Literature DB >> 19800011

In vivo detection of individual glomeruli in the rodent olfactory bulb using manganese enhanced MRI.

Kai-Hsiang Chuang1, Leonardo Belluscio, Alan P Koretsky.   

Abstract

MRI contrast based on relaxation times, proton density, or signal phase have been applied to delineate neural structures in the brain. However, neural units such as cortical layers and columns have been difficult to identify using these methods. Manganese ion delivered either systemically or injected directly has been shown to accumulate specifically within cellular areas of the brain enabling the differentiation of layers within the hippocampus, cortex, cerebellum, and olfactory bulb in vivo. Here we show the ability to detect individual olfactory glomeruli using manganese enhanced MRI (MEMRI). Glomeruli are anatomically distinct structures ( approximately 150 microm in diameter) on the surface of the olfactory bulb that represent the first processing units for olfactory sensory information. Following systemic delivery of MnCl(2) we used 3D-MRI with 50 microm isotropic resolution to detect discrete spots of increased signal intensity between 100 and 200 microm in diameter in the glomerular layer of the rat olfactory bulb. Inflow effects of arterial blood and susceptibility effects of venous blood were suppressed and were evaluated by comparing the location of vessels in the bulb to areas of manganese enhancement using iron oxide to increase vessel contrast. These potential vascular effects did not explain the contrast detected. Nissl staining of individual glomeruli were also compared to MEMRI images from the same animals clearly demonstrating that many of the manganese enhanced regions corresponded to individual olfactory glomeruli. Thus, MEMRI can be used as a non-invasive means to detect olfactory glomeruli for longitudinal studies looking at neural plasticity during olfactory development or possible degeneration associated with disease.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19800011      PMCID: PMC2789874          DOI: 10.1016/j.neuroimage.2009.09.060

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  43 in total

1.  Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter van Gelderen; Jerzy Bodurka; Renxin Chu; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Detection of entorhinal layer II using 7Tesla [corrected] magnetic resonance imaging.

Authors:  Jean C Augustinack; Andre J W van der Kouwe; Megan L Blackwell; David H Salat; Christopher J Wiggins; Matthew P Frosch; Graham C Wiggins; Andreas Potthast; Lawrence L Wald; Bruce R Fischl
Journal:  Ann Neurol       Date:  2005-04       Impact factor: 10.422

3.  Extensive heterogeneity in white matter intensity in high-resolution T2*-weighted MRI of the human brain at 7.0 T.

Authors:  Tie-Qiang Li; Peter van Gelderen; Hellmut Merkle; Lalith Talagala; Alan P Koretsky; Jeff Duyn
Journal:  Neuroimage       Date:  2006-07-18       Impact factor: 6.556

4.  Enhanced T2 contrast for MR histology of the mouse brain.

Authors:  Anjum Ali Sharief; G Allan Johnson
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

5.  High-field MRI of brain cortical substructure based on signal phase.

Authors:  Jeff H Duyn; Peter van Gelderen; Tie-Qiang Li; Jacco A de Zwart; Alan P Koretsky; Masaki Fukunaga
Journal:  Proc Natl Acad Sci U S A       Date:  2007-06-22       Impact factor: 11.205

6.  Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain.

Authors:  John C Nouls; Michael G Izenson; Harold P Greeley; G Allan Johnson
Journal:  J Magn Reson       Date:  2008-01-05       Impact factor: 2.229

7.  Magnetic resonance imaging of cortical connectivity in vivo.

Authors:  S Canals; M Beyerlein; A L Keller; Y Murayama; N K Logothetis
Journal:  Neuroimage       Date:  2008-01-28       Impact factor: 6.556

8.  Performance of a 200-MHz cryogenic RF probe designed for MRI and MRS of the murine brain.

Authors:  David Ratering; Christof Baltes; Jurek Nordmeyer-Massner; Daniel Marek; Markus Rudin
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

9.  Manganese enhanced MRI reveals functional circuitry in response to odorant stimuli.

Authors:  Kai-Hsiang Chuang; Jung Hee Lee; Afonso C Silva; Leonardo Belluscio; Alan P Koretsky
Journal:  Neuroimage       Date:  2008-09-24       Impact factor: 6.556

10.  Detection of cortical laminar architecture using manganese-enhanced MRI.

Authors:  Afonso C Silva; Jung Hee Lee; Carolyn W-H Wu; Jason Tucciarone; Galit Pelled; Ichio Aoki; Alan P Koretsky
Journal:  J Neurosci Methods       Date:  2007-09-02       Impact factor: 2.390

View more
  14 in total

Review 1.  Is there a path beyond BOLD? Molecular imaging of brain function.

Authors:  Alan P Koretsky
Journal:  Neuroimage       Date:  2012-03-03       Impact factor: 6.556

Review 2.  Visualizing odor representation in the brain: a review of imaging techniques for the mapping of sensory activity in the olfactory glomeruli.

Authors:  F Pain; B L'heureux; H Gurden
Journal:  Cell Mol Life Sci       Date:  2011-05-17       Impact factor: 9.261

3.  Magnetic resonance imaging of odorant activity-dependent migration of neural precursor cells and olfactory bulb growth.

Authors:  Nikorn Pothayee; Diana M Cummings; Timothy J Schoenfeld; Stephen Dodd; Heather A Cameron; Leonardo Belluscio; Alan P Koretsky
Journal:  Neuroimage       Date:  2017-06-30       Impact factor: 6.556

Review 4.  Foundations of layer-specific fMRI and investigations of neurophysiological activity in the laminarized neocortex and olfactory bulb of animal models.

Authors:  Alexander John Poplawsky; Mitsuhiro Fukuda; Seong-Gi Kim
Journal:  Neuroimage       Date:  2017-05-12       Impact factor: 6.556

Review 5.  Novel frontiers in ultra-structural and molecular MRI of the brain.

Authors:  Jeff H Duyn; Alan P Koretsky
Journal:  Curr Opin Neurol       Date:  2011-08       Impact factor: 5.710

6.  Layer-dependent BOLD and CBV-weighted fMRI responses in the rat olfactory bulb.

Authors:  Alexander John Poplawsky; Seong-Gi Kim
Journal:  Neuroimage       Date:  2014-01-10       Impact factor: 6.556

7.  Laminar specific detection of APP induced neurodegeneration and recovery using MEMRI in an olfactory based Alzheimer's disease mouse model.

Authors:  Galit Saar; Ning Cheng; Leonardo Belluscio; Alan P Koretsky
Journal:  Neuroimage       Date:  2015-05-27       Impact factor: 6.556

8.  Engineered mitochondrial ferritin as a magnetic resonance imaging reporter in mouse olfactory epithelium.

Authors:  Bistra Iordanova; T Kevin Hitchens; Clinton S Robison; Eric T Ahrens
Journal:  PLoS One       Date:  2013-08-30       Impact factor: 3.240

Review 9.  Manganese-Enhanced Magnetic Resonance Imaging: Overview and Central Nervous System Applications With a Focus on Neurodegeneration.

Authors:  Ryan A Cloyd; Shon A Koren; Jose F Abisambra
Journal:  Front Aging Neurosci       Date:  2018-12-13       Impact factor: 5.750

10.  Brain processing of biologically relevant odors in the awake rat, as revealed by manganese-enhanced MRI.

Authors:  Benoist Lehallier; Olivier Rampin; Audrey Saint-Albin; Nathalie Jérôme; Christian Ouali; Yves Maurin; Jean-Marie Bonny
Journal:  PLoS One       Date:  2012-10-31       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.