Literature DB >> 19701447

A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT.

Jianguo Qian1, Eric L Bradley, Stan Majewski, Vladimir Popov, Margaret S Saha, Mark F Smith, Andrew G Weisenberger, Robert E Welsh.   

Abstract

We have designed and built a small animal single photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ~35 keV photons from the decay of (125)I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm(3)/pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five 1 mm diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications.

Entities:  

Year:  2008        PMID: 19701447      PMCID: PMC2577056          DOI: 10.1016/j.nima.2008.05.061

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  10 in total

1.  Determination of mechanical and electronic shifts for pinhole SPECT using a single point source.

Authors:  S D Metzler; K L Greer; R J Jaszczak
Journal:  IEEE Trans Med Imaging       Date:  2005-03       Impact factor: 10.048

2.  Design and simulation of a high-resolution stationary SPECT system for small animals.

Authors:  Freek J Beekman; Brendan Vastenhouw
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

3.  First results from the high-resolution mouseSPECT annular scintillation camera.

Authors:  Andrew L Goertzen; Douglas W Jones; Jurgen Seidel; King Li; Michael V Green
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

4.  Molecular imaging of small animals with a triple-head SPECT system using pinhole collimation.

Authors:  S D Metzler; R J Jaszczak; N H Patil; S Vemulapalli; G Akabani; B B Chin
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

5.  Maximum likelihood reconstruction for pinhole SPECT with a displaced center-of-rotation.

Authors:  J Li; R J Jaszczak; R E Coleman
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

6.  Bayesian reconstructions from emission tomography data using a modified EM algorithm.

Authors:  P J Green
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

7.  U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice.

Authors:  Freek J Beekman; Frans van der Have; Brendan Vastenhouw; Annemarie J A van der Linden; Peter P van Rijk; J Peter H Burbach; Marten P Smidt
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

8.  Optimum dimensions of parallel-hole, multi-aperture collimators for gamma-ray cameras.

Authors:  E L Keller
Journal:  J Nucl Med       Date:  1968-06       Impact factor: 10.057

9.  Fast calculation of the exact radiological path for a three-dimensional CT array.

Authors:  R L Siddon
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

10.  A gamma camera re-evaluation of potassium iodide blocking efficiency in mice.

Authors:  William T Hammond; Eric L Bradley; Robert E Welsh; Jianguo Qian; Andrew G Weisenberger; Mark F Smith; Stan Majewski; Margaret S Saha
Journal:  Health Phys       Date:  2007-04       Impact factor: 1.316

  10 in total
  3 in total

Review 1.  Novel delivery strategies for glioblastoma.

Authors:  Jiangbing Zhou; Kofi-Buaku Atsina; Benjamin T Himes; Garth W Strohbehn; W Mark Saltzman
Journal:  Cancer J       Date:  2012 Jan-Feb       Impact factor: 3.360

2.  Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

Authors:  James Bowsher; Susu Yan; Justin Roper; William Giles; Fang-Fang Yin
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

3.  Feasibility of whole-body functional mouse imaging using helical pinhole SPECT.

Authors:  Scott D Metzler; Sreekanth Vemulapalli; Ronald J Jaszczak; Gamal Akabani; Bennett B Chin
Journal:  Mol Imaging Biol       Date:  2009-06-12       Impact factor: 3.488

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.