Literature DB >> 19850172

Optimal gradient operation in comprehensive liquid chromatography x liquid chromatography systems with limited orthogonality.

Filippo Bedani1, Wim Th Kok, Hans-Gerd Janssen.   

Abstract

A novel strategy is described for designing optimal second dimension (2D) gradient conditions for a comprehensive two-dimensional liquid chromatography system where the two dimensions are not fully orthogonal. Using the approach developed here, the initial and final organic modifier content values resulting in the highest coverage of separation space can be derived for each 2D gradient run. Theory indicates that these values can be determined by adapting 2D gradient operation to the degree of orthogonality. The new method is tested on a comprehensive two-dimensional liquid chromatography system that uses reversed phase (RP) columns showing different selectivities in the two dimensions. A comparison between analyses carried out using normal and optimized 2D gradients showed that the latter allow a more efficient use of analysis time. This can result either in an improved peak capacity or in decreasing total analysis time, depending on the final goal of the experiment. In the latter scenario, the number of separated peaks is comparable to that obtained using gradients spanning a wide range of organic modifier but, now, in half the time. As test samples complex mixtures of peptides were analyzed.

Year:  2009        PMID: 19850172     DOI: 10.1016/j.aca.2009.06.042

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Authors:  Yuan Huang; Haiwei Gu; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-04-12       Impact factor: 4.759

Review 2.  Multi-dimensional liquid chromatography in proteomics--a review.

Authors:  Xiang Zhang; Aiqin Fang; Catherine P Riley; Mu Wang; Fred E Regnier; Charles Buck
Journal:  Anal Chim Acta       Date:  2010-02-06       Impact factor: 6.558

3.  Peak capacity optimization in comprehensive two dimensional liquid chromatography: a practical approach.

Authors:  Haiwei Gu; Yuan Huang; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-10-31       Impact factor: 4.759

4.  Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC×LC).

Authors:  Haiwei Gu; Yuan Huang; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-07-24       Impact factor: 4.759

5.  Post-polymerization photografting on methacrylate-based monoliths for separation of intact proteins and protein digests with comprehensive two-dimensional liquid chromatography hyphenated with high-resolution mass spectrometry.

Authors:  Rudy J Vonk; Sam Wouters; Andrei Barcaru; Gabriel Vivó-Truyols; Sebastiaan Eeltink; Leo J de Koning; Peter J Schoenmakers
Journal:  Anal Bioanal Chem       Date:  2015-03-24       Impact factor: 4.142

6.  [Size exclusion-reverse liquid column chromatography-mass spectrometry and its application in the identification of post-translationally modified proteins in rat kidney].

Authors:  Jianmin Li; Yue Zhuo; Yida Zhang; Na Li; Jianlin Wu
Journal:  Se Pu       Date:  2021-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.