Literature DB >> 19859955

Tailored RF pulse for magnetization inversion at ultrahigh field.

Aaron C Hurley1, Ali Al-Radaideh, Li Bai, Uwe Aickelin, Ron Coxon, Paul Glover, Penny A Gowland.   

Abstract

The radiofrequency (RF) transmit field is severely inhomogeneous at ultrahigh field due to both RF penetration and RF coil design issues. This particularly impairs image quality for sequences that use inversion pulses such as magnetization prepared rapid acquisition gradient echo and limits the use of quantitative arterial spin labeling sequences such as flow-attenuated inversion recovery. Here we have used a search algorithm to produce inversion pulses tailored to take into account the heterogeneity of the RF transmit field at 7 T. This created a slice selective inversion pulse that worked well (good slice profile and uniform inversion) over the range of RF amplitudes typically obtained in the head at 7 T while still maintaining an experimentally achievable pulse length and pulse amplitude in the brain at 7 T. The pulses used were based on the frequency offset correction inversion technique, as well as time dilation of functions, but the RF amplitude, frequency sweep, and gradient functions were all generated using a genetic algorithm with an evaluation function that took into account both the desired inversion profile and the transmit field inhomogeneity. Copyright (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2010        PMID: 19859955     DOI: 10.1002/mrm.22167

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

1.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

2.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

3.  The traveling heads: multicenter brain imaging at 7 Tesla.

Authors:  Maximilian N Voelker; Oliver Kraff; Daniel Brenner; Astrid Wollrab; Oliver Weinberger; Moritz C Berger; Simon Robinson; Wolfgang Bogner; Christopher Wiggins; Robert Trampel; Tony Stöcker; Thoralf Niendorf; Harald H Quick; David G Norris; Mark E Ladd; Oliver Speck
Journal:  MAGMA       Date:  2016-04-20       Impact factor: 2.310

4.  Pulsed arterial spin labelling at ultra-high field with a B 1 (+) -optimised adiabatic labelling pulse.

Authors:  Fabian Zimmer; Kieran O'Brien; Steffen Bollmann; Josef Pfeuffer; Keith Heberlein; Markus Barth
Journal:  MAGMA       Date:  2016-04-15       Impact factor: 2.310

5.  Technical feasibility of integrating 7 T anatomical MRI in image-guided radiotherapy of glioblastoma: a preparatory study.

Authors:  Inge Compter; Jurgen Peerlings; Daniëlle B P Eekers; Alida A Postma; Dimo Ivanov; Christopher J Wiggins; Pieter Kubben; Benno Küsters; Pieter Wesseling; Linda Ackermans; Olaf E M G Schijns; Philippe Lambin; Aswin L Hoffmann
Journal:  MAGMA       Date:  2016-03-30       Impact factor: 2.310

6.  Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer functional MRI at 7 T.

Authors:  Alexander J S Beckett; Tetiana Dadakova; Jennifer Townsend; Laurentius Huber; Suhyung Park; David A Feinberg
Journal:  Magn Reson Med       Date:  2020-06-18       Impact factor: 4.668

7.  Intracortical smoothing of small-voxel fMRI data can provide increased detection power without spatial resolution losses compared to conventional large-voxel fMRI data.

Authors:  Anna I Blazejewska; Bruce Fischl; Lawrence L Wald; Jonathan R Polimeni
Journal:  Neuroimage       Date:  2019-01-25       Impact factor: 6.556

Review 8.  Diagnosis of multiple sclerosis through the lens of ultra-high-field MRI.

Authors:  Pascal Sati
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

Review 9.  Analysis strategies for high-resolution UHF-fMRI data.

Authors:  Jonathan R Polimeni; Ville Renvall; Natalia Zaretskaya; Bruce Fischl
Journal:  Neuroimage       Date:  2017-04-29       Impact factor: 6.556

10.  Design and optimization of pulsed Chemical Exchange Saturation Transfer MRI using a multiobjective genetic algorithm.

Authors:  Eriko S Yoshimaru; Edward A Randtke; Mark D Pagel; Julio Cárdenas-Rodríguez
Journal:  J Magn Reson       Date:  2015-12-19       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.