Literature DB >> 19781473

Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus.

Caroline Dauwe1, David Touboul, Cynthia J Roberts, Ashraf M Mahmoud, Julien Kérautret, Pierre Fournier, François Malecaze, Joseph Colin.   

Abstract

PURPOSE: To evaluate the biomechanical and morphological changes in keratoconic corneas after Intacs intrastromal corneal ring segment (ICRS) implantation.
SETTING: Department of Ophthalmology, National Reference Center for Keratoconus, Bordeaux University, Bordeaux, France.
METHODS: Keratoconic eyes were retrospectively analyzed after ICRS implantation; preoperative and 6-month postoperative evaluation were done using the Ocular Response Analyzer (ORA) and the Orbscan II topographer. Biomechanical parameters included corneal hysteresis (CH), the corneal resistance factor (CRF), and other parameters extracted from the signal curves. Morphological parameters included simulated keratometry and the cone location magnitude index from the axial map (aCLMI) and tangential map (tCLMI). Parameters were extracted using software designed to read and process topographic maps.
RESULTS: There were no significant differences between preoperatively and postoperatively in mean CH (7.7 mm Hg +/- 1.4 [SD] versus 7.4 +/- 1.4 mm Hg) or mean CRF (6.6 +/- 1.8 mm Hg versus 6.1 +/- 1.4 mm Hg). Only 2 ORA signal parameters were significantly different. Topographic parameters with significant decreases were minimum central keratometry (K) (mean change -5.8 +/- 2.9 diopters [D]) (P<.001), minimum central K (mean change -5.8 +/- 2.3 D) (P<.001), mean aCLMI (9.6 +/- 2.7 preoperatively versus 7.7 +/- 2.5 postoperatively) (P<.009), and mean tCLMI (18.9 +/- 2.8 versus 12.9 +/- 4.4) (P<.002). The only significant correlation between biomechanical and topographic parameters was postoperative ORA infrared signal peak 1 and postoperative aCLMI.
CONCLUSIONS: Intrastromal corneal ring implantation significantly decreased corneal curvature, with preoperative values predicting magnitude of change. However, it did not alter the viscoelastic biomechanical parameters of CH and CRF.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19781473     DOI: 10.1016/j.jcrs.2009.05.033

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  16 in total

1.  Clinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients.

Authors:  Leonardo Torquetti; Guilherme Ferrara; Franklin Almeida; Leandro Cunha; Paulo Ferrara; Jesús Merayo-Lloves
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

2.  Outcome of complete intrastromal ring implantation using femtosecond laser in pellucid marginal degeneration.

Authors:  M Jabbarvand; H Hashemian; M Khodaparast; F Bazvand; A Beheshtnejad
Journal:  Eye (Lond)       Date:  2015-03-27       Impact factor: 3.775

3.  Influence of intrastromal corneal ring segment implantation on corneal biomechanical parameters in keratoconic eyes.

Authors:  Ebru Gorgun; Raciha Beril Kucumen; Nursal Melda Yenerel
Journal:  Jpn J Ophthalmol       Date:  2011-07-16       Impact factor: 2.447

Review 4.  Biomechanics of corneal ectasia and biomechanical treatments.

Authors:  Cynthia J Roberts; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2014-04-26       Impact factor: 3.351

5.  Characterization of cone size and centre in keratoconic corneas.

Authors:  Ashkan Eliasy; Ahmed Abass; Bernardo T Lopes; Riccardo Vinciguerra; Haixia Zhang; Paolo Vinciguerra; Renato Ambrósio; Cynthia J Roberts; Ahmed Elsheikh
Journal:  J R Soc Interface       Date:  2020-08-05       Impact factor: 4.118

6.  Surgical technique: coupling of intrastromal corneal ring segments for ectatic corneal disorders in eye bank corneas.

Authors:  Majid Moshirfar; Maylon Hsu; Yousuf M Khalifa
Journal:  Clin Ophthalmol       Date:  2011-10-10

7.  Corneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature.

Authors:  Majid Moshirfar; Jason N Edmonds; Nicholas L Behunin; Steven M Christiansen
Journal:  Oman J Ophthalmol       Date:  2013-01

8.  Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments.

Authors:  Sergio Ortiz; Pablo Pérez-Merino; Nicolas Alejandre; E Gambra; I Jimenez-Alfaro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2012-04-02       Impact factor: 3.732

9.  Intrastromal corneal ring segments for management of keratoconus.

Authors:  Sri Ganesh; Rohit Shetty; Sharon D'Souza; Sarika Ramachandran; Mathew Kurian
Journal:  Indian J Ophthalmol       Date:  2013-08       Impact factor: 1.848

Review 10.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.