Literature DB >> 19890473

Modern Directions for Potentiometric Sensors.

Eric Bakker1, Karin Chumbimuni-Torres.   

Abstract

This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection limits of ISEs are described, including recent approaches of developing all solid state ISEs, and breakthroughs in detecting ultra-small quantities of ions at low concentrations. These developments have paved the way to use potentiometric sensors as in ultra-sensitive affinity bioanalysis in conjunction with nanoparticle labels. Recent results establish that potentiometry compares favorably to electrochemical stripping analysis. Other new developments with ion-selective electrodes are also described, including the concept of backside calibration potentiometry, controlled current coulometry, pulsed chronopotentiometry, and localized flash titration with ion-selective membranes to design sensors for the direct detection of total acidity without net sample perturbation. These developments have further opened the field for exciting new possibilities and applications.

Year:  2008        PMID: 19890473      PMCID: PMC2771871          DOI: 10.1590/S0103-50532008000400003

Source DB:  PubMed          Journal:  J Braz Chem Soc        ISSN: 0103-5053            Impact factor:   1.838


  27 in total

Review 1.  Selectivity of potentiometric ion sensors.

Authors:  E Bakker; E Pretsch; P Bühlmann
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Pulsed galvanostatic control of ionophore-based polymeric ion sensors.

Authors:  Alexey Shvarev; Eric Bakker
Journal:  Anal Chem       Date:  2003-09-01       Impact factor: 6.986

3.  Ion-selective supported liquid membranes placed under steady-state diffusion control.

Authors:  Károly Tompa; Karin Birbaum; Adam Malon; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2005-12-01       Impact factor: 6.986

4.  Response characteristics of a reversible electrochemical sensor for the polyion protamine.

Authors:  Alexey Shvarev; Eric Bakker
Journal:  Anal Chem       Date:  2005-08-15       Impact factor: 6.986

5.  Potentiometry at trace levels in confined samples: ion-selective electrodes with subfemtomole detection limits.

Authors:  Adam Malon; Tamas Vigassy; Eric Bakker; Ernö Pretsch
Journal:  J Am Chem Soc       Date:  2006-06-28       Impact factor: 15.419

6.  Backside calibration potentiometry: ion activity measurements with selective supported liquid membranes by calibrating from the inner side of the membrane.

Authors:  Adam Malon; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2007-01-15       Impact factor: 6.986

7.  Potentiometric detection of DNA hybridization.

Authors:  Apon Numnuam; Karin Y Chumbimuni-Torres; Yun Xiang; Ralph Bash; Panote Thavarungkul; Proespichaya Kanatharana; Ernö Pretsch; Joseph Wang; Eric Bakker
Journal:  J Am Chem Soc       Date:  2007-12-20       Impact factor: 15.419

8.  Solid contact potentiometric sensors for trace level measurements.

Authors:  Karin Y Chumbimuni-Torres; Nastassia Rubinova; Aleksandar Radu; Lauro T Kubota; Eric Bakker
Journal:  Anal Chem       Date:  2006-02-15       Impact factor: 6.986

9.  Calcium-selective electrode with liquid ion exchanger.

Authors:  J W Ross
Journal:  Science       Date:  1967-06-09       Impact factor: 47.728

10.  Aptamer-based potentiometric measurements of proteins using ion-selective microelectrodes.

Authors:  Apon Numnuam; Karin Y Chumbimuni-Torres; Yun Xiang; Ralph Bash; Panote Thavarungkul; Proespichaya Kanatharana; Ernö Pretsch; Joseph Wang; Eric Bakker
Journal:  Anal Chem       Date:  2008-01-10       Impact factor: 6.986

View more
  3 in total

1.  Functionalization of micro- and nano-apertures with chromate-selective solvent polymeric membrane.

Authors:  Daniel C Rieck; Bingwen Liu; Bong-Jae Park; David F Moffett; David A Kidwell; Gary J Cheng; Bernard J Van Wie
Journal:  Anal Chim Acta       Date:  2009-11-18       Impact factor: 6.558

2.  Dibenzo-18-crown-6-based carbon paste sensors for the nanomolar potentiometric determination of daclatasvir dihydrochloride: An anti-HCV drug and a potential candidate for treatment of SARS-CoV-2.

Authors:  Yomna M Ahmed; Sayed S Badawy; Fatehy M Abdel-Haleem
Journal:  Microchem J       Date:  2022-02-10       Impact factor: 4.821

3.  In-field determination of soil ion content using a handheld device and screen-printed solid-state ion-selective electrodes.

Authors:  Ron Rosenberg; Michael S Bono; Soumya Braganza; Chintan Vaishnav; Rohit Karnik; A John Hart
Journal:  PLoS One       Date:  2018-09-25       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.