Literature DB >> 19781458

Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept.

Jorge L Alió1, Joshua Ben-nun, José L Rodríguez-Prats, Ana B Plaza.   

Abstract

PURPOSE: To evaluate visual outcomes and accommodative gains 1 year after implantation of the NuLens accommodating intraocular lens (IOL).
SETTING: Department of Refractive Surgery, Vissum Corp., Alicante, Spain.
METHODS: This study comprised patients with cataract and atrophic macular degeneration. In each patient, the accommodating IOL was implanted in the eye with the worse visual acuity. At the 12-month follow-up visit, visual acuity and accommodation were measured to determine the efficacy of the IOL. Ultrasound biomicroscopy was used to measure accommodative amplitude.
RESULTS: Ten eyes of 10 patients were evaluated. The mean number of lines patients could read increased from 1.0 preoperatively to 3.8 lines 6 months postoperatively, indicating improvement in uncorrected near visual acuity after IOL implantation. The mean change in cross-section measurements of the IOL was 0.06 mm at 1 month; the value peaked at 3 months (0.21 mm), after which it decreased steadily, becoming stable at 9 months (0.09 mm, which is equivalent to 10.00 diopters [D] of accommodation). Corrected near visual acuity improved slightly (0.7 Jaeger lines) at 12 months, with the best reading distance at 10 cm. These results suggest that the near and distance visual acuities were approximately equal and, therefore, the IOL can produce accommodation of 10.00 D.
CONCLUSIONS: The accommodation mechanism of the IOL can produce an ocular power variation of 10.00 D. Near visual acuity improved without compromising distance visual acuity.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19781458     DOI: 10.1016/j.jcrs.2009.04.043

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

Review 1.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

Review 2.  Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

Authors:  Javier Tomás-Juan; Ane Murueta-Goyena Larrañaga
Journal:  J Optom       Date:  2014-09-22

3.  Introduction of lens-angle reconstruction surgery in rabbit eyes.

Authors:  Min Hee Kim; Ho Sik Hwang; Kyoung Jin Park; Je Hyung Hwang; Choun Ki Joo
Journal:  Korean J Ophthalmol       Date:  2014-11-19

4.  Deformable Surface Accommodating Intraocular Lens: Second Generation Prototype Design Methodology and Testing.

Authors:  Sean J McCafferty; Jim T Schwiegerling
Journal:  Transl Vis Sci Technol       Date:  2015-04-28       Impact factor: 3.283

Review 5.  Refractive surgery beyond 2020.

Authors:  Marcus Ang; Damien Gatinel; Dan Z Reinstein; Erik Mertens; Jorge L Alió Del Barrio; Jorge L Alió
Journal:  Eye (Lond)       Date:  2020-07-24       Impact factor: 3.775

6.  Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position.

Authors:  David P Piñero; Vicente J Camps; MarIa L Ramón; Verónica Mateo; Rafael J Pérez-CambrodI
Journal:  Indian J Ophthalmol       Date:  2015-05       Impact factor: 1.848

7.  Lens Epithelial Cells Initiate an Inflammatory Response Following Cataract Surgery.

Authors:  Jian Jiang; Mahbubul H Shihan; Yan Wang; Melinda K Duncan
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-10-01       Impact factor: 4.799

Review 8.  Refractive lens exchange in modern practice: when and when not to do it?

Authors:  Jorge L Alió; Andrzej Grzybowski; Dorota Romaniuk
Journal:  Eye Vis (Lond)       Date:  2014-12-10

Review 9.  Accommodative intraocular lenses: where are we and where we are going.

Authors:  Jorge L Alió; Jorge L Alió Del Barrio; Alfredo Vega-Estrada
Journal:  Eye Vis (Lond)       Date:  2017-06-26

Review 10.  Correction of presbyopia: An integrated update for the practical surgeon.

Authors:  Marie Joan Therese D Balgos; Veronica Vargas; Jorge L Alió
Journal:  Taiwan J Ophthalmol       Date:  2018 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.