Literature DB >> 5610120

Calcium-selective electrode with liquid ion exchanger.

J W Ross.   

Abstract

A simple calcium-selective electrode has been developed which is capable of measuring calcium ion activity in the presence of many common interfering ions. The electrode utilizes a liquid ion exchanger membrane containing the calcium salt of a disubstituted phosphoric acid.

Entities:  

Mesh:

Substances:

Year:  1967        PMID: 5610120     DOI: 10.1126/science.156.3780.1378

Source DB:  PubMed          Journal:  Science        ISSN: 0036-8075            Impact factor:   47.728


  16 in total

1.  Modern Directions for Potentiometric Sensors.

Authors:  Eric Bakker; Karin Chumbimuni-Torres
Journal:  J Braz Chem Soc       Date:  2008-01-01       Impact factor: 1.838

2.  Continuous clinical monitoring with ion-selective electrodes. A feasible or desirable objective?

Authors:  H F Drake; T Treasure
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

3.  Observations on ionized calcium in the plasma of cows during estrus.

Authors:  M W McLennan; R A Willoughby
Journal:  Can Vet J       Date:  1973-10       Impact factor: 1.008

4.  [Determination of ionized calcium in serum with an ion-selective flow-thru-electrode. Method and normal values].

Authors:  C Fuchs; K Paschen; P G Spieckermann; C von Westberg
Journal:  Klin Wochenschr       Date:  1972-09-01

5.  Physical chemistry of calcium stone formation.

Authors:  A Hodgkinson; B E Nordin
Journal:  Biochem J       Date:  1971-03       Impact factor: 3.857

6.  Calcium binding by chondroitin sulfate.

Authors:  M R Urist; D P Speer; K J Ibsen; B S Strates
Journal:  Calcif Tissue Res       Date:  1968

7.  Continuous in vivo measurement of plasma ionized calcium.

Authors:  R Greger; H Oberleithner; F Lang; H Sporer
Journal:  Pflugers Arch       Date:  1980-03       Impact factor: 3.657

Review 8.  Using fluorometry and ion-sensitive microelectrodes to study the functional expression of heterologously-expressed ion channels and transporters in Xenopus oocytes.

Authors:  Raif Musa-Aziz; Walter F Boron; Mark D Parker
Journal:  Methods       Date:  2010-01-04       Impact factor: 3.608

9.  Ion fluxes across the pulmonary epithelium and the secretion of lung liquid in the foetal lamb.

Authors:  R E Olver; L B Strang
Journal:  J Physiol       Date:  1974-09       Impact factor: 5.182

10.  Dose calcium balanced heparin affect blood gas and electrolyte analysis?

Authors:  R Ochiai; M Nagano
Journal:  J Anesth       Date:  1990-01       Impact factor: 2.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.