Literature DB >> 19894173

On wiping the interior walls of 37-mm closed-face cassettes: an OSHA perspective.

Warren Hendricks1, Fern Stones, Dean Lillquist.   

Abstract

As early as 1976, Occupational Safety and Health Administration (OSHA) methods for analyzing metal samples collected using 37-mm polystyrene closed-face cassettes specified that any loose dust be transferred from the cassette to the digestion vessel, that the cassette be rinsed, and that, if necessary, the cassette be wiped out to help ensure that all particles that enter the cassette are included along with the filter as part of the sample for analysis. OSHA analytical methods for metal analysis were recently revised to explicitly require cassette wiping for all metal samples. This change was based on policy that any material entering the collection device constitutes part of the sample and on OSHA Salt Lake Technical Center research showing that invisible residue on the cassette walls can significantly contribute to the total sample results reported. OSHA procedures are consistent with guidance given in the NIOSH Manual of Analytical Methods. This guidance concludes that internal deposits in sampling cassettes should be included in the analysis and that one way to accomplish this would be to wipe or wash the internal surfaces of the cassette and include the material along with the filter for analysis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19894173     DOI: 10.1080/15459620903012028

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  8 in total

1.  Solid versus liquid particle sampling efficiency of three personal aerosol samplers when facing the wind.

Authors:  Kirsten A Koehler; T Renee Anthony; Michael Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2011-09-29

2.  Preliminary studies on the use of acid-soluble cellulose acetate internal capsules for workplace metals sampling and analysis.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2012       Impact factor: 2.155

3.  Comparison of lead and tin concentrations in air at a solder manufacturer from the closed-face 37-mm cassette with and without a custom cellulose-acetate cassette insert.

Authors:  Eun Gyung Lee; William P Chisholm; Dru A Burns; John H Nelson; Michael L Kashon; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

4.  Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.

Authors:  Kevin Ashley; Martin Harper
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

5.  Comparison of a Wipe Method With and Without a Rinse to Recover Wall Losses in Closed Face 37-mm Cassettes used for Sampling Lead Dust Particulates.

Authors:  Diana Ceballos; Bradley King; Catherine Beaucham; Scott E Brueck
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

6.  Criteria for the collection of useful respirator performance data in the workplace.

Authors:  Larry Janssen; Ziqing Zhuang; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

7.  Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

Review 8.  Recent Advances in Occupational Exposure Assessment of Aerosols.

Authors:  Martin Harper
Journal:  Int J Environ Res Public Health       Date:  2020-09-18       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.