Literature DB >> 19843716

Evaluation of mechanical heart valve size and function with ECG-gated 64-MDCT.

Troy M LaBounty1, Prachi P Agarwal, Aamer Chughtai, David S Bach, Eric Wizauer, Ella A Kazerooni.   

Abstract

OBJECTIVE: The purpose of our study was to determine whether CT can accurately evaluate mechanical heart valve size and function.
MATERIALS AND METHODS: Sixty-two patients with mechanical valves (37 single-disc, 27 bileaflet; 59 aortic, 5 mitral) were evaluated with ECG-gated 64-MDCT and transthoracic echocardiography; a subset of 10 patients underwent cinefluoroscopy. Two readers independently interpreted each study.
RESULTS: The mean age of the patients was 46.4 +/- 14.4 years; 50 were men and 12 were women. There was excellent correlation, and differences between CT readers were absent to small in measuring the opening angle (r = 0.96, p < 0.001; 76.7 +/- 9.0 degrees vs 76.8 +/- 9.6 degrees , p = 0.73), annulus diameter (r = 0.96, p < 0.001; 25.9 +/- 3.3 vs 25.9 +/- 3.2 mm, p = 0.62), and geometric orifice area (r = 0.98, p < 0.001; 3.8 +/- 0.9 vs 3.6 +/- 0.8 cm(2), p < 0.001). There was strong correlation without difference in opening angle between CT and cinefluoroscopy (r = 0.77, p < 0.001; 79.2 degrees +/- 9.8 degrees vs 77.2 degrees +/- 15.5 degrees , p = 0.45). Compared with manufacturer specifications, CT reported opening angles that were smaller for single-disc valves (n = 36, 67.4 degrees +/- 5.7 degrees vs 75 degrees , p < 0.001) and similar for bileaflet valves (n = 42 for 21 valves, 83.8 degrees +/- 3.9 degrees vs 85 degrees , p = 0.05), valves, with small underestimation with CT versus specifications in annulus diameter (n = 41; r = 0.75, p < 0.001; 26.4 +/- 3.0 vs 27.5 +/- 3.3 mm, p = 0.003), and geometric orifice area (n = 35; r = 0.90, p < 0.001; 3.7 +/- 0.7 vs 3.8 +/- 0.8 cm(2), p = 0.04). Each disc closed fully on CT; none had more than mild regurgitation on echocardiography.
CONCLUSION: CT can measure the size and function of mechanical valves with high interobserver agreement and results similar to specifications. The opening angle with CT strongly correlates with cinefluoroscopy. CT is promising for the assessment of mechanical valves.

Entities:  

Mesh:

Year:  2009        PMID: 19843716     DOI: 10.2214/AJR.08.2178

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  10 in total

Review 1.  Cardiac imaging in valvular heart disease.

Authors:  W S Choo; R P Steeds
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Factors affecting computed tomography image quality for assessment of mechanical aortic valves.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Sae Rom Hong; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-01       Impact factor: 2.357

3.  Left main coronary artery dissection after valve replacement: role of coronary computed tomographic angiography.

Authors:  Majid Kyavar; Hosseinali Bassiri; Anita Sadeghpour; Azin Alizadehasl; Hamidreza Pouraliakbar; Faranak Kargar
Journal:  Tex Heart Inst J       Date:  2012

4.  Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.

Authors:  Young Joo Suh; Young Jin Kim; Sak Lee; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Byoung Wook Choi; Byung-Chul Chang
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-21       Impact factor: 2.357

5.  The impact of a new model-based iterative reconstruction algorithm on prosthetic heart valve related artifacts at reduced radiation dose MDCT.

Authors:  Dominika Suchá; Martin J Willemink; Pim A de Jong; Arnold M R Schilham; Tim Leiner; Petr Symersky; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-29       Impact factor: 2.357

6.  Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

Authors:  Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Jeong A Kim; Jae-Kwan Song; Hwa Jung Kim; Tae-Hwan Lim; Dong Hyun Yang
Journal:  Clin Res Cardiol       Date:  2018-02-19       Impact factor: 5.460

Review 7.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

8.  Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

9.  Impact of Cardiac Computed Tomographic Angiography on Diagnostic and Therapeutic Decisions in Patients with Suspected Prosthetic Heart Valve Dysfunction.

Authors:  Amr Youssef Hassan; Hussien Heshmat Kassem; Hossam Ibrahim Kandil; Marwa Sayed Meshaal; Mohamed Ali Salem; Ahmed Shehata Mohamed
Journal:  J Saudi Heart Assoc       Date:  2021-04-19

10.  Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings.

Authors:  Mi Yeon Park; Hyun Jung Koo; Hojin Ha; Joon-Won Kang; Dong Hyun Yang
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2020-08-03
  10 in total