Literature DB >> 19783496

Noise reduction in computed tomography scans using 3-d anisotropic hybrid diffusion with continuous switch.

Adriënne M Mendrik1, Evert-Jan Vonken, Annemarieke Rutten, Max A Viergever, Bram van Ginneken.   

Abstract

Noise filtering techniques that maintain image contrast while decreasing image noise have the potential to optimize the quality of computed tomography (CT) images acquired at reduced radiation dose. In this paper, a hybrid diffusion filter with continuous switch (HDCS) is introduced, which exploits the benefits of three-dimensional edge-enhancing diffusion (EED) and coherence-enhancing diffusion (CED). Noise is filtered, while edges, tubular structures, and small spherical structures are preserved. From ten high dose thorax CT scans, acquired at clinical doses, ultra low dose ( 15 mAs ) scans were simulated and used to evaluate and compare HDCS to other diffusion filters, such as regularized Perona-Malik diffusion and EED. Quantitative results show that the HDCS filter outperforms the other filters in restoring the high dose CT scan from the corresponding simulated low dose scan. A qualitative evaluation was performed on filtered real low dose CT thorax scans. An expert observer scored artifacts as well as fine structures and was asked to choose one of three scans (two filtered (blinded), one unfiltered) for three different settings (trachea, lung, and mediastinal). Overall, the HDCS filtered scan was chosen most often.

Entities:  

Mesh:

Year:  2009        PMID: 19783496     DOI: 10.1109/TMI.2009.2022368

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  13 in total

1.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 2.  Survey on Liver Tumour Resection Planning System: Steps, Techniques, and Parameters.

Authors:  Omar Ibrahim Alirr; Ashrani Aizzuddin Abd Rahni
Journal:  J Digit Imaging       Date:  2020-04       Impact factor: 4.056

3.  Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

Authors:  Yang Gao; Zhaoying Bian; Jing Huang; Yunwan Zhang; Shanzhou Niu; Qianjin Feng; Wufan Chen; Zhengrong Liang; Jianhua Ma
Journal:  Opt Express       Date:  2014-06-16       Impact factor: 3.894

4.  Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method.

Authors:  Yinghua Tao; Guang-Hong Chen; Timothy A Hacker; Amish N Raval; Michael S Van Lysel; Michael A Speidel
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

5.  Inference of Cerebrovascular Topology With Geodesic Minimum Spanning Trees.

Authors:  Stefano Moriconi; Maria A Zuluaga; H Rolf Jager; Parashkev Nachev; Sebastien Ourselin; M Jorge Cardoso
Journal:  IEEE Trans Med Imaging       Date:  2018-07-26       Impact factor: 10.048

6.  Low-dose computed tomography image reconstruction via a multistage convolutional neural network with autoencoder perceptual loss network.

Authors:  Qing Li; Saize Li; Runrui Li; Wei Wu; Yunyun Dong; Juanjuan Zhao; Yan Qiang; Rukhma Aftab
Journal:  Quant Imaging Med Surg       Date:  2022-03

7.  Confident texture-based laryngeal tissue classification for early stage diagnosis support.

Authors:  Sara Moccia; Elena De Momi; Marco Guarnaschelli; Matteo Savazzi; Andrea Laborai; Luca Guastini; Giorgio Peretti; Leonardo S Mattos
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-29

8.  Adaptively Tuned Iterative Low Dose CT Image Denoising.

Authors:  SayedMasoud Hashemi; Narinder S Paul; Soosan Beheshti; Richard S C Cobbold
Journal:  Comput Math Methods Med       Date:  2015-05-24       Impact factor: 2.238

9.  An automated liver tumour segmentation from abdominal CT scans for hepatic surgical planning.

Authors:  Omar Ibrahim Alirr; Ashrani Aizzuddin Abd Rahni; Ehsan Golkar
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-02       Impact factor: 2.924

10.  Accurate sparse-projection image reconstruction via nonlocal TV regularization.

Authors:  Yi Zhang; Weihua Zhang; Jiliu Zhou
Journal:  ScientificWorldJournal       Date:  2014-01-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.