Literature DB >> 18461971

Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface.

Liang Gao1, R Graham Cooks, Zheng Ouyang.   

Abstract

The performance of mass spectrometers with limited pumping capacity is shown to be improved through use of a discontinuous atmospheric pressure interface (DAPI). A proof-of-concept DAPI interface was designed and characterized using a miniature rectilinear ion trap mass spectrometer. The interface consists of a simple capillary directly connecting the atmospheric pressure ion source to the vacuum mass analyzer region; it has no ion optical elements and no differential pumping stages. Gases carrying ionized analytes were pulsed into the mass analyzer for short periods at high flow rates rather than being continuously introduced at lower flow rates; this procedure maximized ion transfer. The use of DAPI provides a simple solution to the problem of coupling an atmospheric pressure ionization source to a miniature instrument with limited pumping capacity. Data were recorded using various atmospheric pressure ionization sources, including electrospray ionization (ESI), nano-ESI, atmospheric pressure chemical ionization (APCI), and desorption electrospray ionization (DESI) sources. The interface was opened briefly for ion introduction during each scan. With the use of the 18 W pumping system of the Mini 10, limits of detection in the low part-per-billion levels were achieved and unit resolution mass spectra were recorded.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18461971     DOI: 10.1021/ac800014v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  41 in total

1.  Silica coated paper substrate for paper-spray analysis of therapeutic drugs in dried blood spots.

Authors:  Zhiping Zhang; Wei Xu; Nicholas E Manicke; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2011-12-23       Impact factor: 6.986

2.  Miniaturization of Mass Spectrometry Analysis Systems.

Authors:  Wei Xu; Nicholas E Manicke; Graham R Cooks; Zheng Ouyang
Journal:  JALA Charlottesv Va       Date:  2010-12

3.  Evaluation of a differential mobility spectrometer/miniature mass spectrometer system.

Authors:  Fatkhulla K Tadjimukhamedov; Ayanna U Jackson; Erkinjon G Nazarov; Zheng Ouyang; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2010-06-09       Impact factor: 3.109

Review 4.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

5.  Probe Heating Method for the Analysis of Solid Samples Using a Portable Mass Spectrometer.

Authors:  Shun Kumano; Masuyuki Sugiyama; Masuyoshi Yamada; Kazushige Nishimura; Hideki Hasegawa; Hidetoshi Morokuma; Hiroyuki Inoue; Yuichiro Hashimoto
Journal:  Mass Spectrom (Tokyo)       Date:  2015-04-25

6.  Super-Atmospheric Pressure Ion Sources: Application and Coupling to API Mass Spectrometer.

Authors:  Lee Chuin Chen; Md Matiur Rahman; Kenzo Hiraoka
Journal:  Mass Spectrom (Tokyo)       Date:  2014-05-01

7.  A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources.

Authors:  Qinghao Wu; Yuan Tian; Ailin Li; Derek Andrews; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-31       Impact factor: 3.109

8.  Simulation of rarefied gas flows in atmospheric pressure interfaces for mass spectrometry systems.

Authors:  Sandilya Garimella; Xiaoyu Zhou; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2013-09-17       Impact factor: 3.109

9.  Ion trap mass analysis at high pressure: a theoretical view.

Authors:  Wei Xu; Qingyu Song; Scott A Smith; William J Chappell; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-10       Impact factor: 3.109

10.  High efficiency tandem mass spectrometry analysis using dual linear ion traps.

Authors:  Linfan Li; Xiaoyu Zhou; James W Hager; Zheng Ouyang
Journal:  Analyst       Date:  2014-10-07       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.