Literature DB >> 23525360

System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

Ashley M Laughney1, Venkataramanan Krishnaswamy, Tyler B Rice, David J Cuccia, Richard J Barth, Bruce J Tromberg, Keith D Paulsen, Brian W Pogue, Wendy A Wells.   

Abstract

The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness of fit, where optical parameters were estimated by minimizing the residual sum of squares between the measured modulation amplitude and its solutions, modeled according to diffusion and scaled-Monte Carlo simulations. In contrast-detail phantoms, a 1.25-mm-diameter surface inclusion was detectable for scattering contrast >28%; a fraction of this scattering contrast (7%) was detectable for a 10 mm surface inclusion and at least 33% scattering contrast was detected up to 1.5 mm below the phantom surface, a probing depth relevant to breast surgical margin assessment. Recovered hemoglobin concentrations were insensitive to changes in scattering, except for overestimation at visible wavelengths for total hemoglobin concentrations <15  μM. The scattering amplitude increased linearly with scattering concentration, but the scattering slope depended on both the particle size and number density. Goodness of fit was comparable for the diffusion and scaled-Monte Carlo models of transport in spatially modulated, near-infrared reflectance acquired from 47 lumpectomy tissues, but recovered absorption parameters varied more linearly with expected hemoglobin concentration in liquid phantoms for the scaled-Monte Carlo forward model. SFDI could potentially reduce the high secondary excision rate associated with breast conserving surgery; its clinical translation further requires reduced image reconstruction time and smart inking strategies.

Mesh:

Year:  2013        PMID: 23525360      PMCID: PMC3605471          DOI: 10.1117/1.JBO.18.3.036012

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  47 in total

1.  Imaging scattering orientation with spatial frequency domain imaging.

Authors:  Soren D Konecky; Tyler Rice; Anthony J Durkin; Bruce J Tromberg
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

2.  Wavelength optimization for rapid chromophore mapping using spatial frequency domain imaging.

Authors:  Amaan Mazhar; Steven Dell; David J Cuccia; Sylvain Gioux; Anthony J Durkin; John V Frangioni; Bruce J Tromberg
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

3.  Optical biopsy of breast tissue using differential path-length spectroscopy.

Authors:  Robert L P van Veen; Arjen Amelink; Marian Menke-Pluymers; Carmen van der Pol; Henricus J C M Sterenborg
Journal:  Phys Med Biol       Date:  2005-05-18       Impact factor: 3.609

4.  Analytical model of light reflectance for extraction of the optical properties in small volumes of turbid media.

Authors:  Roberto Reif; Ousama A'Amar; Irving J Bigio
Journal:  Appl Opt       Date:  2007-10-10       Impact factor: 1.980

5.  Quantifying the properties of two-layer turbid media with frequency-domain diffuse reflectance.

Authors:  T H Pham; T Spott; L O Svaasand; B J Tromberg
Journal:  Appl Opt       Date:  2000-09-01       Impact factor: 1.980

6.  Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics.

Authors:  J R Mourant; J P Freyer; A H Hielscher; A A Eick; D Shen; T M Johnson
Journal:  Appl Opt       Date:  1998-06-01       Impact factor: 1.980

7.  Optical properties of fat emulsions.

Authors:  René Michels; Florian Foschum; Alwin Kienle
Journal:  Opt Express       Date:  2008-04-14       Impact factor: 3.894

Review 8.  Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials.

Authors:  M Clarke; R Collins; S Darby; C Davies; P Elphinstone; V Evans; J Godwin; R Gray; C Hicks; S James; E MacKinnon; P McGale; T McHugh; R Peto; C Taylor; Y Wang
Journal:  Lancet       Date:  2005-12-17       Impact factor: 79.321

9.  Influence of the scattering phase function on light transport measurements in turbid media performed with small source-detector separations.

Authors:  J R Mourant; J Boyer; A H Hielscher; I J Bigio
Journal:  Opt Lett       Date:  1996-04-01       Impact factor: 3.776

10.  Quantitative optical spectroscopy: a robust tool for direct measurement of breast cancer vascular oxygenation and total hemoglobin content in vivo.

Authors:  J Quincy Brown; Lee G Wilke; Joseph Geradts; Stephanie A Kennedy; Gregory M Palmer; Nirmala Ramanujam
Journal:  Cancer Res       Date:  2009-03-17       Impact factor: 12.701

View more
  24 in total

1.  A polarized multispectral imaging system for quantitative assessment of hypertrophic scars.

Authors:  Pejhman Ghassemi; Taryn E Travis; Lauren T Moffatt; Jeffrey W Shupp; Jessica C Ramella-Roman
Journal:  Biomed Opt Express       Date:  2014-09-02       Impact factor: 3.732

2.  Quantitative spatial frequency fluorescence imaging in the sub-diffusive domain for image-guided glioma resection.

Authors:  Mira Sibai; Israel Veilleux; Jonathan T Elliott; Frederic Leblond; Brian C Wilson
Journal:  Biomed Opt Express       Date:  2015-11-19       Impact factor: 3.732

3.  Accelerated rescaling of single Monte Carlo simulation runs with the Graphics Processing Unit (GPU).

Authors:  Owen Yang; Bernard Choi
Journal:  Biomed Opt Express       Date:  2013-10-29       Impact factor: 3.732

4.  Sub-diffusive scattering parameter maps recovered using wide-field high-frequency structured light imaging.

Authors:  Stephen Chad Kanick; David M McClatchy; Venkataramanan Krishnaswamy; Jonathan T Elliott; Keith D Paulsen; Brian W Pogue
Journal:  Biomed Opt Express       Date:  2014-09-03       Impact factor: 3.732

5.  Dual-DMD hyperspectral spatial frequency domain imaging (SFDI) using dispersed broadband illumination with a demonstration of blood stain spectral monitoring.

Authors:  Matthew B Applegate; Samuel S Spink; Darren Roblyer
Journal:  Biomed Opt Express       Date:  2020-12-24       Impact factor: 3.732

6.  Miniature spectral imaging device for wide-field quantitative functional imaging of the morphological landscape of breast tumor margins.

Authors:  Brandon S Nichols; Antonio Llopis; Gregory M Palmer; Samuel S McCachren; Ozlem Senlik; David Miller; Martin A Brooke; Nan M Jokerst; Joseph Geradts; Rachel Greenup; Nimmi Ramanujam
Journal:  J Biomed Opt       Date:  2017-02-01       Impact factor: 3.170

7.  Low-cost compact multispectral spatial frequency domain imaging prototype for tissue characterization.

Authors:  Mohsen Erfanzadeh; Sreyankar Nandy; Patrick D Kumavor; Quing Zhu
Journal:  Biomed Opt Express       Date:  2018-10-17       Impact factor: 3.732

8.  In vivo isolation of the effects of melanin from underlying hemodynamics across skin types using spatial frequency domain spectroscopy.

Authors:  Rolf B Saager; Ata Sharif; Kristen M Kelly; Anthony J Durkin
Journal:  J Biomed Opt       Date:  2016-05-01       Impact factor: 3.170

9.  Preclinical evaluation of spatial frequency domain-enabled wide-field quantitative imaging for enhanced glioma resection.

Authors:  Mira Sibai; Carl Fisher; Israel Veilleux; Jonathan T Elliott; Frederic Leblond; David W Roberts; Brian C Wilson
Journal:  J Biomed Opt       Date:  2017-07-01       Impact factor: 3.170

10.  Wide-field optical spectroscopy system integrating reflectance and spatial frequency domain imaging to measure attenuation-corrected intrinsic tissue fluorescence in radical prostatectomy specimens.

Authors:  Emile Beaulieu; Audrey Laurence; Mirela Birlea; Guillaume Sheehy; Leticia Angulo-Rodriguez; Mathieu Latour; Roula Albadine; Fred Saad; Dominique Trudel; Frédéric Leblond
Journal:  Biomed Opt Express       Date:  2020-03-17       Impact factor: 3.732

View more