Literature DB >> 19892569

Axial CID and high pressure resonance CID in a miniature ion trap mass spectrometer using a discontinuous atmospheric pressure interface.

Liang Gao1, Guangtao Li, R Graham Cooks.   

Abstract

Axial collision induced dissociation (CID) and high-pressure resonance CID were implemented and compared with normal low-pressure resonance CID in a miniature ion trap mass spectrometer to obtain more complete fragmentation spectra. Axial CID was realized simply by applying a potential to the discontinuous atmospheric pressure interface (DAPI) capillary without performing parent ion isolation before dissociation. High-pressure resonance CID employed a double-introduction pulse scan function, by means of which precursor ions isolated at low-pressure (<10(-3) torr) were dissociated at high-pressure (0.1 torr-1 torr) with higher excitation energy, so that tandem MS of isolated precursor ions was achieved and extensive fragmentation was obtained. A simple peptide (Leu-enkephalin) and dye molecule (rhodamine B) ionized by ESI were used to investigate both methods and compare them with normal low-pressure resonance CID. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2009        PMID: 19892569     DOI: 10.1016/j.jasms.2009.10.005

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.

Authors:  Zheng Ouyang; Guangxiang Wu; Yishu Song; Hongyan Li; Wolfgang R Plass; R Graham Cooks
Journal:  Anal Chem       Date:  2004-08-15       Impact factor: 6.986

Review 2.  Triple quadrupole linear ion trap mass spectrometer for the analysis of small molecules and macromolecules.

Authors:  Gérard Hopfgartner; Emmanuel Varesio; Viviane Tschäppät; Chantal Grivet; Emmanuel Bourgogne; Luc Alexis Leuthold
Journal:  J Mass Spectrom       Date:  2004-08       Impact factor: 1.982

3.  Establishing low-energy sequential decomposition pathways of leucine enkephalin and its N- and C-terminus fragments using multiple-resonance CID in quadrupolar ion guide.

Authors:  V Sergey Rakov; Oleg V Borisov; Craig M Whitehouse
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

4.  Handheld rectilinear ion trap mass spectrometer.

Authors:  Liang Gao; Qingyu Song; Garth E Patterson; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2006-09-01       Impact factor: 6.986

5.  Fragmentation of ions in a low pressure linear ion trap.

Authors:  Bruce A Collings
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-10       Impact factor: 3.109

6.  Hand-portable gas chromatograph-toroidal ion trap mass spectrometer (GC-TMS) for detection of hazardous compounds.

Authors:  Jesse A Contreras; Jacolin A Murray; Samuel E Tolley; Joseph L Oliphant; H Dennis Tolley; Stephen A Lammert; Edgar D Lee; Douglas W Later; Milton L Lee
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-03       Impact factor: 3.109

7.  Competition between resonance ejection and ion dissociation during resonant excitation in a quadrupole ion trap.

Authors:  M J Charles; S A McLuckey; G L Glish
Journal:  J Am Soc Mass Spectrom       Date:  1994-12       Impact factor: 3.109

8.  MS/MS of ions in a low pressure linear ion trap using a pulsed gas.

Authors:  Bruce A Collings; Matthew A Romaschin
Journal:  J Am Soc Mass Spectrom       Date:  2009-05-20       Impact factor: 3.109

9.  Design and characterization of a multisource hand-held tandem mass spectrometer.

Authors:  Liang Gao; Andy Sugiarto; Jason D Harper; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-08-29       Impact factor: 6.986

10.  Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface.

Authors:  Liang Gao; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-05-08       Impact factor: 6.986

View more
  4 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Potential distribution and transmission characteristics in a curved quadrupole ion guide.

Authors:  Xiaoyu Zhou; Caiqiao Xiong; Gaoping Xu; Hao Liu; Yin Tang; Zhiqiang Zhu; Rui Chen; Haoxue Qiao; Yao-Hsin Tseng; Wen-Ping Peng; Zongxiu Nie; Yi Chen
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-19       Impact factor: 3.109

Review 3.  Mass spectrometry of natural products: current, emerging and future technologies.

Authors:  Amina Bouslimani; Laura M Sanchez; Neha Garg; Pieter C Dorrestein
Journal:  Nat Prod Rep       Date:  2014-05-07       Impact factor: 13.423

4.  Differential mobility spectrometry with nanospray ion source as a compact detector for small organics and inorganics.

Authors:  Stephen L Coy; Evgeny V Krylov; Erkinjon G Nazarov; Albert J Fornace; Richard D Kidd
Journal:  Int J Ion Mobil Spectrom       Date:  2013-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.