Literature DB >> 18421696

Performance of a 200-MHz cryogenic RF probe designed for MRI and MRS of the murine brain.

David Ratering1, Christof Baltes, Jurek Nordmeyer-Massner, Daniel Marek, Markus Rudin.   

Abstract

A cryogenic 200-MHz RF transmit/receive probe (CryoProbe) made of copper and designed for murine brain studies is described. The probe operates at 30K and its performance was compared to a home-made surface coil of equal dimensions and a mouse head volume resonator, both operating at room temperature (RT). Since for small volumes of tissue interrogated (<5 mL) sample noise and thermal noise of the receiver are of comparable magnitude, considerable noise reduction can be achieved by cooling of the receiver system, e.g., using cold helium gas. The effect of temperature lowering on the signal-to-noise ratio (SNR) was assessed in phantom and in vivo murine brain studies using conventional MRI sequences (spin and gradient echo) and single voxel MR spectroscopy. Consistent sensitivity increases were observed for the CryoProbe. SNR increases by a factor>or=2 for the phantom experiments and by factors of 1.8 to 1.9 for in vivo experiments when compared to the RT surface coil for both MRI and MRS experiments. These results are in good agreement with estimated SNR gains for a circular surface coil probe cooled to 30K. The use of a cryogenic probe represents an economically attractive option to enhance the sensitivity in small animal MRI/MRS. Copyright (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18421696     DOI: 10.1002/mrm.21629

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.

Authors:  Paula Ramos Delgado; Ekkehard Küstermann; André Kühne; Jason M Millward; Thoralf Niendorf; Andreas Pohlmann; Martin Meier
Journal:  Methods Mol Biol       Date:  2021

2.  On the magnetic field dependence of deuterium metabolic imaging.

Authors:  Robin A de Graaf; Arjan D Hendriks; Dennis W J Klomp; Chathura Kumaragamage; Dimitri Welting; Catalina S Arteaga de Castro; Peter B Brown; Scott McIntyre; Terence W Nixon; Jeanine J Prompers; Henk M De Feyter
Journal:  NMR Biomed       Date:  2019-12-26       Impact factor: 4.044

3.  A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil.

Authors:  Chiwan Koo; Richard F Godley; Jaewon Park; Mary P McDougall; Steven M Wright; Arum Han
Journal:  Lab Chip       Date:  2011-05-23       Impact factor: 6.799

4.  Accurate assessment of carotid artery stenosis in atherosclerotic mice using accelerated high-resolution 3D magnetic resonance angiography.

Authors:  David Ratering; Christof Baltes; Christine Lohmann; Christian M Matter; Markus Rudin
Journal:  MAGMA       Date:  2010-09-23       Impact factor: 2.310

5.  Ultra-Slow Single-Vessel BOLD and CBV-Based fMRI Spatiotemporal Dynamics and Their Correlation with Neuronal Intracellular Calcium Signals.

Authors:  Yi He; Maosen Wang; Xuming Chen; Rolf Pohmann; Jonathan R Polimeni; Klaus Scheffler; Bruce R Rosen; David Kleinfeld; Xin Yu
Journal:  Neuron       Date:  2018-02-21       Impact factor: 17.173

6.  In vivo high-resolution diffusion tensor imaging of the mouse brain.

Authors:  Dan Wu; Jiadi Xu; Michael T McMahon; Peter C M van Zijl; Susumu Mori; Frances J Northington; Jiangyang Zhang
Journal:  Neuroimage       Date:  2013-06-12       Impact factor: 6.556

7.  In vivo detection of individual glomeruli in the rodent olfactory bulb using manganese enhanced MRI.

Authors:  Kai-Hsiang Chuang; Leonardo Belluscio; Alan P Koretsky
Journal:  Neuroimage       Date:  2009-09-30       Impact factor: 6.556

8.  Functional and morphological cardiac magnetic resonance imaging of mice using a cryogenic quadrature radiofrequency coil.

Authors:  Babette Wagenhaus; Andreas Pohlmann; Matthias Alexander Dieringer; Antje Els; Helmar Waiczies; Sonia Waiczies; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  PLoS One       Date:  2012-08-01       Impact factor: 3.240

9.  Fast diffusion tensor magnetic resonance imaging of the mouse brain at ultrahigh-field: aiming at cohort studies.

Authors:  Hans-Peter Müller; Ina Vernikouskaya; Albert C Ludolph; Jan Kassubek; Volker Rasche
Journal:  PLoS One       Date:  2012-12-28       Impact factor: 3.240

10.  Thromboembolic stroke in C57BL/6 mice monitored by 9.4 T MRI using a 1H cryo probe.

Authors:  Friederike L Langhauser; Patrick M Heiler; Saskia Grudzenski; Andreas Lemke; Angelika Alonso; Lothar R Schad; Michael G Hennerici; Stephen Meairs; Marc Fatar
Journal:  Exp Transl Stroke Med       Date:  2012-09-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.