Literature DB >> 19704327

The aortic root: comparison of measurements from ECG-gated CT angiography with transthoracic echocardiography.

Iclal Ocak1, Joan M Lacomis, Christopher R Deible, Karen Pealer, Yoav Parag, Friedrich Knollmann.   

Abstract

PURPOSE: The purpose of this study was to compare the measurements of the aortic root obtained from electrocardiographically (ECG)-gated computed tomography (CT) angiography (CTA) to the measurements obtained from transthoracic echocardiography (TTE).
MATERIALS AND METHODS: This was a retrospective study in a patient population scanned at our institution between December 2005 and January 2007 with retrospectively ECG-gated CTA. ECG-gated CTA was performed with a 64-section helical CT scanner (Light speed, VCT, GE, Milwaukee, WI). Sixty-eight patients; 51 men and 17 women were included in this study. Aortic root diameters were measured by using double oblique reconstruction from axial source images. The TTE measurements of the aortic root were obtained from the reports that were performed within 2 months of CTA.
RESULTS: The average aortic root diameter measured by TTE was 33+/-4.1 mm; on CTA it was 36.9+/-3.8 mm. The median difference between the 2 measurements was 3.9 mm which was significant (P<0.0001). In patients whose aortic root measurements with CTA were normal, the TTE measurements were also normal. However, in the group of patients with dilated aortic roots by CTA, TTE measurements were significantly lower and many were normal. In the group of patients with dilated aortic root by TTE, the CTA measurements of the aortic root were similarly increased.
CONCLUSIONS: Retrospective comparison of TTE and CTA measurements of the aortic root reveal that TTE measurements are substantially lower or even normal in patients found to have dilated aortic root by CTA.

Entities:  

Mesh:

Year:  2009        PMID: 19704327     DOI: 10.1097/RTI.0b013e31819f9369

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  12 in total

1.  Measurement of the ascending aorta diameter in patients with severe bicuspid and tricuspid aortic valve stenosis using dual-source computed tomography coronary angiography.

Authors:  Jee Young Son; Sung Min Ko; Jin Woo Choi; Meong Gun Song; Hweung Kon Hwang; Sook Jin Lee; Joon-Won Kang
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-19       Impact factor: 2.357

2.  A comparative analysis of ECG-gated steady state free precession magnetic resonance imaging versus transthoracic echocardiography for evaluation of aortic root dimensions.

Authors:  Edward T D Hoey; Vijaya Pakala; Rahil H Kassamali; Arul Ganeshan
Journal:  Quant Imaging Med Surg       Date:  2014-10

3.  Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology.

Authors:  Hong Ju Shin; Je Kyoun Shin; Hyun Kun Chee; Jun Suk Kim; Sung Min Ko
Journal:  Eur Radiol       Date:  2015-01-16       Impact factor: 5.315

Review 4.  Multi-detector CT angiography of the aortic valve-Part 1: anatomy, technique and systematic approach to interpretation.

Authors:  Edward T D Hoey; Arul Ganeshan
Journal:  Quant Imaging Med Surg       Date:  2014-08

5.  Aortic root dimensions are predominantly determined by genetic factors: a classical twin study.

Authors:  Csilla Celeng; Márton Kolossváry; Attila Kovács; Andrea Ágnes Molnár; Bálint Szilveszter; Tamás Horváth; Mihály Károlyi; Ádám L Jermendy; Ádám D Tárnoki; Dávid L Tárnoki; Júlia Karády; Szilard Voros; György Jermendy; Béla Merkely; Pál Maurovich-Horvat
Journal:  Eur Radiol       Date:  2016-09-22       Impact factor: 5.315

6.  The usefulness of multidetector computed tomographic angiography for the diagnosis of Marfan syndrome by Ghent criteria.

Authors:  Gwan Hyeop Sohn; Shin Yi Jang; Ju Ryoung Moon; Jeong Hoon Yang; Kiick Sung; Chang-Seok Ki; Jae K Oh; Yeon Hyeon Choe; Duk-Kyung Kim
Journal:  Int J Cardiovasc Imaging       Date:  2011-04-19       Impact factor: 2.357

Review 7.  Aortic root disease in athletes: aortic root dilation, anomalous coronary artery, bicuspid aortic valve, and Marfan's syndrome.

Authors:  Eugene Sun Yim
Journal:  Sports Med       Date:  2013-08       Impact factor: 11.136

8.  Proximal thoracic aortic diameters: transesophageal-echocardiography- versus computed-tomography-derived measurements.

Authors:  Prachi P Agarwal; Peter S Liu; Peter Hagan; Anna M Booher; Kuanwong Watcharotone; Leslie E Quint
Journal:  Clin Imaging       Date:  2015-10-27       Impact factor: 1.605

9.  The American Association for Thoracic Surgery consensus guidelines on bicuspid aortic valve-related aortopathy: Full online-only version.

Authors:  Michael A Borger; Paul W M Fedak; Elizabeth H Stephens; Thomas G Gleason; Evaldas Girdauskas; John S Ikonomidis; Ali Khoynezhad; Samuel C Siu; Subodh Verma; Michael D Hope; Duke E Cameron; Donald F Hammer; Joseph S Coselli; Marc R Moon; Thoralf M Sundt; Alex J Barker; Michael Markl; Alessandro Della Corte; Hector I Michelena; John A Elefteriades
Journal:  J Thorac Cardiovasc Surg       Date:  2018-08       Impact factor: 5.209

10.  Aortic root measurement on CT: linear dimensions, aortic root area and comparison with echocardiography. A retrospective cross sectional study.

Authors:  Kai'En Leong; Henry Knipe; Simon Binny; Heather Pascoe; Nathan Better; Francesca Langenberg; Elaine Lui; Subodh B Joshi
Journal:  Br J Radiol       Date:  2021-03-08       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.