Literature DB >> 15754986

Determination of mechanical and electronic shifts for pinhole SPECT using a single point source.

S D Metzler1, K L Greer, R J Jaszczak.   

Abstract

The effects of uncompensated electronic and mechanical shifts may compromise the resolution of pinhole single photon emission computed tomography. The resolution degradation due to uncompensated shifts is estimated through simulated data. A method for determining the transverse mechanical and axial electronic shifts is described and evaluated. This method assumes that the tilt of the detector and the radius of rotation (ROR) are previously determined using another method. When this assumption is made, it is possible to determine the rest of the calibration parameters using a single point source. A method that determines the electronic and mechanical shifts as well as the tilt has been previously described; this method requires three point sources. It may be reasonable in most circumstances to calibrate tilt much less frequently than the mechanical shifts since the tilt is a property of the scanner whereas the mechanical shift may change every time the collimator is replaced. An alternative method for determining the ROR may also be used. Lastly, we take the view that the transverse electronic shift and the focal length change slowly and find these parameters independently.

Entities:  

Mesh:

Year:  2005        PMID: 15754986     DOI: 10.1109/tmi.2004.842456

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

Review 1.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Authors:  Freek Beekman; Frans van der Have
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

2.  Geometric characterization of multi-axis multi-pinhole SPECT.

Authors:  Frank P DiFilippo
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  A line-source method for aligning on-board and other pinhole SPECT systems.

Authors:  Susu Yan; James Bowsher; Fang-Fang Yin
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Design of a dual-resolution collimator for preclinical cardiac SPECT with a stationary triple-detector system.

Authors:  Stephen C Moore; Mi-Ae Park; Zhe Liu; Morgan C Lyon; Lindsay C Johnson; Victor H Lushear; James G Westberg; Scott D Metzler
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

5.  Depth-of-Interaction Compensation Using a Focused-Cut Scintillator for a Pinhole Gamma Camera.

Authors:  Fares Alhassen; Haris Kudrolli; Bipin Singh; Sangtaek Kim; Youngho Seo; Robert G Gould; Vivek V Nagarkar
Journal:  IEEE Trans Nucl Sci       Date:  2011-06-01       Impact factor: 1.679

6.  Slit-Slat and Multislit-Slat Collimator Design and Experimentally Acquired Phantom Images from a Rotating Prototype.

Authors:  Scott D Metzler; Roberto Accorsi; Ahmet S Ayan; Ronald J Jaszczak
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-01       Impact factor: 1.679

7.  LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation.

Authors:  Yusheng Li; Samuel Matej; Joel S Karp; Scott D Metzler
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

8.  A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT.

Authors:  Jianguo Qian; Eric L Bradley; Stan Majewski; Vladimir Popov; Margaret S Saha; Mark F Smith; Andrew G Weisenberger; Robert E Welsh
Journal:  Nucl Instrum Methods Phys Res A       Date:  2008-08-21       Impact factor: 1.455

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.