Literature DB >> 24293950

Comparison between external fixators and fixed-angle volar-locking plates in the treatment of distal radius fractures.

Alberto Agustín Jorge-Mora1, David Cecilia-López, Victor Rodríguez-Vega, Laura Suárez-Arias, Eva Andrés-Esteban, Miguel Ángel Porras-Moreno, Carlos Resines-Erasun.   

Abstract

Distal radius fractures are a common disorder in industrialized nations associated with osteoporosis, with a reported incidence of two fractures per thousand patients per year. We performed a retrospective study comparing two sets of 40 patients, with fracture of the distal radius treated with Penning external fixator, compared to 40 patients treated with fixed-angle volar-locking plate (Plate Depuy ® DVR), with the objective of finding differences between both treatment methods in anatomical values, functional outcomes and complication rates. All fractures were classified according to the AO classification. Postero-anterior and lateral radiographs of the wrist were taken after fracture, after surgery and at 6 months after surgery. We also assessed functional outcome. Minimum follow up was of 10 months. We compared complications between both groups. In the group of patients treated with fixed-angle volar-locked plate, radiological results are found to be closer to the anatomical references. Final outcomes revealed similar functional scores between both groups. The complications rate was statistically higher in the group of patients who underwent external fixation. In the fixed-angle volar-locked plate group, most of complications were related to patient discomfort due to the volar-locking plate.

Entities:  

Keywords:  Complications; External-fixator; Fracture; Plate; Radius

Year:  2012        PMID: 24293950      PMCID: PMC3509289          DOI: 10.1007/s12593-012-0072-0

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  16 in total

1.  Fractures of the distal end of the radius. A clinical and statistical study of end results.

Authors:  A LIDSTROM
Journal:  Acta Orthop Scand Suppl       Date:  1959

Review 2.  A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures.

Authors:  Zvi Margaliot; Steven C Haase; Sandra V Kotsis; H Myra Kim; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2005-11       Impact factor: 2.230

3.  Treatment of distal radius fractures.

Authors:  David M Lichtman; Randipsingh R Bindra; Martin I Boyer; Matthew D Putnam; David Ring; David J Slutsky; John S Taras; William C Watters; Michael J Goldberg; Michael Keith; Charles M Turkelson; Janet L Wies; Robert H Haralson; Kevin M Boyer; Kristin Hitchcock; Laura Raymond
Journal:  J Am Acad Orthop Surg       Date:  2010-03       Impact factor: 3.020

4.  Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation.

Authors:  H Kapoor; A Agarwal; B K Dhaon
Journal:  Injury       Date:  2000-03       Impact factor: 2.586

5.  Acute compartment syndrome. Who is at risk?

Authors:  M M McQueen; P Gaston; C M Court-Brown
Journal:  J Bone Joint Surg Br       Date:  2000-03

6.  Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study.

Authors:  Frankie Leung; Yuan-Kun Tu; Winston Y C Chew; Shew-Ping Chow
Journal:  J Bone Joint Surg Am       Date:  2008-01       Impact factor: 5.284

7.  A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study.

Authors:  Markus Windolf; Karsten Schwieger; Ben Ockert; Jesse B Jupiter; Georg Gradl
Journal:  Injury       Date:  2009-10-09       Impact factor: 2.586

8.  Fixation of dorsally displaced distal radius fractures with volar plate.

Authors:  Ahmed Y Othman
Journal:  J Trauma       Date:  2009-05

9.  Displaced distal radial fractures treated using volar locking plates: maintenance of normal anatomy.

Authors:  Iain Stevenson; Carol A Carnegie; Eva M Christie; Kapil Kumar; Alan J Johnstone
Journal:  J Trauma       Date:  2009-09

10.  Intra-articular fractures of the distal radius: a prospective randomised controlled trial comparing static bridging and dynamic non-bridging external fixation.

Authors:  J Krishnan; A E R Wigg; R W Walker; J Slavotinek
Journal:  J Hand Surg Br       Date:  2003-10
View more
  3 in total

1.  The Declining Use of Wrist-Spanning External Fixators.

Authors:  Venus Vakhshori; Alexis D Rounds; Nathanael Heckmann; Ali Azad; Jessica M Intravia; Santano Rosario; Milan Stevanovic; Alidad Ghiassi
Journal:  Hand (N Y)       Date:  2018-08-07

Review 2.  Review of Internal Radiocarpal Distraction Plating for Distal Radius Fracture Fixation.

Authors:  Venus Vakhshori; Ram Kiran Alluri; Milan Stevanovic; Alidad Ghiassi
Journal:  Hand (N Y)       Date:  2018-07-13

3.  Is volar locking plate superior to external fixation for distal radius fractures? A comprehensive meta-analysis.

Authors:  Jie Wang; Yandong Lu; Yujie Cui; Xuelei Wei; Jie Sun
Journal:  Acta Orthop Traumatol Turc       Date:  2018-06-29       Impact factor: 1.511

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.