A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: comparison of three drug-eluting stents.

Peter Mortier1, Gerhard A Holzapfel, Matthieu De Beule, Denis Van Loo, Yves Taeymans, Patrick Segers, Pascal Verdonck, Benedict Verhegghe.   

Abstract

The introduction of drug-eluting stents (DES) has reduced the occurrence of restenosis in coronary arteries. However, restenosis remains a problem in stented coronary bifurcations. This study investigates and compares three different second generation DESs when being implanted in the curved main branch of a coronary bifurcation with the aim of providing better insights into the related changes of the mechanical environment. The 3D bifurcation model is based on patient-specific angiographic data that accurately reproduce the in vivo curvatures of the vessel segments. The layered structure of the arterial wall and its anisotropic mechanical behavior are taken into account by applying a novel algorithm to define the fiber orientations. An innovative simulation strategy considering the insertion of a folded balloon catheter over a guide wire is proposed in order to position the stents within the curved vessel. Straightening occurs after implantation of all stents investigated. The resulting distributions of the wall stresses are strongly dependent on the stent design. Using a parametric modeling approach, two design modifications, which reduce the predicted maximum values of the wall stress, are proposed and analyzed.

Entities:  

Mesh:

Year:  2009        PMID: 19898936     DOI: 10.1007/s10439-009-9836-5

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  20 in total

1.  The consequences of the mechanical environment of peripheral arteries for nitinol stenting.

Authors:  Michael Early; Daniel J Kelly
Journal:  Med Biol Eng Comput       Date:  2011-08-11       Impact factor: 2.602

Review 2.  Contemporary Role of Computational Analysis in Endovascular Treatment for Thoracic Aortic Disease.

Authors:  Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi
Journal:  Aorta (Stamford)       Date:  2013-08-01

3.  New strategies in the treatment of coronary bifurcations.

Authors:  I Iakovou; N Foin; A Andreou; N Viceconte; C Di Mario
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

4.  Large-scale subject-specific cerebral arterial tree modeling using automated parametric mesh generation for blood flow simulation.

Authors:  Mahsa Ghaffari; Kevin Tangen; Ali Alaraj; Xinjian Du; Fady T Charbel; Andreas A Linninger
Journal:  Comput Biol Med       Date:  2017-10-24       Impact factor: 4.589

Review 5.  Microstructure-based biomechanics of coronary arteries in health and disease.

Authors:  Huan Chen; Ghassan S Kassab
Journal:  J Biomech       Date:  2016-03-20       Impact factor: 2.712

6.  Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.

Authors:  Shun Nakamura; Shigeki Kimura; Shun Nakagama; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Keiichi Hishikari; Hiroyuki Hikita; Atsushi Takahashi; Kenzo Hirao
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-29       Impact factor: 2.357

7.  Numerical Simulation of Stent Angioplasty with Predilation: An Investigation into Lesion Constitutive Representation and Calcification Influence.

Authors:  C Conway; J P McGarry; E R Edelman; P E McHugh
Journal:  Ann Biomed Eng       Date:  2017-05-09       Impact factor: 3.934

8.  Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics.

Authors:  Annarita Bernardini; Ignacio Larrabide; Hernán G Morales; Giancarlo Pennati; Lorenza Petrini; Salvatore Cito; Alejandro F Frangi
Journal:  Interface Focus       Date:  2011-03-23       Impact factor: 3.906

9.  In silico assessment of the effects of material on stent deployment.

Authors:  Georgia S Karanasiou; Nikolaos S Tachos; Antonios Sakellarios; Lampros K Michalis; Claire Conway; Elazer R Edelman; Dimitrios I Fotiadis
Journal:  Proc IEEE Int Symp Bioinformatics Bioeng       Date:  2018-01-11

Review 10.  A literature review of the numerical analysis of abdominal aortic aneurysms treated with endovascular stent grafts.

Authors:  David Roy; Claude Kauffmann; Sébastien Delorme; Sophie Lerouge; Guy Cloutier; Gilles Soulez
Journal:  Comput Math Methods Med       Date:  2012-09-06       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.