Theoretical analysis of full-ring multi-pinhole brain SPECT.

M C Goorden1, M C M Rentmeester, F J Beekman.   

Abstract

Presently used clinical brain SPECT suffers from limited spatio-temporal resolution. Here we investigate the feasibility of high-resolution and high-sensitivity full-ring multi-pinhole brain SPECT (MP-SPECT). Using an analytical model we optimized pinhole-detector geometries of MP-SPECT for different detector intrinsic resolutions R(i). System resolution and sensitivity of optimized MP-SPECT were compared to conventional clinical SPECT. The comparison of the system resolution of different systems was done at matched sensitivity, which was achieved by tuning pinhole diameters. Similarly, sensitivities were compared at matched system resolution. For MP-SPECT that uses detectors with intrinsic resolutions of 4 mm > R(i) 0.5 mm a sensitivity can be achieved that is 6.0 times higher than the sensitivity of conventional dual-head SPECT systems with parallel-hole collimators (DualPar), while system resolution can be improved by a factor of 2.4. To achieve these improvements a large detector-to-collimator distance is needed. In contrast, for detectors with intrinsic resolutions <0.2 mm, it is beneficial to place the detectors close to the pinholes, resulting in a high number of de-magnified projections. For a detector intrinsic resolution of 0.05 mm, a 14.5-fold improvement in sensitivity and a 3.8-fold improvement in system resolution compared to DualPar is predicted. Furthermore, we found that for optimized MP-SPECT the sensitivity scales proportionally to system resolution squared, with the proportionality constant depending on R(i). From our sensitivity-system resolution trade-off equations we deduced that MP-SPECT with an ideal detector (R(i) --> 0) can have a system resolution that is 2.0 times better than optimized MP-SPECT with a conventional detector (R(i) approximately 3 mm). The high performance of optimized MP-SPECT may open up completely new molecular imaging applications.

Mesh:

Substances:

Year:  2009        PMID: 19826198     DOI: 10.1088/0031-9155/54/21/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

Review 1.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 2.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

Review 3.  SPECT detectors: the Anger Camera and beyond.

Authors:  Todd E Peterson; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2011-08-09       Impact factor: 3.609

4.  Multipinhole collimator with 20 apertures for a brain SPECT application.

Authors:  Tzu-Cheng Lee; Justin R Ellin; Qiu Huang; Uttam Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Design of a Multi-Pinhole Collimator for I-123 DaTscan Imaging on Dual-Headed SPECT Systems in Combination with a Fan-Beam Collimator.

Authors:  Michael A King; Joyeeta M Mukherjee; Arda Könik; I George Zubal; Joyoni Dey; Robert Licho
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-03       Impact factor: 1.679

6.  Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Arda Konik; Timothy J Fromme; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

7.  Advances in preclinical SPECT instrumentation.

Authors:  Todd E Peterson; Sepideh Shokouhi
Journal:  J Nucl Med       Date:  2012-05-14       Impact factor: 10.057

8.  Cerebral SPECT imaging with different acquisition schemes using varying levels of multiplexing versus sensitivity in an adaptive multi-pinhole brain-dedicated scanner.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Micaehla May; R Garrett Richards; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  Biomed Phys Eng Express       Date:  2021-09-22

9.  Development of clinical simultaneous SPECT/MRI.

Authors:  Brian F Hutton; Michele Occhipinti; Andre Kuehne; Domokos Máthé; Noémi Kovács; Helmar Waiczies; Kjell Erlandsson; Debora Salvado; Marco Carminati; Giovanni L Montagnani; Susan C Short; Luisa Ottobrini; Pieter van Mullekom; Claudio Piemonte; Tamas Bukki; Zoltan Nyitrai; Zoltan Papp; Kalman Nagy; Thoralf Niendorf; Irene de Francesco; Carlo Fiorini
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.