Literature DB >> 19865467

Influence of the scattering phase function on light transport measurements in turbid media performed with small source-detector separations.

J R Mourant, J Boyer, A H Hielscher, I J Bigio.   

Abstract

Many methods of optical tissue diagnosis require that measurements be performed with small source-detector separations in a backscatter geometry. Monte Carlo simulations are used to demonstrate that for these situations light transport depends on the exact form of the angular scattering probability distribution, P(theta). Simulations performed with different forms of P(theta) with the same value of ?cos theta? result in the collection of significantly different fractions of the incident photons, particularly when small-numerical-aperture delivery and collection fibers are employed. More photons are collected for the distribution that has a higher probability of scattering events with theta > 125 degrees . For the clinically relevant optical parameters employed here, the differences in light collection are >60%.

Year:  1996        PMID: 19865467     DOI: 10.1364/ol.21.000546

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  21 in total

1.  Lookup-table method for imaging optical properties with structured illumination beyond the diffusion theory regime.

Authors:  Tim A Erickson; Amaan Mazhar; David Cuccia; Anthony J Durkin; James W Tunnell
Journal:  J Biomed Opt       Date:  2010 May-Jun       Impact factor: 3.170

2.  Perturbation Monte Carlo methods for tissue structure alterations.

Authors:  Jennifer Nguyen; Carole K Hayakawa; Judith R Mourant; Jerome Spanier
Journal:  Biomed Opt Express       Date:  2013-09-04       Impact factor: 3.732

3.  Sub-diffusive scattering parameter maps recovered using wide-field high-frequency structured light imaging.

Authors:  Stephen Chad Kanick; David M McClatchy; Venkataramanan Krishnaswamy; Jonathan T Elliott; Keith D Paulsen; Brian W Pogue
Journal:  Biomed Opt Express       Date:  2014-09-03       Impact factor: 3.732

4.  Subdiffuse scattering and absorption model for single fiber reflectance spectroscopy.

Authors:  Anouk L Post; Dirk J Faber; Henricus J C M Sterenborg; Ton G van Leeuwen
Journal:  Biomed Opt Express       Date:  2020-10-22       Impact factor: 3.732

5.  Lookup table-based sampling of the phase function for Monte Carlo simulations of light propagation in turbid media.

Authors:  Peter Naglič; Franjo Pernuš; Boštjan Likar; Miran Bürmen
Journal:  Biomed Opt Express       Date:  2017-02-28       Impact factor: 3.732

6.  System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

Authors:  Ashley M Laughney; Venkataramanan Krishnaswamy; Tyler B Rice; David J Cuccia; Richard J Barth; Bruce J Tromberg; Keith D Paulsen; Brian W Pogue; Wendy A Wells
Journal:  J Biomed Opt       Date:  2013-03       Impact factor: 3.170

Review 7.  Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations.

Authors:  Katherine W Calabro; Irving J Bigio
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

8.  Elastic scattering spectroscopy as an optical marker of inflammatory bowel disease activity and subtypes.

Authors:  Eladio Rodriguez-Diaz; Christopher Atkinson; Lisa I Jepeal; Adam Berg; Christopher S Huang; Sandra R Cerda; Michael J OʼBrien; Irving J Bigio; Francis A Farraye; Satish K Singh
Journal:  Inflamm Bowel Dis       Date:  2014-06       Impact factor: 5.325

9.  The color of cancer: Margin guidance for oral cancer resection using elastic scattering spectroscopy.

Authors:  Gregory A Grillone; Zimmern Wang; Gintas P Krisciunas; Angela C Tsai; Vishnu R Kannabiran; Robert W Pistey; Qing Zhao; Eladio Rodriguez-Diaz; Ousama M A'Amar; Irving J Bigio
Journal:  Laryngoscope       Date:  2017-07-28       Impact factor: 3.325

10.  Microscope objective based 4π spectroscopic tissue scattering goniometry.

Authors:  Z J Simmons; J D Rogers
Journal:  Biomed Opt Express       Date:  2017-07-25       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.