Literature DB >> 19901594

Effective dose variation in pediatric computed tomography: dose reference levels in Greece.

E Yakoumakis1, M Karlatira, G Gialousis, A Dimitriadis, T Makri, E Georgiou.   

Abstract

Computed tomography provides high-resolution imaging of the human body. However, it contributes mainly to the doses on the population. Additionally, the fact that children are two to three times more sensitive to the x rays compared to the adults results in the increased need of taking action for the reduction of the dose regarding the computed tomography examinations. The first part of this paper presents the results of an investigation on the variation of doses to children while the second part compares those results with the European standards. This project took place in twelve hospitals distributed throughout the country. The weighted computed dose-index and the dose length product were calculated for four different age-categories (namely 0, 1, 5 and 10-year-old) and for the three most often examinations (brain, thorax and abdomen). Effective dose values were estimated using coefficients and patients' data. The measurements showed that only a few hospitals are taking into account the protocols regarding the age of the children. As a result, many patients receive high doses without this being necessary. Thus, reducing dose methods should be adapted in order to improve the optimization of this high dose modality.

Entities:  

Mesh:

Year:  2009        PMID: 19901594     DOI: 10.1097/01.HP.0000363840.78169.1b

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  6 in total

Review 1.  CT utilization--trends and developments beyond the United States' borders.

Authors:  Karen E Thomas
Journal:  Pediatr Radiol       Date:  2011-08-17

2.  Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey.

Authors:  Claudio Granata; Daniela Origgi; Federica Palorini; Domenica Matranga; Sergio Salerno
Journal:  Pediatr Radiol       Date:  2014-11-08

3.  National diagnostic reference level initiative for computed tomography examinations in Kenya.

Authors:  Geoffrey K Korir; Jeska S Wambani; Ian K Korir; Mark A Tries; Patrick K Boen
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

4.  Assessment of paediatric CT dose indicators for the purpose of optimisation.

Authors:  Z Brady; F Ramanauskas; T M Cain; P N Johnston
Journal:  Br J Radiol       Date:  2012-07-27       Impact factor: 3.039

5.  Pediatric minor head injury imaging practices: results from an ESPR survey.

Authors:  Maria I Argyropoulou; George A Alexiou; Vassileios G Xydis; Catherine Adamsbaum; Jean-Francois Chateil; Andrea Rossi; Nadine Girard; Élida Vázquez; Loukas G Astrakas
Journal:  Neuroradiology       Date:  2019-12-11       Impact factor: 2.804

6.  Local diagnostic reference levels in pediatric CT examinations: a survey at the largest children's hospital in Greece.

Authors:  Agapi Ploussi; Vasileios Syrgiamiotis; Triantafillia Makri; Christiana Hatzigiorgi; Efstathios P Efstathopoulos
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.