Balis; Ronald G Tompkins; Daniel A Haber; Mehmet Toner
Journal:  Nature       Date:  2007-12-20       Impact factor: 49.962

9.  Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need.

Authors:  Jesse V Jokerst; Pierre N Floriano; Nicolaos Christodoulides; Glennon W Simmons; John T McDevitt
Journal:  Lab Chip       Date:  2008-11-05       Impact factor: 6.799

10.  A microchip CD4 counting method for HIV monitoring in resource-poor settings.

Authors:  William R Rodriguez; Nicolaos Christodoulides; Pierre N Floriano; Susan Graham; Sanghamitra Mohanty; Meredith Dixon; Mina Hsiang; Trevor Peter; Shabnam Zavahir; Ibou Thior; Dwight Romanovicz; Bruce Bernard; Adrian P Goodey; Bruce D Walker; John T McDevitt
Journal:  PLoS Med       Date:  2005-07-19       Impact factor: 11.069

View more
  32 in total

1.  Direct numerical simulation of single leukocyte deformation in microchannel flow for disease diagnosis.

Authors:  Z Y Luo; F Xu; T J Lu; B F Bai
Journal:  J Med Syst       Date:  2010-05-05       Impact factor: 4.460

2.  Controlled viable release of selectively captured label-free cells in microchannels.

Authors:  Umut Atakan Gurkan; Tarini Anand; Huseyin Tas; David Elkan; Altug Akay; Hasan Onur Keles; Utkan Demirci
Journal:  Lab Chip       Date:  2011-10-14       Impact factor: 6.799

3.  pH controlled staining of CD4(+) and CD19(+) cells within functionalized microfluidic channel.

Authors:  Mariangela Mortato; Laura Blasi; Giovanna Barbarella; Simona Argentiere; Giuseppe Gigli
Journal:  Biomicrofluidics       Date:  2012-11-05       Impact factor: 2.800

4.  Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care.

Authors:  Shuqi Wang; Xiaohu Zhao; Imran Khimji; Ragip Akbas; Weiliang Qiu; Dale Edwards; Daniel W Cramer; Bin Ye; Utkan Demirci
Journal:  Lab Chip       Date:  2011-09-01       Impact factor: 6.799

5.  Automated and adaptable quantification of cellular alignment from microscopic images for tissue engineering applications.

Authors:  Feng Xu; Turker Beyazoglu; Evan Hefner; Umut Atakan Gurkan; Utkan Demirci
Journal:  Tissue Eng Part C Methods       Date:  2011-04-18       Impact factor: 3.056

6.  Lensless imaging for simultaneous microfluidic sperm monitoring and sorting.

Authors:  Xiaohui Zhang; Imran Khimji; Umut Atakan Gurkan; Hooman Safaee; Paolo Nicolas Catalano; Hasan Onur Keles; Emre Kayaalp; Utkan Demirci
Journal:  Lab Chip       Date:  2011-06-16       Impact factor: 6.799

7.  High-efficiency rare cell identification on a high-density self-assembled cell arrangement chip.

Authors:  Tsung-Ju Chen; Jen-Kuei Wu; Yu-Cheng Chang; Chien-Yu Fu; Tsung-Pao Wang; Chun-Yen Lin; Hwan-You Chang; Ching-Chang Chieng; Chung-Yuh Tzeng; Fan-Gang Tseng
Journal:  Biomicrofluidics       Date:  2014-05-12       Impact factor: 2.800

Review 8.  Point of care testing for infectious diseases.

Authors:  Hui Chen; Kengku Liu; Zhao Li; Ping Wang
Journal:  Clin Chim Acta       Date:  2019-03-08       Impact factor: 3.786

Review 9.  Point-of-care assays for tuberculosis: role of nanotechnology/microfluidics.

Authors:  ShuQi Wang; Fatih Inci; Gennaro De Libero; Amit Singhal; Utkan Demirci
Journal:  Biotechnol Adv       Date:  2013-01-26       Impact factor: 14.227

10.  Nanoplasmonic quantitative detection of intact viruses from unprocessed whole blood.

Authors:  Fatih Inci; Onur Tokel; Shuqi Wang; Umut Atakan Gurkan; Savas Tasoglu; Daniel R Kuritzkes; Utkan Demirci
Journal:  ACS Nano       Date:  2013-05-20       Impact factor: 15.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.