Literature DB >> 19813425

Effect of implants on maximum bite force in edentulous patients.

Mansour Rismanchian1, Farshad Bajoghli, Zahra Mostajeran, Akbar Fazel, P sadr Eshkevari.   

Abstract

One of the main goals of prosthetic dentistry is to reconstruct the masticatory system. Replacing missing teeth by complete or partial denture is associated with decreased bite force and patient satisfaction. The aim of the present study was to measure the maximum bite force (MBF) and to evaluate patients' satisfaction from their conventional complete dentures and their mandibular implant-supported overdentures opposed by complete denture. In this cross sectional analytical descriptive study, seventy-five 45- to 65-year-old patients were divided into 3 groups wearing: (1) conventional complete dentures for up to 6 months; (2) conventional complete dentures for 10 years or more; and (3) complete maxillary dentures opposing mandibular implant-supported overdentures. Bite force was measured by means of electronic bite force measuring device with strain gauges. Three measurements were made on each side on the first molar region and the mean values were recorded. Patient satisfaction was also recorded using questionnaires. Results were analyzed by analysis of variance (ANOVA), t test, chi-square, and Pearson correlation test. The mean MBF for the first, the second, and the third group was, respectively, 5.65 +/- 1.46 kgf, 7.01 +/- 2.1 kgf, and 12.22 +/- 27 kgf. The difference between MBF in patients with overdentures and in patients with conventional complete dentures was statistically significant (P = .001). Patient satisfaction with mandibular implant-supported overdentures was recorded as "great." Results indicated MBF in the patients with mandibular implant-supported overdentures was significantly higher than that of patients with conventional complete dentures. This difference may indicate the important role of dental implants in the improvement of bite force and chewing efficiency and therefore patients' satisfaction.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19813425     DOI: 10.1563/1548-1336-35.4.196

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  5 in total

1.  Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading.

Authors:  Sarah C Woodford; Dale L Robinson; Cornelia Edelmann; Albert Mehl; Oliver Röhrle; Peter Vee Sin Lee; David C Ackland
Journal:  Ann Biomed Eng       Date:  2021-01-06       Impact factor: 3.934

2.  Influence of implant number, length, and tilting degree on stress distribution in atrophic maxilla: a finite element study.

Authors:  Zeynep Gümrükçü; Yavuz Tolga Korkmaz
Journal:  Med Biol Eng Comput       Date:  2017-11-09       Impact factor: 2.602

3.  Mandibular implant-supported overdentures in (frail) elderly: A prospective study with 20-year follow-up.

Authors:  Mieke H Bakker; Arjan Vissink; Henny J A Meijer; Gerry M Raghoebar; Anita Visser
Journal:  Clin Implant Dent Relat Res       Date:  2019-04-16       Impact factor: 3.932

4.  Evaluation of patient satisfaction and masticatory performance in mandible single implant-assisted overdenture.

Authors:  Swati Kashyap; Sanjeev Mittal; Navneet Sharma; Urvashi Sukhija; Mohit Kamra; Nitika Gupta
Journal:  Tzu Chi Med J       Date:  2021-04-05

5.  The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material.

Authors:  Nick Polychronakis; Aspasia Sarafianou; Alcibiadis Zissis; Triantafillos Papadopoulos
Journal:  Acta Stomatol Croat       Date:  2017-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.