Literature DB >> 25853393

Outcome of complete intrastromal ring implantation using femtosecond laser in pellucid marginal degeneration.

M Jabbarvand1, H Hashemian1, M Khodaparast1, F Bazvand1, A Beheshtnejad1.   

Abstract

PURPOSE: To evaluate the effect of complete intrastromal corneal ring implantations on patients with pellucid marginal degeneration (PMD).
DESIGN: Prospective interventional case series. PATIENTS AND METHODS: Thirty-three eyes with PMD were included into the study. After pocket creation with femtosecond laser (Femtec; 20/10 PerfectVision), MyoRing implantation was performed. Uncorrected and corrected distance visual acuity (UDVA, CDVA), subjective refraction, keratometry, central corneal thickness, corneal biomechanical profile (Ocular Response Analysis), and whole-eye wavefront aberrometry (iTrace) were evaluated preoperatively and also postoperatively, 1 month, 3 months, 6 months, and 1 year after the operation.
RESULTS: One month after surgery, significant improvements were observed in UDVA (ANOVA; P=0.02), mean keratometry, sphere (ANOVA; P <0.001), and cylinder (ANOVA; P=0.04) with no significant changes afterwards. No significant change occurred in the corneal biomechanical profile. Primary coma and trefoil reduced after 1 year (ANOVA; P values were 0.02 and 0.06, respectively). Primary spherical aberration significantly increased according to the 1-year follow-up (ANOVA; P<0.001). No significant complication was observed.
CONCLUSION: MyoRing is considered as a treatment modality for spherocylindrical correction in patients with PMD, with an acceptable safety and efficacy profile.

Entities:  

Mesh:

Year:  2015        PMID: 25853393      PMCID: PMC4469665          DOI: 10.1038/eye.2015.33

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  28 in total

1.  Surgical treatment of pellucid marginal degeneration associated with cataract.

Authors:  M E Rodríguez-Gonzáles-Herrero; A R Ortega; J M Mora-Figueroa
Journal:  J Cataract Refract Surg       Date:  2000-03       Impact factor: 3.351

2.  Vector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.

Authors:  Nienke Visser; Tos T J M Berendschot; Noël J C Bauer; Rudy M M A Nuijts
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-06       Impact factor: 4.799

3.  Corneal biomechanical changes after intracorneal ring segment implantation in keratoconus.

Authors:  David P Piñero; Jorge L Alio; Rafael I Barraquer; Ralph Michael
Journal:  Cornea       Date:  2012-05       Impact factor: 2.651

4.  Continuous intracorneal ring implantation for keratoconus using a femtosecond laser.

Authors:  Mahmoud Jabbarvand; Ahmad Salamatrad; Hesam Hashemian; Mehdi Mazloumi; Mehdi Khodaparast
Journal:  J Cataract Refract Surg       Date:  2013-05-22       Impact factor: 3.351

5.  Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population.

Authors:  Mahmoud Jabbarvand; Ahmad Salamatrad; Hesam Hashemian; Mehdi Khodaparast
Journal:  Am J Ophthalmol       Date:  2013-01-19       Impact factor: 5.258

6.  A single 210-degree arc length intrastromal corneal ring implantation for the management of pellucid marginal corneal degeneration.

Authors:  Anil Kubaloglu; Esin Sogutlu Sari; Yasin Cinar; Arif Koytak; Ekrem Kurnaz; David P Piñero; Yusuf Ozerturk
Journal:  Am J Ophthalmol       Date:  2010-06-08       Impact factor: 5.258

7.  Intracorneal continuous ring implantation for keratoconus: One-year follow-up.

Authors:  Albert Daxer; Haifa Mahmoud; Rengaswamy Srinivasan Venkateswaran
Journal:  J Cataract Refract Surg       Date:  2010-08       Impact factor: 3.351

8.  Surgical treatment of advanced pellucid marginal degeneration.

Authors:  K Rasheed; Y S Rabinowitz
Journal:  Ophthalmology       Date:  2000-10       Impact factor: 12.079

9.  Management of pellucid marginal corneal degeneration with rigid gas permeable contact lenses.

Authors:  Viswanadh B Kompella; Murali K Aasuri; Gullapalli N Rao
Journal:  CLAO J       Date:  2002-07

10.  INTACS inserts using the femtosecond laser compared to the mechanical spreader in the treatment of keratoconus.

Authors:  Yaron S Rabinowitz; Xiaohui Li; Teresa S Ignacio; Ezra Maguen
Journal:  J Refract Surg       Date:  2006-10       Impact factor: 3.573

View more
  2 in total

1.  Clinical outcomes after implantation of a new intrastromal corneal ring with 140-degree of arc in patients with corneal ectasia.

Authors:  Jordana Sandes; Larissa R S Stival; Marcos Pereira de Ávila; Paulo Ferrara; Guilherme Ferrara; Leopoldo Magacho; Luana P N Araújo; Leonardo Torquetti
Journal:  Int J Ophthalmol       Date:  2018-05-18       Impact factor: 1.779

2.  Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation.

Authors:  Mahmoud Jabbarvand; Mehdi Khodaparast; Alireza Jamali; Hooman Ahmadzadeh; Soodeh Bordbar
Journal:  J Curr Ophthalmol       Date:  2021-03-26
  2 in total