Literature DB >> 19779727

Neural response telemetry in patients with the double-array cochlear implant.

Maria Valéria Goffi-Gomez1, Carolina F Abdala, Cristina Gomes Ornelas Peralta, Robinson Koji Tsuji, Rubens Vuono de Brito Neto, Ricardo Ferreira Bento.   

Abstract

This study aimed to evaluate the neural response in double-array cochlear implant as well as to describe the refractory recovery and the spread of excitation functions. In a prospective study 11 patients were implanted with the double-array cochlear implant. Neural response telemetry (NRT) was performed intra-operatively. NRT threshold could be registered in 6 of the 11 patients, at least in one electrode. The remaining five patients did not show measurable neural response intra-operatively. It was noted that although recovery and spread of excitation functions could be recorded in all the tested electrodes with measurable neural responses, the responses were shown to be different from the usual register in patients with other etiologies.

Entities:  

Mesh:

Year:  2009        PMID: 19779727     DOI: 10.1007/s00405-009-1092-7

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  18 in total

1.  The results in patients implanted with the nucleus double array cochlear implant: pitch discrimination and auditory performance.

Authors:  Th Lenarz; A Büchner; C Tasche; T Cristofoli; A Lesinski-Schiedat; E V Wallenberg; R D Battmer; P A Busby; C Frohne
Journal:  Ear Hear       Date:  2002-02       Impact factor: 3.570

2.  Measurement of the electrically evoked compound action potential via a neural response telemetry system.

Authors:  Norbert Dillier; Wai Kong Lai; Bengt Almqvist; Carolin Frohne; Joachim Müller-Deile; Matthias Stecker; Ernst von Wallenberg
Journal:  Ann Otol Rhinol Laryngol       Date:  2002-05       Impact factor: 1.547

3.  Electrode configuration influences action potential initiation site and ensemble stochastic response properties.

Authors:  Charles A Miller; Paul J Abbas; Kirill V Nourski; Ning Hu; Barbara K Robinson
Journal:  Hear Res       Date:  2003-01       Impact factor: 3.208

4.  Channel interaction in cochlear implant users evaluated using the electrically evoked compound action potential.

Authors:  Paul J Abbas; Michelle L Hughes; Carolyn J Brown; Charles A Miller; Heather South
Journal:  Audiol Neurootol       Date:  2004 Jul-Aug       Impact factor: 1.854

5.  Effects of central nervous system residua on cochlear implant results in children deafened by meningitis.

Authors:  Howard W Francis; Margaret B Pulsifer; Jill Chinnici; Robert Nutt; Holly S Venick; Jennifer D Yeagle; John K Niparko
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2004-05

6.  Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant system.

Authors:  D Cafarelli Dees; N Dillier; W K Lai; E von Wallenberg; B van Dijk; F Akdas; M Aksit; C Batman; A Beynon; S Burdo; J-M Chanal; L Collet; M Conway; C Coudert; L Craddock; H Cullington; N Deggouj; B Fraysse; S Grabel; J Kiefer; J G Kiss; T Lenarz; A Mair; S Maune; J Müller-Deile; J-P Piron; S Razza; C Tasche; H Thai-Van; F Toth; E Truy; A Uziel; G F Smoorenburg
Journal:  Audiol Neurootol       Date:  2005-01-12       Impact factor: 1.854

7.  A pathway for information transmission to the ear.

Authors:  R F Bento; A Miniti; T G Sanchez; A Leiner; C A Nunes
Journal:  Ear Nose Throat J       Date:  1995-09       Impact factor: 1.697

8.  An improved method of reducing stimulus artifact in the electrically evoked whole-nerve potential.

Authors:  C A Miller; P J Abbas; C J Brown
Journal:  Ear Hear       Date:  2000-08       Impact factor: 3.570

9.  Cochlear ossification after meningitis.

Authors:  P R Axon; R H Temple; S R Saeed; R T Ramsden
Journal:  Am J Otol       Date:  1998-11

10.  Neural response telemetry measures in patients implanted with Nucleus 24.

Authors:  Mariana Cardoso Guedes; Rubens V Brito Neto; Maria Valéria S Goffi Gomez; Sandra B Giorgi Sant'Anna; Cristina G Ornelas Peralta; Arthur Menino Castilho; Ricardo Ferreira Bento
Journal:  Braz J Otorhinolaryngol       Date:  2006-03-31
View more
  2 in total

1.  Cochlear implants and bacterial meningitis: A speech recognition study in paired samples.

Authors:  Rubens de Brito; Aline Gomes Bittencourt; Maria Valéria Goffi-Gomez; Ana Tereza Magalhães; Paola Samuel; Robinson Koji Tsuji; Ricardo Ferreira Bento
Journal:  Int Arch Otorhinolaryngol       Date:  2013-01

2.  Use of remote control in the intraoperative telemetry of cochlear implant: multicentric study.

Authors:  Liege Franzini Tanamati; Maria Valéria Schmidt Goffi-Gomez; Lilian Ferreira Muniz; Paola Angélica Samuel; Gislaine Richter Minhoto Wiemes; Daniele Penna Lima; Sílvia Badur Curi; Lucia Cristina Onuki; Carla Fortunato Queiroz; Ana Karla Bigois Capistrano; Adriane Lima Mortari Moret; Márcia Yuri Tsumura Kimura; Valeria Oyanguren; Herbert Mauch
Journal:  Braz J Otorhinolaryngol       Date:  2018-05-18
  2 in total