Literature DB >> 19696469

A post-scan method for correcting artefacts of slow geometry changes during micro-tomographic scans.

P L Salmon1, X Liu, A Sasov.   

Abstract

Micro-CT imaging of objects at very high magnification runs into the problem of small geometric movements of the x-ray emission spot relative to the object, thermally induced or otherwise, causing magnified shifts in the projection images during scanning. This produces movement artefacts in the reconstructed images. Here a technique is described to correct such movements by adding a short reference scan at the end of a high magnification scan, with a very large rotation step. Where geometry changes during a scan are slow, such movements can be considered minimal during this very short "post-scan". Registration of the post-scan images with corresponding images in the main scan allow X/Y pixel shifts in the projection images associated with the geometry movement to be calculated, and corrected during reconstruction. This post-scan correction method was applied here to scans of three small objects, all with a voxel size less than one micron, in a desktop micro-CT and a nano-CT scanner. The method substantially reduced movement artefacts from the reconstructed images, improving image quality and resolution. Where the geometry movement results largely from thermal movement of the x-ray micro-focus emission spot, the post-scan method allows the reconstruction of the spatio-temporal trajectory of this spot movement.

Mesh:

Substances:

Year:  2009        PMID: 19696469     DOI: 10.3233/XST-2009-0220

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  6 in total

1.  Dose reduction with adaptive bolus chasing computed tomography angiography.

Authors:  Zhijun Cai; Er-Wei Bai; Ge Wang; Melhem J Sharafuddin; Hicham T Abada
Journal:  J Xray Sci Technol       Date:  2010       Impact factor: 1.535

2.  Micro-computed tomography as a platform for exploring Drosophila development.

Authors:  Todd A Schoborg; Samantha L Smith; Lauren N Smith; H Douglas Morris; Nasser M Rusan
Journal:  Development       Date:  2019-12-11       Impact factor: 6.868

3.  Comparative hard x-ray tomography for virtual histology of zebrafish larva, human tooth cementum, and porcine nerve.

Authors:  Alexandra Migga; Georg Schulz; Griffin Rodgers; Melissa Osterwalder; Christine Tanner; Holger Blank; Iwan Jerjen; Phil Salmon; William Twengström; Mario Scheel; Timm Weitkamp; Christian M Schlepütz; Jan S Bolten; Jörg Huwyler; Gerhard Hotz; Srinivas Madduri; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2022-03-31

4.  Host autophagy mediates organ wasting and nutrient mobilization for tumor growth.

Authors:  Petter Holland; Todd Andrew Schoborg; Rojyar Khezri; Ifat Abramovich; Szabolcs Takáts; Caroline Dillard; Ashish Jain; Fergal O'Farrell; Sebastian Wolfgang Schultz; William M Hagopian; Eduardo Martin Quintana; Rachel Ng; Nadja Sandra Katheder; Mohammed Mahidur Rahman; José Gerardo Teles Reis; Andreas Brech; Heinrich Jasper; Nasser M Rusan; Anne Hope Jahren; Eyal Gottlieb; Tor Erik Rusten
Journal:  EMBO J       Date:  2021-07-26       Impact factor: 14.012

5.  Computed tomography with segmentation and quantification of individual organs in a D. melanogaster tumor model.

Authors:  Petter Holland; Eduardo Martin Quintana; Rojyar Khezri; Todd Andrew Schoborg; Tor Erik Rusten
Journal:  Sci Rep       Date:  2022-02-08       Impact factor: 4.379

6.  Multiscale Dense U-Net: A Fast Correction Method for Thermal Drift Artifacts in Laboratory NanoCT Scans of Semi-Conductor Chips.

Authors:  Mengnan Liu; Yu Han; Xiaoqi Xi; Linlin Zhu; Shuangzhan Yang; Siyu Tan; Jian Chen; Lei Li; Bin Yan
Journal:  Entropy (Basel)       Date:  2022-07-13       Impact factor: 2.738

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.