Literature DB >> 19780320

Experimental characterization and mitigation of specimen charging on thin films with one conducting layer.

Kenneth H Downing1, M R McCartney, Robert M Glaeser.   

Abstract

Specimen charging may be one of the most significant factors that contribute to the high variability and generally low quality of images in cryo-electron microscopy. Understanding the nature of specimen charging can help in devising methods to reduce or even avoid its effects and thus improve the rate of data collection as well as the quality of the data. We describe a series of experiments that help to characterize the charging phenomenon, which has been termed the Berriman effect. The pattern of buildup and disappearance of the charge pattern has led to several suggestions for how to alleviate the effect. Experiments are described that demonstrate the feasibility of such charge mitigation.

Mesh:

Substances:

Year:  2004        PMID: 19780320     DOI: 10.1017/s143192760404067x

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  9 in total

1.  Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

Authors:  Michael Marko; Ardean Leith; Chyongere Hsieh; Radostin Danev
Journal:  J Struct Biol       Date:  2011-01-25       Impact factor: 2.867

2.  Volta potential phase plate for in-focus phase contrast transmission electron microscopy.

Authors:  Radostin Danev; Bart Buijsse; Maryam Khoshouei; Jürgen M Plitzko; Wolfgang Baumeister
Journal:  Proc Natl Acad Sci U S A       Date:  2014-10-20       Impact factor: 11.205

3.  The surface of evaporated carbon films is an insulating, high-bandgap material.

Authors:  David M Larson; Kenneth H Downing; Robert M Glaeser
Journal:  J Struct Biol       Date:  2011-02-19       Impact factor: 2.867

4.  Deformed grids for single-particle cryo-electron microscopy of specimens exhibiting a preferred orientation.

Authors:  Ying Liu; Xing Meng; Zheng Liu
Journal:  J Struct Biol       Date:  2013-03-26       Impact factor: 2.867

5.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Authors:  Radostin Danev; Robert M Glaeser; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2008-12-11       Impact factor: 2.689

Review 6.  The use of trehalose in the preparation of specimens for molecular electron microscopy.

Authors:  Po-Lin Chiu; Deborah F Kelly; Thomas Walz
Journal:  Micron       Date:  2011-06-25       Impact factor: 2.251

7.  Charge accumulation in electron cryomicroscopy.

Authors:  Christopher J Russo; Richard Henderson
Journal:  Ultramicroscopy       Date:  2018-01-31       Impact factor: 2.689

8.  Microscopic charge fluctuations cause minimal contrast loss in cryoEM.

Authors:  Christopher J Russo; Richard Henderson
Journal:  Ultramicroscopy       Date:  2018-01-31       Impact factor: 2.689

9.  Cryomicroscopy of radiation sensitive specimens on unmodified graphene sheets: reduction of electron-optical effects of charging.

Authors:  Kasim Sader; Martyn Stopps; Lesley J Calder; Peter B Rosenthal
Journal:  J Struct Biol       Date:  2013-05-07       Impact factor: 2.867

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.